All about tap water systems
Download
Report
Transcript All about tap water systems
All About
Tap Water Systems
Everything you needed to know about Tap Water Systems
version 2010.1
Introduction
HOME
Products
Applications
Technology
Service
Contact
© Alfa Laval
Slide 3
www.alfalaval.com
Home
Products
Storage Vessels
Instantaneous
Semi-Instantaneous
© Alfa Laval
Anti-Legionella
Compact
Swimming Pool
Solar
Customized
Systems
Slide 4
www.alfalaval.com
All Products
Instantaneous
Semi- Instantaneous
with charging pump(s) for
connection to a storage tank
no connection to a storage tank
AquaFlow
2 Port
25bar / 130°C
© Alfa Laval
AquaStore
3 & 4 Port
2 Port
3 & 4 Port
10bar / 110°C
25bar / 130°C
10bar / 110°C
Why 2 , 3 or 4 Port valve
Slide 5?
www.alfalaval.com
details lime scaling:
2 – 3 – 4 Port Valve
2-Port
Principle
Comments
Regulates the primary flow
through the HE which gives a
variable flow rate
Suitable for District Heating
2 Port valve connected to a controller
ensures right flowrate, thus constant
water temperature on secondary side
up to 25 bar & 130 °C
3-Port
Regulates the primary
temperature in the HE and
gives a constant flow rate
up to 10 bar & 110°C
4 Port
Regulates the primary
temperature in the HE and
gives a constant flow rate
Connected to a local boiler or
Primary tank on site
No risk of thermal shock
Limited lime scaling
Energy efficient as only required
energy is used
Necessary if HE is located away
from local boiler or Primary tank
to avoid « cold water train »
No need of mixing bottle
up to 6 bar & 110°C
© Alfa Laval
Slide 6
www.alfalaval.com
Lime Scaling
Low Demand
Primary circuit
75°C
55°C
Peak Period
75°C
85°C
55°C
85°C
Surface plate
temperature +/- 55°C
Primary circuit
Calcium bicarbonate
sticks to the plates and
becomes a solid wall in
the heat exchanger
Calcium bicarbonate
circulates without
sticking to the plates
Surface plate
temperature +/- 55°C
Calcium bicarbonate
balls
appear
35°C
40°C
35°C
35°C
10°C
35°C
Secondary circuit
Secondary circuit
(circulating water + city water)
(city water only)
When secondary water circuit is higher than 45°C
&
Surface plate temperature is 10°C higher than secondary water circuit
Thermal Shock
www.alfalaval.com
Lime
Scaling
AquaFlow / Store: 2 Port valve
AquaFlow
AquaStore
Self Actuated
Electronic version Micro 2000
© Alfa Laval
Insulations
Heat exchangers
Why Self Actuated
Slide 8or Electronic ?
Electronic version Samson 5433
www.alfalaval.com
Heat exchangers 2 Port version
Copper Brazed or AlfaNova
CB & AN 27, 52 and 76
up to 350 kW for Self Actuated version
up to 500 kW for Electronic versions
25 bar
(for type 27 & 52)
16 bar
(for type 76)
130 °C
© Alfa Laval
Plates & Gaskets
M3 and M6/M6M AISI 316 with clip-on EPDM gaskets
up to 250 kW for Self Actuated version
up to 350 kW for Electronic versions
10 bar
110 °C
Slide 9
www.alfalaval.com
Insulation AquaFlow / Store 2 Port
Copper Brazed or AlfaNova
Plates & Gaskets
(included as standard)
(optional)
Reduces heat losses
Pay back period: less than one year
© Alfa Laval
Slide 10
www.alfalaval.com
Why Self Actuated or Electronic?
