revolution easy ESUK 2016 fn

Download Report

Transcript revolution easy ESUK 2016 fn

Revolution easy
Cargador de baterías trifásico
Three-phase battery charger
Versione Wa
Wa curve
El cargador de baterías de la serie Revolution easy es apropiado para cargar baterías de tracción y de encendido al plomo
de media-grande capacidad. Fue generado por la experiencia cuarentenal de los socios fundadores en el campo de los
cargadores de baterías y plurianual aplicación de los sistemas de control mediante microprocesadores, que manteniendo
constantemente bajo control los parámetros fundamentales, salvaguardan el correcto funcionamiento y por lo tanto la
duración de las baterías.
The battery chargers of the Revolution easy series are designed to recharge medium - large capacity traction and start
lead-acid batteries and are the result of the founding members’ fourty-year experience in the field of battery chargers, in
the application of microprocessor control systems which constantly monitorize the basic parameters to assure a correct
operation and therefore safeguard the battery’s life.
• Carga con corriente decreciente intervención de la carga
final ajustable de 2,35 hasta 2,40 V/el
• Carga final controlada a tiempo.
• Tiempo de carga previsto (carga igualada no incluida) 9h / 11h
• Carga igualada (carga fin de semana) a llamada inicio
después 55’ desde el final de la carga
• Duración de la fase de carga igualada cada hora 5’ (se repite
por 48 horas)
• Estima para determinar el tamaño del cargador de baterías
apropiado: 16A por cada 100 Ah de batería (Ej. batería 500 Ah:
16Ax5 = 80A
• Charge at decreasing current with intervention of the final
charge at 2.40 V/cell
• Final charge with timed control 9h / 11h
• Fixed charging time (equalization charge excluded)
• Equalization charge (week-end charge) to be recalled. It will
start after 55’ from charge end
• Duration of equalized charging phase: each hour 5’ (repeated
for 48 hours)
• Calculation to determine the size of suitable battery charge:
16A for every 100 Ah of the battery (e.g. 500 Ah battery: 16Ax5
= 80A
Security and an environmental close-up
(Global warming, CO2 reduction)
Con arreglo a las directivas 89/336/CEE y 72/23/ CEE y marcad
.
Conformity to the directives 89/336/CEE and 72/23/CEE
marking.
Los datos de este catálogo deben entenderse como simplemente orientativos y pueden ser modificados sin aviso previo.
The company reserves the right to change the specifications of its products without prior notice and such change would render the pubblications inaccurate.
Rev.:2-2016
ISO 9001
Cargador de baterías trifásico
Three-phase battery charger
Características técnicas
Technical Characteristics
• Alimentación trifásica 400V o 230V (con posibilidad de pedir tensiones
diferentes de la estándar) con posibilidad de regulación ± 5%.
• Control con microprocesores mediante centralita programable mediante dipswitch 24V-36V-48V.
• Contactor tripolar bobina 220V.
• Fusible en c.c. salida rectificador.
• Puente rectificador con filtros antimolestias.
• Prueba rápida para el control de las funciones y de los tiempos de carga.
• Carga igualada automática.
• Circuito electrónico probado en laboratorio para alcanzar la conformidad a la
directiva sobre la compatibilidad electromagnética y el marcado CE.
• Desconexión automática del cargador de baterías con batería desconectada.
• Carga igualada a tiempo.
• Carga decreciente (versión WA) con tiempo de recarga en 9÷11 horas.
• Protecciones térmicas en los tres adevandos primarios.
• Montaje modular sobre zócalo de acero galvanizado.
• Laquedo con polvo epoxídico en horno.
• Color estándar AZUL RAL 2004.
• Color personalizado opcional.
• Color y serigrafía personalizados opcionales.
• Material de equipo: cable red, cables batería con montaje clavija red y
conectores batería a petición.
• Cables salida batería (+)Rojo (-)Negro.
• Cable entrada red.
• 3x220-400V three-phase supply - adjustable ± 5% with possibility to
request voltage different from the standard ones.
• Microprocessor control with dip-switch programmable gearcase 24V - 36V 48V.
• 220V coil three-pole contactor.
• D.C. fuse on rectifier output.
• Rectifier bridge with snubber protection.
• Short check of functions and times.
