TFT - 대한방사선사협회

Download Report

Transcript TFT - 대한방사선사협회

Fujifilm의 Digital
Mammography 제안
㈜신기사 영업부
목 차
 Fujifilm Digital Mammography
1. FUJI MAMMO DR
“Amulet”
2. FUJI MAMMO CR
“FCR Profect CS”
NEW
1. 최상의 유방암조기검진을 위한
FUJI MAMMO DR
“Amulet”
NEW
Aquisution Work Station
(AWS)
Digital Mammogrphy
AMULET
FUJIFILM Next Generation Digital
Mammography “AMULET”
Current Flat Panel Detector for Mammo DR
Indirect-conversion
FPD(TFT)
Direct-conversion
FPD(TFT)
H사, S사
G사
CsI
a-Se
TFT
TFT
100µm/Pixel
70-85µm/Pixel
・Low sharpness
・Low X-ray conv. efficiency
・High sharpness
・High X-ray conv. efficiency
・Efficient workflow
・Inefficient workflow
Problem of current FPD(TFT) Reading
Data line
■Read-out
Gate line
with TFT
・The Matrix Circuit Structure
causes Electric Noise.
・The Higher Definition causes
the lower Conv. Efficiency.
As the Pixel gets smaller…….
Noise increase. & DQE is reduced.
FUJI FILM’s New Flat Panel Detector
by Direct Optical Switching Tech.
NEW
■ Double-layer a-Se -- High X-ray conversion efficiency
■ Switched by the light without TFT -- Lower Noise & High DQE
■ High Definition Image with 50μm pixel pitch.
■ Quick erasure of remaining electrons by erasure light.
Next Generation FPD
Double-layer a-Se
By Direct Optical Switching Tech.
Upper electrode
Upper a-Se
X-ray absorption layer
Lower a-Se
Read out layer
Read out electrode
Narrow beam
Double-layer a-Se
High absorption of X-ray
Switched by beam
Low noise & High DQE
without TFT
Performance of the Fujifilm new Detector
X-Ray exposure
■ Direct conversion
&
■ a-Se double layer
&
■ Direct Optical
Switching
Direct conversion of X-ray to electron
Light exposure to Switching layer
Read-out of electrons
Erasure light exposure
Excited discharge effect
Erasure of remaining electrons
a-Se double layer
X-Ray
X-Ray
a-Se
a-Se
Read-out light
Erasure light
Fuji’s DOS vs Current FPD(TFT)
Image Lay-Out Comparison
No blurry
+
High optical resolution
 Finespun detection
Optical switching method
Fuji’s DOS
FUJIFILM’s original Xray detection sensor
 High DQE
Direct conversion method
Detection by Direct
conversion
No blurry
TFT(H사, S사)
Indirect conversion method
Signal is detected on
adjacent pixels.
Decline of sharpness
TFT (G사)
Target of new FPD
G사
H사, S사
Target of new FPD
-1 High image quality … Small pixel & high DQE
-2 Efficient workflow … Short interval between exp.
For Diagnostic
FUJIFILM FPD
Image Quality
DQE, Pixel pitch
Direct
FPD (TFT)
H사, S사
In-direct
FPD (TFT)
G사
Workflow
Interval time
Image display time
For Screening
Comparison With Market Competitor
H사
S사
G사
AMULET
FPD manufacturer
Original
Original
Anrad
Original
Direct/ In-direct
Direct
Direct
Direct
In-direct
a-Se
a-Se
a-Se
CsI
Direct Optical S
witching
TFT
TFT
TFT
50μm
70μm
85(70)μm
100μm
Excellent
Good
Good
No good
25~35 sec
30 sec
Mo / Rh
W / Mo
Material
Reading method
Resolution
DQE
Shot interval
X-ray Tube
15
sec
W / Mo
10
sec
Mo
Fujifilm AMULET Digital Mammography System
PACS
Fujifilm Mammo Viewer
DICOM
Image
Acquisition
DICOM PRIVATE
QA / QC Program Consistency
Best Mammo Image On Fujifilm Mammo Viewer !!!
AMULET Mammography Images
Ergonomic Design for Screening Position
■ Comfortable
Patient Usability
・Ergonomic Design in shape of arm-rests and grip handles
(Comfortable Positioning for Mammography Screening)
・Tactile Surface Fabrication of exposure table
・Disposable pads reducing discomfort (for Patient Positioning)
Specifications of AMULET
■Specifications of X-ray unit
High voltage power source :Inverter
Size:W920*D1175*H1930~2350 cm
Target:Mo, W
Nominal voltage:23~35kV
Filter:Mo, Rh
Focus size: Large:0.3cm, Small:0.1cm
SID:650mm
■Specifications of FPD unit
Method: Direct Conversion