Self Actuated
If standard use is requested: no need for electronic regulation
Low cost version
Electronic
If higher performance is requested: electronic
regulation gives a lot of different functions
(see details Micro 2000 and Samson 5453)
© Alfa Laval
Slide 11
www.alfalaval.com
/
AquaFlow / Store: 3 & 4 Port valve
AquaFlow
AquaStore
Copper Brazed
AlfaNova
Plates & Gaskets
up to 350Kw
up to 350kW
up to 1220 kW
Benefits
Benefits
Benefits
©
www.alfalaval.com
Working Principle :
AquaFlow
AquaStore
Controlbox :
Micro 2000
Samson 5433
Home
AquaFlow / -Store 3 & 4 Port
Benefits AquaFlow / Store: Copper Brazed
Technical
Cost
Other
• Thermal efficiency
• Low heat losses
• Any heating source
• Limited lime scaling
• Easy and quick
installation
• Compact design
• Eliminates thermal
shocks
• Easy maintenance
• Low cost solution
© Alfa Laval
Slide 13
• Short delivery time:
5 to 7 days
• For AquaStore: double
headed charging pump
as option
www.alfalaval.com
Thermal efficiency
© Alfa Laval
Plates and frame without gaskets
Extremely efficient heat transfer due to the thin plates of the Copper Brazed
Increased turbulence due to high speed in the channels
Ideal solution to combine with a condensing boiler, thanks to the possibility to have a
low return temperature
Slide 14
www.alfalaval.com
details Lime scaling:
Limited Lime Scaling*
Due to high water turbulence in the channels
Scaling Function* indicates a decrease of the heat
exchanger efficiency due to scaling
Cleaning can be planned in time; no risk of blocked
channels in heat exchanger
Economic use of heat exchanger
*
© Alfa Laval
For systems fitted with an extra sensor on the primary circuit feedback
Slide 15
www.alfalaval.com
details 3 or 4 Port Valve:
Eliminates thermal shock
by using a 3 Port mixing valve
or
a 4 Port mixing valve
The mixing valve opens following the
demand for Domestic Hot Water
© Alfa Laval
Slide 16
www.alfalaval.com
Lime Scaling
Low Demand
Primary circuit
75°C
55°C
Peak Period
75°C
85°C
55°C
85°C
Surface plate
temperature +/- 55°C
Primary circuit
Calcium bicarbonate
sticks to the plates and
becomes a solid wall in
the heat exchanger
Calcium bicarbonate
circulates without
sticking to the plates
Surface plate
temperature +/- 55°C
Calcium bicarbonate
balls
appear
35°C
40°C
35°C
35°C
10°C
35°C
Secondary circuit
Secondary circuit
(circulating water + city water)
(city water only)
When secondary water circuit is higher than 45°C
&
Surface plate temperature is 10°C higher than secondary water circuit
Thermal Shock
www.alfalaval.com
Lime
Scaling
3 or 4 Port Valve
3-Port
4 Port
Principle
Comments
Regulates the primary
temperature in the HE and
gives a constant flow rate
up to 10 bar & 110°C
Regulates the primary
temperature in the HE and
gives a constant flow rate
Necessary if HE is located away from local
boiler or Primary tank to avoid « heattrain »
No need of mixing bottle
Connected to local boiler or
Primary tank on site
No risk of thermal shock
Limited lime scaling
Energy efficient as only required energy is
used
up to 6 bar & 110°C
© Alfa Laval
Slide 18
www.alfalaval.com
Low Heat Losses
due to Heat Exchangers insulation
© Alfa Laval
Slide 19
www.alfalaval.com
Copper Brazed AlfaNova
Plates & Gaskets
Easy and quick installation
Plug and Play
Fully assembled
Electrical wired
Pressure tested
Calibrated to customers need
Complies with European Directives 73/23 and
PED 97/23 CE – Art. 3.3
© Alfa Laval
Slide 20
www.alfalaval.com
Copper Brazed AlfaNova
Easy maintenance
CIP = Cleaning In Place
Alfa-CIP is a convenient solution that carefully
removes the deposit on all heat transfer surfaces
in the heat exchanger.