• Automatic equalized charg.
• Lab tested electronic circuit conforming to the directive on electromagnetic
compatibility and CE marking.
• Automatic disconnection of battery charger due to battery disconnection.
• Equalization charge based on time.
• Charging with decreasing current (Wa characteristic): 9÷11 h charging time.
• Transformer thermal protection.
• Modular installation on galvanized steel base.
• Sheet steel case with modular panels.
• Epoxy powder coating, oven-baked.
• Standard colour: RAL 5003 BLUE.
• Option: custom-made colour.
• Custom-made logo and silk-screen printing.
• Mains input and d.c. output polarized cables.
• Complete with mains and battery cables; assembly of plugs and battery
connectors on request.
TERNSIÓN/CORRIENTE
V
O
L
T
A
G
E/
C
U
R
R
E
NT
2
4
V
3
6
V
4
8
V
4
0
A
6
0
A
8
0
A
1
0
0
A
1
2
0
A
4
0
A
6
0
A
8
0
A
1
0
0
A
1
2
0
A
4
0
A
6
0
A
8
0
A
1
0
0
A
1
2
0
A
C
Ó
D
I
G
O
C
A
P
A
C
I
D
A
D
S
U
MI
NI
S
T
R
O
MO
D
E
L
O
P
O
WE
R
G
E
N
B
A
T
E
R
Í
A
(
A
h
)
D
EE
NE
R
G
Í
A
P
O
WE
R
G
E
N
B
A
T
T
E
R
Y
P
O
WE
R
MO
D
E
L
C
O
D
E
C
A
P
A
C
I
T
Y(
A
h
)
S
U
P
P
L
Y
E
E
2
4
4
0
T
MA
X2
4
0
E
E
2
4
6
0
T
MA
X3
6
0
E
E
2
4
8
0
T
MA
X4
8
0
R
E
V
O
L
U
T
I
O
NE
A
S
Y
4
0
0+
/
5
%
E
E
2
4
1
0
0
T
MA
X6
0
0
E
E
2
4
1
2
0
T
MA
X7
2
0
E
E
3
6
4
0
T
MA
X2
4
0
E
E
3
6
6
0
T
MA
X3
6
0
E
E
3
6
8
0
T
MA
X4
8
0
R
E
V
O
L
U
T
I
O
NE
A
S
Y
4
0
0+
/
5
%
E
E
3
6
1
0
0
T
MA
X6
0
0
E
E
3
6
1
2
0
T
MA
X7
2
0
E
E
4
8
4
0
T
MA
X2
4
0
E
E
4
8
6
0
T
MA
X3
6
0
E
E
4
8
8
0
T
MA
X4
8
0
R
E
V
O
L
U
T
I
O
NE
A
S
Y
4
0
0+
/
5
%
E
E
4
8
1
0
0
T
MA
X6
0
0
E
E
4
8
1
2
0
T
MA
X7
2
0
E
Q
U
I
P
A
D
OC
O
NC
A
B
L
E
SD
EE
NT
R
A
D
AR
E
DYC
A
B
L
E
SP
O
L
A
R
I
Z
A
D
O
SD
EB
A
T
E
R
Í
A
E
Q
U
I
P
P
E
DWI
T
HP
O
WE
RC
O
R
DA
NDB
A
T
T
E
R
YC
A
B
L
E
D
I
ME
NS
I
O
NE
S
E
nmm
D
I
ME
NS
I
O
NS
I
nmm
5
0
0
x
3
6
0
x
4
5
0
5
0
0
x
3
6
0
x
4
5
0
5
0
0
x
3
6
0
x
4
5
0
También disponible en versión monofásica - Single phase also available
Curvas de carga “ wa ” (din 41774)
“ Wa ” characteristic (din 41774)
Tamaño armario - Box dimensions
Trifase - Three phase
360
450
5 min
55min 55min
500
La curva de carga de este modelo es la Wa (carga a corriente decreciente), conforme con la Directiva DIN41774. La curva de carga Wa está caracterizada por una evolución decreciente de la corriente de carga a medida
que aumenta la tensión de batería, por lo tanto tiene potencia constante. Para obtener una carga apropiada de la batería, el cargador de baterías tiene que estar en condiciones de facilitar una curva de carga lo más fiel
posible a la curva de carga teórica, que prevé una corriente inicial de carga igual al 16% de la capacidad de la batería y una evolución decreciente, come se indica más arriba. Con este tipo de cargador de baterías con
curva estandar Wa (DIN41774), hay que establecer la corriente de carga necesaria, calculando el 16% de la capacidad en amperio-hora (Ah) de la batería (por ejemplo: para una batería de 600Ah, se utiliza un cargador
de baterías de 100A).
Powergen S.r.l.
Via XXV Aprile, 5 - 52010 Corsalone - Chiusi Della Verna (Arezzo)
phone +39 (0) 575 531015 - Telefax +39 (0) 575 511891
[email protected]
powergen-borri
www.batterychargerpowergen.eu
Los datos de este catálogo deben entenderse como simplemente orientativos y pueden ser modificados sin aviso previo.
The company reserves the right to change the specifications of its products without prior notice and such change would render the pubblications inaccurate.
Rev.:2-2016
The charging curve of this model is the Wa (decreasing current charge) is compliant with DIN 41774. The Wa charging curve, is features by a downward trend of the charging current when the battery voltage increases,
therefore it takes constant power. To obtain a suitable charge of the battery, the charger must be able to provide a charging curve as faithful as possible to the theoretical charging curve, which provides an initial charging
current equal to 16% of the battery capacity, and a declining trend. With this kind of charger with standard curve Wa (DIN 41774), it is necessary to determine the charging current required, by calculating the 16% in
ampere hours (Ah) of the capacity of the battery (for example: for a 600Ah battery, using a charger with 100A).