Panel Material: a-Se
Pixel Size: 50x50μm/pix
Output gradation: 14bit
Pixel count: 3540*4740=16,779,600 pixels
Grid: 31 lines/cm, Aspect ratio 5:1
AEC Mode:Full, Semi, Manual
AWS (Acquisition Work Station)
■Fine operability with Vertical designed screen
■1, 2 or 4 Images Display Mode
■Auto Image Positioning function
■Exposure mode (pre-set) setting
■Tube voltage setting
■mAs value setting
■The combination of the target and filter
■Dose level setting
■Grid IN/OUT setting
■Focal spot size setting
■C-arm degree setting and display
■Breast thick.(mm) & Compression Force(N) display
■Exposure table type & Compression plate type display
Configuration and options
Standard
Options
Special compression paddles
Mag
Axillar
1.8time Mag stand
Spot
Handswitch
Mag Spot
Storage Rack
AMULET Main unit
Exposure unit (incl. Control box) and AWS with chest
Ctrl BOX
Footswitches (x2)
Radiation switch
Radiation shield
FUJI original mammographyQC
1Shot Phantom M Plus
Compression paddles (High/Low))
Pads (consumable option)
Axillar pad
Chest wall pad
2. 최상의 Mammo Image
Quality를 위한 가장 경제적인 제안
Fuji MAMMO CR
“FCR Profect CS”
PROFECT CS 는 …
아래 모든 조건의 병원에 최선의 선택입니다!!!
* 건강검진센터(유방촬영 포함), 유방암 관련 특성화를 계획하는 병원
* Mammo를 Film 및 일반 CR Image에서 최상의 Image로 변경하고자 하는 병원
(FUJIFILM Mammo 전용 Viewer 탑재)
* 기존 Mammo 촬영기와의 연동을 원하는 병원
* 정확한 Mammo 검진을 위해 최소의 투자, 최고의 Mammo Quality를 원하는 병원
* Mammo 외의 다른 부위 촬영도 Digital로 촬영을 요하는 병원
PROFECT CS의 특성
“FIRST,ONLY”
Mammography
FDA Approval
세계 CR 중 최초이며 유일한 FDA 승인
최상의 Mammo Image Quality 지원
50㎛ pitch, Dual-side reading
기존 Mammo 촬영 장비
그대로 이용 가능
DIAGNOSIS
: Exellent !!!
DSR(Dual-Side Reading)
Technology
PROFECT CS는 단 방향으로 Reading 을 하던 기존 CR의 모습을 벗어나 Dual-Side
Reading Technology를 개발했습니다. 이를 통해 최상의 Mammo Image는 물론,
20pixel/mm(50㎛ reading) 를 실현하였습니다.
Image 비교
(100㎛ vs. 50㎛ Reading)
1
mm
100 micrometer
1
mm
50 micrometer
PEM(Pattern Enhancement
Processing for Mammography) S/W
Original Image
PEM
Same Enhancement Level and Suppression of Noise Level
PEM SOFTWARE
PEM 비적용 시
PEM 적용 시
PEM 적용 시
(병변을 강하게 표현)
FCR PROFECT CS and
FUJIFILM Mammography System
PACS
Fujifilm Mammo Viewer
DICOM
Image
Acquisition
DICOM PRIVATE
QA / QC Program Consistency
Best Mammo Image On Fujifilm Dicom Private !!!
FUJIFILM MAMMO VIEWER
Mammography Workstation
* Mammography 영상을 위해 FUJIFILM은
전용 Workstation을 제공합니다.
- 일반 Dicom Processing이 아닌 FUJIFILM
전용의 Dicom Private Processing 사용
* 5-mega pixel LCD를 통해 Optimal Viewing
Conditions을 확인하실 수 있습니다.
- Mammo DR보다 우수한 Image 구현
* MFP and PEM Processing software를 통해
Mammo Image 최적화를 앞당겼습니다.
* Micro-Cacification의 명확한 확인이 가능합니다.
PROFECT CS: Comparison – vs.
FPD Mammo
FCR PROFECT CS 는 FPD(TFT) Mammo DR보다 우수한 영상을 구현합니다.
Item
Fuji Profect CS
G사 Mammo DR
H사 Mammo DR
Technology
CR
A-Si
A-Se
Pixel Size
50
100
70
Detector Size
18x24,24x30
18x24
24x29
Workstation
5-MegaPixelLCD
5-MegaPixelLCD
5-MegaPixelLCD
Viewing P/G 유,무
◎
◎
◎
PROFECT CS - Application
1. 2개의 촬영실 보유시에도
Exam Room #1
Exam Room #2
2. PROFECT CS 한 대로 모든
Digital imaging 처리가 가능
3. 양쪽 모두 동일한
Image Quality를 구현
4. 기존 Mammo 촬영기의 교체
없이도 Mammography 를
Digital로 처리
(Mammo DR의 경우 양쪽 모두
교체가 이뤄져야 함: 비용 )
최상의 Digital Mammography Image
PROFECT CS Reference Sites
설치 병원 명
설치 수량
설치 병원 명
설치 수량
을지대학교 둔산 병원
2
김해성모병원
1
한일병원
2
진해용원병원
1
한림대학교 춘천병원
1
동수원 병원
2
이화여자대학교 동대문병원
1
중앙대학교 흑석동병원
1
중앙대학교 흑석동병원
2
메디넷 종합검진
1
이화여자대학교 목동병원
1
인천사랑병원
1
부천 세종병원
1
영광종합병원
1
건양대학교병원
1
리더스 영상의학과
1
원자력 병원
1
오 병원
1
한솔 병원
1
좋은 문화병원
2
김포우리병원
1
대한병원
1
대전 온누리 클리닉
1
인천한림병원
1
부산위생병원
1
동양방사선과
1
한국방사선과
1
리더스 이 내과
1
여의도중앙검진센터
1
건강관리협회 부산지부
2
춘해 병원
1
하나로 영상의학과
1
메디스콥 병원
1
21세기진단방사선과
1
강릉 의료원
1
건강관리협회 서울지부
1
진주영채내과
1
순천제일병원
1
인천 힘찬 병원
1
인제대 일산 백 병원
1
합계
47
FUJI FILM is supporting the Pink Ribbon Campaign
Thank You