A chemical agent is circulated in the HE to
remove the scaling deposit.
Benefits :
© Alfa Laval
Removes scaling without opening
Increases lifetime of heat exchanger
Minimises downtime
Cost effective
Slide 21
www.alfalaval.com
Copper Brazed AlfaNova
Plates & Gaskets
For any heating source
District Heating
Local Heating
Any source of energie can be combined with our Tap Water Systems
© Alfa Laval
Slide 22
www.alfalaval.com
Copper Brazed AlfaNova
Compact Design
© Alfa Laval
Model
AquaFlow
L/W/H
AquaStore
L/W/H
CB or AN 27
535/485/965mm
535/720/956mm
CB or AN 52
500/500/1230mm
500/720/1230mm
Slide 23
www.alfalaval.com
Copper Brazed AlfaNova
Plates & Gaskets
Secondary Pump (s)
•
•
Single or Double Headed
Cast iron, Bronze or Stainless Steel
Benefits Double Headed:
Spare pump in case of default
Booster function, 130% capacity in case of
peak demand in short time
© Alfa Laval
Slide 24
www.alfalaval.com
Home
AquaFlow / - Store 3 & 4 Port
Benefits AquaFlow / Store: AlfaNova
Technical
• Very high heat
transfer
• Corrosion resistance
• Extremely low lime
scaling
© Alfa Laval
Cost
Other
• Cost efficient
• Any heating source
• Low heat losses
• Compact design
• Easy and quick
installation
• Short delivery time:
5 to 7 days
• Easy maintenance
• For AquaStore: double
headed charging pump
as option
Slide 25
www.alfalaval.com
Very High Heat Transfer
Due to thin plates and high turbulence in heat exchanger
2 sizes: AN 57
(50 to 210kW)
AN 52
(260 to 350kW)
Plates and frames without gaskets
100% Stainless Steel ; unique to Alfa Laval
Alfa Nova has the muscle to replace large and heavy heat exchangers
Ideal solution to combine with a condensing boiler, thanks to the
possibility to have a low return temperature
© Alfa Laval
Slide 26
www.alfalaval.com
Corrosion resistant
Improved corrosion resistance and mechanical stress (100% SS)
Extremely hygienic: no release of metal ions that contaminate or
colour the water
Environmental friendly: fully recyclable
Suitable for all DHW pipeworks (100% copper free): no oxidization
Can be used in acidic water where copper is not corrosion resistant
© Alfa Laval
Slide 27
www.alfalaval.com
Extraordinairy low lime scaling
Cut out of the upper part of an AlfaNova
(part the most exposed on high temperature and scaling)
Result of scaling of an AquaFlow with Alfa Nova heat
exchanger after 1,5 year of use in a region with medium
water hardness (35°TH = 20dH):
Primary side is as brand new
Secondary side has a very slight deposit which affects
only 3% of the nominal thermal exchange, pressure drops
and capacity
90°C
Primary side
© Alfa Laval
55°C
Secondary side
Slide 28
www.alfalaval.com
Cost efficient AlfaNova
AquaFlow with AlfaNova
AquaFlow with Plates & Gaskets
€
© Alfa Laval
Slide 29
www.alfalaval.com
Low Heat Losses
thanks to Heat Exchangers insulation
© Alfa Laval
Slide 30
www.alfalaval.com
Home
AquaFlow / - Store 3 & 4 Port
Benefits AquaFlow / Store: Plates & Gaskets
Technical
• High and flexible
capacity
Cost
• Low heat losses
• Any heating source
• Easy and quick
installation
• Compact design
• Cleaning possibility
• Cost effective and very
long lifetime ( more
than 25 years)
© Alfa Laval
Other
• Short delivery time:
5 to 7 days
• For AquaStore: double
headed charging pump
as option
www.alfalaval.com
High and flexible Capacity
Up to 1220 kW
2 sizes:
- M3 high theta
- M6 high and low theta
Possibility to increase capacity by adding number of plates
