Capacity Manager v4.x

Download Report

Transcript Capacity Manager v4.x

™
InfraStruxure Management
Software
Eduard Bodor
Senior System Engineer
Romania
All content in this presentation is protected – © 2010 American Power Conversion Corporation
Increasing pressure
… on data center planning and operation
Increasing availability
expectations
Energy efficiency
Uncertain
long-term plans for
capacity or density
Cloud computing
Virtualization
Energy and service
cost control
Dynamic power
variation
Regulatory
requirements
Server
consolidation
In response …
We created – and continue to improve – a new way to plan,
design, install, manage, and maintain data centers
DCPI is….
Data Center Physical Infrastructure
IT
floor
The “white
space”
Covering all levels of
power, cooling, rack
systems, security,
management that
support the IT
equipment
Our complete end-to-end view has profound
implications for AVAILABILITY and EFFICIENCY
APC by Schneider Electric – InfraStruxure Management Software 6.1, What’s New – September 2010
IT is getting boxed-in by power & cooling
● Rack density has doubled every 8 years
since 1992
● Moore’s Law drives increased MIPs
Power density is exploding
● Power density increasing 15% per year
● By 2010, average kW per rack forecast to be 20+ kW
(up from 1 kW in 2000)
● Dense power makes cooling unpredictable and expensive
Moore’s Law is now being limited
by infrastructure!
Source: IDC Report: Aligning IT with Business
4
Key points on energy usage in data centers
● More than 50% of power going into a typical data center goes to the power
and cooling systems – NOT to the IT loads
● The typical 1MW (IT load) data center is continuously wasting about 400kW
or 2,000 tons of coal per year due to poor design (DCiE = 50%, instead of
best-practice 70%)
● Every kW saved in a data center saves about $1,000 per year
● Every kW saved in a data center reduces carbon dioxide emissions by 5
tons per year
● Every kW saved in a data center has a carbon reduction equivalent to
eliminating about 1 car from the road
White
paper
● A 1% improvement in data center infrastructure efficiency (DCiE)
corresponds to approximately 2% reduction in electrical bills
66
5
How that translates into savings
"A small-to-average-sized 1MW US data center
that uses management software to reduce
energy consumption by 10% will save $87,600
per year, or $438,000 over five years (not
including equipment and software investment).
A European datacenter may save $650,000 over
five years (because of higher electricity
prices)."
the 451 group, Eco-Efficient IT, 2009
6
Free IT !
… with lean, smart infrastructure
Smart management can help you …
● Align capacity with demand
At row, rack, and server level
UNMANAGED infrastructure
● Predict fan failure to IT impact
Reduce wasteful excess capacity
● Monitor the physical infrastructure
Instant status and alarms
● Reduce non-IT power consumption
Increase DATA CENTER EFFICIENCY
7
Expanding integrations
• InfraStruxure Operations PRO Pack for Microsoft System Center Virtual
Machine Manager
• Provides insight into how virtual machines relate to physical servers and their
location, automatically migrating virtual machines to secure host environments
enabling customers to maintain Service Level Agreements and view and manage
network health.
• From power failure to IT impact
• Problem:
•The impact of critical power events are not effectively propagated to Virtual Machines
(VMs)
• Solution:
•The critical events are translated into server impact analysis
•VMs at risk are automatically migrated to healthy hosts
• APC Solution requirements
• InfraStruxure Operations & InfraStruxure Capacity v6.1
• InfraStruxure Operations PRO Pack – SKU: SFVMM2008R261 (free download)
APC by Schneider Electric – InfraStruxure Management Software 6.1, What’s New – September 2010
InfraStruxure Operations PRO Pack
System Center
Operation Manager
Location + power path
ISX Operations
= impact analyzer
PRO
Pack
Monitoring software
(ISX Central)
Virtual Machine Manager
Rack 1
Rack 2
Server
Virtual job
UPS a
UPS b
APC by Schneider Electric – InfraStruxure Management Software 6.1, What’s New – September 2010
ISX
Based
Operations
on the impact
communicates
analysis with
from Virtual
ISX
ISX Operations registers alarm and
Operations,
Machine
Monitoring
Manager
software
UPS
the relevant
onthrough
battery
detects
virtual
SCOM
anomality
jobs
PRO
are
calculates an impact analysis.
moved to Pack
healthy hosts.
InfraStruxure Energy Efficiency 1.1
Full insight into current and historical energy efficiency for facilities,
identifying efficiency losses and enabling improved PUE values at
subsystem level.
● PPower dependency editor
● A hierarchical break-down of the power flow from the power enters the
building down to the main PDU, providing an overview of the power path
through the building.
● CCarbon footprint
● Shows the CO2 footprint for each energy sub-system, for instant
measurement of impact on the environment.
Intelligent PUE analytics at subsystem level
APC by Schneider Electric – InfraStruxure Management Software 6.1, What’s New – September 2010
InfraStruxure Operations 6.1
Instant overview of data center operations through inventory
management, PUE calculator, real-time device alarms, and
location-based drill-down
● Network management
● A graphical overview of the data center network paths and their interconnections.
● Blade servers
● Mirror the exact data center setup, by modeling blades within their blade enclosures.
● Expiring license support
● Expiring license support to enable current InfraStruxure Central customers to try out
InfraStruxure Operations for a limited time period
● Download available for customers with a valid software support contract.
● SKU number: SFISXOPS61
Integrated inventory management for full overview of
data center operations
APC by Schneider Electric – InfraStruxure Management Software 6.1, What’s New – September 2010
InfraStruxure Capacity 6.1
Planning and optimizing utilization of actual power, cooling and rack
capacities via shared data center model, enabling efficient equipment
provisioning and right-sizing of your data center.
● Data Center Lab
● For customers to try out future data center changes and view the impact,
without making any changes to their live InfraStruxure Operations application.
Balance IT demand with physical infrastructure supply
APC by Schneider Electric – InfraStruxure Management Software 6.1, What’s New – September 2010
InfraStruxure Management Software
Configuration Services Suite
Implementing the InfraStruxure Management Software Solution
 InfraStruxure Central Configuration
 InfraStruxure Capacity
 Appliance Installation
 InfraStruxure Capacity Policy
 Application Configuration

 InfraStruxure Operations





Catalog Creation
Floor & Rack Layout Creation
IT Device Assessment & Assignment
Power Dependency Configuration
Labeling Service
APC by Schneider Electric – InfraStruxure Management Software 6.1, What’s New – September 2010
Configuration
InfraStruxure Advanced Power
Configuration
 InfraStruxure Post
Configuration Insight
 Post Configuration Knowledge
Transfer for InfraStruxure
Central, InfraStruxure
Operations & InfraStruxure
Capacity
Broad expertise:
Management software & services
“Smart” management system
● Full suite of management software & services for monitoring and control
Schneider Electric is the only DCPI* company offering total
comprehensive management – building automation, IT floor, power
quality
● Ability today to integrate management platforms
● A vision for tomorrow for simplified, integrated management
Remove silos, create energy awareness across entire data center
*DCPI = Data Center Physical Infrastructure