© Alfa Laval
Slide 32
www.alfalaval.com
Cleaning Possibility
Heat exchanger can always be disassembled and
assembled after cleaning
Clip on Gaskets for quick maintenance
© Alfa Laval
Slide 33
www.alfalaval.com
Low heat losses
Energy saving Insulation for Plates & Gaskets HE is optional
Pay back period less than one year
Slide 34
www.alfalaval.com
Compact Design
© Alfa Laval
Model
AquaFlow
L/W/H (in mm)
AquaStore
L/W/H (in mm)
M3 Plates
100
300
500
600/400/995
815/465/995
none
600/530/995
815/600/995
815/600/995
M6M Plates
200
400
600
800
900
1000/500/1400
1000/500/1400
1150/500/1400
none
none
1000/600/1400
1000/600/1400
1150/600/1400
1150/600/1400
1150/600/1400
Slide 35
www.alfalaval.com
details:
Working Principle AquaFlow
© Alfa Laval
Slide 36
(3 port valve)
www.alfalaval.com
Customers
source of energy:
• Local boiler
• District network
• Primary tank
• Solar system
•…
= Circulation Pump to maintain a minimum flow rate through the entire network
= Primary Pump maintains a constant flow rate through the heat exchanger
= S1 checks the temperature and adjusts the control valve to maintain hot water
= S2 indicates if circulation water has reached 70°C minimum for thermal treatment (optional)
= S3 indicates a decrease of the heat exchanger efficiency due to scaling (optional)
© Alfa Laval
Slide 37
www.alfalaval.com
details:
Working Principle AquaStore
© Alfa Laval
Slide 38
(3 port valve)
www.alfalaval.com
Customers
source of energy:
• Local boiler
• District network
• Primary tank
• Solar system
• etc.
Circulation Pump
flow rate must be
60% lower to
Charging Pump
flow rate
= Circulation Pump to maintain a minimum flow rate through the entire network
= Charging Pump on secondary side is used to store hot water in the storage vessel.
The stored hot water is only used for peak period when the Domestic Hot Water (DHW) demand is
higher than the energy supply. If storage vessel is emptied before the end of the peak period, DHW
will be provided at a nominal flow rate corresponding to the energy input on site.
= S1 checks the temperature and adjusts the control valve to maintain hot water
= S2 indicates if circulation water has reached 70°C minimum for thermal treatment (optional)
© Alfa Laval
= S3 indicates a decrease of the heat exchanger
Slide 39 efficiency due to scaling (optional)www.alfalaval.com
AquaFlow / -Store 2 port
AquaFlow / -Store 3 & 4 port
AquaCompact
AquaProtect
Control Box: Micro2000
(Alfa Laval’s exclusivity)
Temperature Alarm
Eco
Booster
Thermal treatment
Scaling
Autotest
Building Managment Systems
LCD display
Temperature Recorder & download
History
On/Off remote
PID type controller
Options for Control Box Micro 2000
© Alfa Laval
Slide 40
www.alfalaval.com
Temperature Alarm
High Alarm:
the Tap Water temperature at the outlet of the heat exchanger
exceeds 10% the set point temperature; the power supply to the
primary circuit pump is cut
when the temperature has decreased below the high temperature
threshold value (1 °C), the system can be re-activated either
manually or automatically
Low Alarm:
the Tap Water temperature at the outlet of the heat exchanger
undershoots 12°C the set point temperature
early warning for possible operating disturbances
© Alfa Laval
Slide 41
www.alfalaval.com
Eco Function
If temperature does not decrease for a given period and the
control valve is closed, the Primary pump will stop.
Primary pump re-starts when temperature falls below set point
and the control valve opens
The charging and recycling pumps (if existing) are still running
Disengageable function
© Alfa Laval
Slide 42
www.alfalaval.com
Booster Function *
If tap water temperature decreases rapidly both primary pumps are
activated
Provides more primary flow rate thus more output to compensate
the sudden temperature drop on the secondary side
The 2nd Primary pump head is switched off once the set point value
is reached again
Disengageable function
* available when twin-head primary pumps are fitted
© Alfa Laval
www.alfalaval.com
Thermal Treatment Function
Temperature is raised to 70°C to eridicate legionella
bacterie in the complete network
Treatment at a preset day and time (in general once a
week at night when little demand)
Adjustable duration (in general 2 hours)
Disengageable function
© Alfa Laval
Slide 44
www.alfalaval.com
details Lime scaling:
Scaling Function *
Indicates a decrease of the heat exchanger efficiency
due to scaling (details about lime scaling see right
corner button)
Cleaning can be planned in time > no risk of blocked
channels in heat exchanger
extra sensor
Economic use of heat exchanger
* for systems fitted with an extra sensor on the primary circuit feedback
© Alfa Laval
Slide 45
www.alfalaval.com
Lime Scaling
Low Demand
Primary circuit
75°C
55°C
Peak Period
75°C
85°C
55°C
85°C
Surface plate
temperature +/- 55°C
Primary circuit
Calcium bicarbonate
sticks to the plates and
becomes a solid wall in
the heat exchanger
Calcium bicarbonate
circulates without
sticking to the plates
Surface plate
temperature +/- 55°C
Calcium bicarbonate
balls
appear
35°C
40°C
35°C
35°C
10°C
35°C
Secondary circuit
Secondary circuit
(circulating water + city water)
(city water only)
When secondary water circuit is higher than 45°C
&
Surface plate temperature is 10°C higher than secondary water circuit
Thermal Shock
www.alfalaval.com
Lime
Scaling
Autotest Function
Checks that the core system components are operational
All systems are pre-tested electronically prior to shipping
can be used to test the equipment upon completed
maintenance work
© Alfa Laval
Slide 47
www.alfalaval.com
BMS: Building Management System
To relay to a BMS
Remote enable/disable function
Possibility to use the eco function to enable/disable the boilers
6 error messages can be displayed:
1.
2.
3.
4.
5.
6.
© Alfa Laval
High Temperature alarm
Low Temperature alarm
Thermal treatment fault
Sensor fault
Pump fault
Fouled Heat Exchanger
Slide 48
www.alfalaval.com
LCD display
Shows set point or measured temperature
Displays parameters and alarms in clear language
Multiple language options:
1.
2.
3.
4.
5.
6.
7.
8.
© Alfa Laval
English
French
German
Dutch
Spanish
Italian
Danish
Other on request
Slide 49
www.alfalaval.com
Control Box options
8-Relay Card which allows to report 2 Primary and 2
Secondary pumps, sensors, low temperature alarm,
eco and thermal treatment functions
230V 3 Points Signal Converter Card which allows
to connect a 230V 3 Points Actuator to the Control
Box
Download Software and Cable allows to link the
Control Box to a computer for charts on Excel to
track the temperature over a defined period of time
Control Box can be equipped with 2 Additional
Sensors (for thermal treatment and anti-scaling)
© Alfa Laval
Slide 50
www.alfalaval.com
AquaFlow / -Store 2 port
AquaFlow / -Store 3 & 4 port
AquaCompact
Control Box:Samson 5433
Inputs:
7 inputs for temperature sensors
Input alternatively for storage tank thermostat
1 input for room panel/potentiometer
1 input for demand/outdoor temperature 0 to 10 V
Outputs:
Three-step signal/ on/off signal
Load 20 to 250 V AC, 0.5 A (triac outputs with varistor
suppression)
Three-step/ on/off signal
Load 230 V AC, 2 A (relay outputs with varistor suppression)
3 pump outputs:
Load max. 230 V AC, 2 A (relay outputs with varistor
suppression)
1 output for demand/outdoor temperature 0 to 10 V
Operating voltage:
230 V AC (+10 %, –15 %), 48 to 62 Hz, max. 3 VA
© Alfa Laval
Slide 51
www.alfalaval.com
All Products
AquaCompact
Standard version
2-Port Self Actuated
2-Port Electronic
3-Port Electronic
(no Primary control)
© Alfa Laval
Why 2 or 3 Port valve?
Why Self Actuated or Electronic?
Slide 52
www.alfalaval.com
2 – 3 Port Valve for AquaCompact
2-Port
Principle
Comment
Regulates the primary flow
through the HE which gives a
variable flow rate
• Suitable for District Heating
up to 16 bar & 110 °C
3-Port
Regulates the primary
temperature in the HE and
gives a constant flow rate
up to 10 bar & 110°C
© Alfa Laval
Slide 53
• 2 Port valve connected to a controller
ensures the right flowrate, thus constant
water temperature on secondary side
• Connected to a local boiler or Primary tank
• No risk of thermal shock
• Limited lime scaling
• Energy efficient as only required energy is
used
www.alfalaval.com
Why Self Actuated or Electronic?
Self Actuated
if basic use is requested: no need for
electronic regulation
Low cost version
© Alfa Laval
Electronic
if higher performance is requested: electronic
regulation gives a lot of different functions
(see details Micro 2000 controlbox)
Slide 54
www.alfalaval.com
2-Port Self Actuated
Pre-sized charging kit:
10
3
2
8
1
6
5
4
9
7
1.
Heat exchanger
2.
Insulation
3.
2-Port Self Actuated valve
4.
Charging Pump
5.
Balancing Valve
6.
10 bar Pressure Relief Valve
7.
Isolating Valves & connection pipework
8.
Additional CIP ¾" connections
9.
Flexible Pipe
10. Tank
Slide 55
www.alfalaval.com
Heat Exchanger AquaCompact
Copper Brazed or AlfaNova
Plates & Gaskets
up to 190 kW
M3 clip-on
16 bar
110 °C
up to 240Kw
CB & AN 27 et 52
16 bar
110 °C
© Alfa Laval
Slide 56
www.alfalaval.com
Insulation AquaCompact
Copper Brazed or AlfaNova
Plates & Gaskets
(included as standard)
(as an option)
Low heat losses
Pay back period less than one year
© Alfa Laval
Slide 57
www.alfalaval.com
Isolating valves AquaCompact
Isolating valves to isolate the different components
Easy maintenance
Water savings
© Alfa Laval
Slide 58
www.alfalaval.com
Tanks for AquaCompact
Stainless Steel 316Ti
Enamel
Enamel
10 bar
10 bar
7 bar
300 to 1500L
© Alfa Laval
300 to 1500L
Slide 59
300 to 1500L
www.alfalaval.com
3 - Port Electronic
Pre-sized charging kit:
10
3
Heat exchanger
2.
Insulation
3.
Electronic Controlbox:
4.
Charging Pump
5.
Balancing Valve
6.
10 bar Pressure Relief Valve
7.
Isolating Valves & connection pipework
8.
additional CIP ¾" connections
9.
Flexible(s)
2
8
6
1.
1
5
4
9
7
Micro 2000
Samson 5433
10. Tank
Slide 60
www.alfalaval.com
Heat Exchanger AquaCompact
Copper Brazed or AlfaNova
Plates & Gaskets
up to 190 kW
M3 clip-on
16 bar
110 °C
up to 240Kw
CB & AN 27 et 52
16 bar
110 °C
© Alfa Laval
Slide 61
www.alfalaval.com
Insulation AquaCompact
Copper Brazed or AlfaNova
Plates & Gaskets
(included as standard)
(as an option)
Low heat losses
Pay back period less than one year
© Alfa Laval
Slide 62
www.alfalaval.com
Isolating valves AquaCompact
Isolating valves to isolate the different components
Easy maintenance
Water savings
© Alfa Laval
Slide 63
www.alfalaval.com
Tanks for AquaCompact
Stainless Steel 316Ti
Enamel
Enamel
10 bar
10 bar
7 bar
300 to 1500L
© Alfa Laval
300 to 1500L
Slide 64
300 to 1500L
www.alfalaval.com
All Products
Solar
SolarFlow
Copper Brazed or AlfaNova
10bar / 110°C
SolarTank
Plates & Gaskets
10bar / 110°C
Benefits SolarFlow
Working Principle SolarFlow
Primary Storage Tank
10bar / 100°C
www.alfalaval.com
Benefits SolarFlow
Energy savings up to 50%
All the energy accumulated in the primary tank is
used, whatever the temperature is.
Minimizes legionella growth by using a primary
instead of a secondary storage tank.
© Alfa Laval
Slide 66
www.alfalaval.com
Working Principle SolarFlow
Slide 67
more details:
www.alfalaval.com
The S4 sensor checks the temperature of the water entering into SolarFlow. This temperature
is compared to the temperature of the S5 sensor.
Than 2 possibilities occur:
1) if S5 > S4 SolarFlow is engaged: heat will be transferred in the Heat Exchanger.
The S sensor checks the secondary outlet temperature and adjusts the control valve accordingly.
2) if S5 < S4 SolarFlow is on standby: the control valve is closed, the Primary Pump is switched off.
Water flows through the Heat Exchanger without heat transfert and the DHW has to be heated up by
another source of energy.
SolarFlow has always to be combined with a conventional Tap Water System. Ask your local Alfa Laval sales office for a
detailed product brochure.
© Alfa Laval
Slide 68
www.alfalaval.com
SolarTank
• Primary Storage Tank made of carbon steel
• Volume: 300 – 3000 L
• Insulation:
100mmm rockwool cladded with aluminium plate
or
100mm glasswool with PVC jacket
• Maximum 10 bar / 100°C
Benefits:
Reduces boiler usage
Energy efficient through the storage of large quantities of heated
primary water
Can be combined with a SolarFlow to pre-heat the domestic tap
water
© Alfa Laval
Slide 69
www.alfalaval.com
All Products
Storage Vessels
Primary Storage
Secondary Storage
SolarTank
AquaTank Stainless Steel
AquaTank Stainless Steel with Heating Coil
AquaTank Enamel 10bar
AquaTank Enamel 10bar with Heating Coil
AquaTank Enamel 7bar
AquaTank Enamel 7bar with immersion heater
© Alfa Laval
Slide 70
www.alfalaval.com
SolarTank
• Primary Storage Tank made of carbon steel
• Volume: 300 – 3000 L
• Insulation:
100mmm rockwool cladded with aluminium plate
or
100mm glasswool with PVC jacket
• Maximum 10 bar / 100°C
Benefits:
Reduces boiler usage
Energy efficient through the storage of large quantities of heated
primary water
Can be combined with a SolarFlow to pre-heat the domestic tap
water
© Alfa Laval
Slide 71
www.alfalaval.com
AquaTank Stainless Steel (316 Ti)
Volume
150 – 4000L
Inspection opening
120 or 400mm
Insulation*
70 or 90mm
Maximum
10 bar / 95°C
* Insulation: 70 or 90mm polyurethane foam covered with a PS hard plastic or an aluminium plate
(according to volumes)
Benefits:
All tap water side components are made of stainless steel AISI 316Ti
High effectiveness for maximum hot water due to internal tube
arrangement
Environment-friendly insulation which garantuees the lowest heat
losses
Insulation very easy to remove and to refit
All volumes are equipped with connections for electrical immersion
heaters
Tanks up to 1000L are stocked in 3 different places in Europe for
quick delivery
© Alfa Laval
Slide 72
www.alfalaval.com
AquaTank Stainless Steel with HC
125 – 1000L
Volume
Inspection opening
Insulation*
2 " or 120 mm
70 or 90mm
Maximum pressure
Maximum temperature
10 bar for tank / 25 bar for coil
95°C for tank / 200°C for coil
Insulation: 70 or 90mm polyurethane foam covered with PS hard plastic (according to
volume)
Benefits:
Unique shape of HC reaches down to the bottom and
heats up all the water of the tank
All tap water side components & the heating coil are
made of stainless steel AISI 316Ti
Environment-friendly insulation which garantuees the
lowest heat losses
Insulation very easy to remove and to refit
© Alfa Laval
Slide 73
www.alfalaval.com
AquaTank Enamel 10 bar
200 – 1000L
Volume
Inspection opening
120 mm
Insulation*
50 or 100mm
Maximum
10 bar / 95°C
polyurethane foam covered with PVC jacket or metal plate (according to volume)
Benefits:
All tap water components have the hygienic coating of
enamel (glass lined)
Allows storage with chlorinated water
High effectiveness for maximum hot water due to internal
tube arrangement
Environment-friendly insulation which garantuees the lowest
heat losses
Low cost tanks
© Alfa Laval
Slide 74
www.alfalaval.com
AquaTank Enamel 10 bar with Heating Coil
200 – 1000L
Volume
Inspection opening
Insulation*
180 or 240 mm
50 or 100mm
Maximum pressure
Maximum temperature
10 bar
95°C for tank / 110°C for coil
polyurethane foam covered with PVC jacket or metal plate (according to volume)
Benefits:
Heating coil reduces the power demand
All tap water components have the hygienic coating of enamel
(glass lined)
Allows storage with chlorinated water
High effectiveness for maximum hot water due to internal tube
arrangement
Environment-friendly insulation which garantuees the lowest
heat losses
© Alfa Laval
Slide 75
www.alfalaval.com
AquaTank Enamel 7 bar
300 – 3000L
Volume
Inspection opening
110 / 260 or 400 mm
Insulation*
50 or 100mm
maximum
7 bar / 90°C
* glass wool covered with PVC-jacket or
rock wool cladded with aluminium metal plate
Benefits:
All tap water components have the hygienic coating of
enamel (glass lined)
Allows storage with chlorinated water
All volumes are equipped with connections for electrical
immersion heaters
Insulation very easy to remove and to refit
© Alfa Laval
Slide 76
www.alfalaval.com
AquaTank Enamel 7 bar with
Immersion heater(s)
Volume
Inspection opening
Incoloy
Soapstone
300 – 1500L
1000 – 3000L
110mm
400mm
Insulation*
50 or 100mm
maximum
7 bar / 90°C
* glass wool covered with PVC-jacket or
rock wool cladded with aluminium metal plate
« Incoloy »
or
« Soapstone »
© Alfa Laval
Benefits:
2 types of immersion heaters available: incoloy (direct
contact with water) or soapstone (with glove for hard water)
All tap water components have the hygienic coating of
enamel (glass lined)
Allows storage with chlorinated water
High effectiveness for maximum hot water due to internal
tube arrangement
Insulation very easy to remove and to refit
Slide 77
www.alfalaval.com
All Products
Anti - Legionella
AquaProtect T1
AquaProtect T2
(3 port valve on Primary / instantaneous or semi-instantaneous)
(2 port valve on Primary / Temperature safety function with diverting valve /
reaction tank / semi-instantaneous only)
10bar / 110°C
© About Legionella
16 to 25 bar / 110 to 130°C
Working principle AQP
T278
Slide
Benefits
www.alfalaval.com
About Legionella
48 different Legionella species are known. They occur in low numbers in natural
environments such as rivers, lakes and reservoirs where they can survive
temperatures as low as 60C and as high as 500 C. Generally speaking they grow
best at temperatures between 20 to 450 C and are at their most virulent at 370 C.
The problem is that the bacteria can migrate into and thrive in man-made water
systems. Enclosed, warm storage vessels, pipe-work with lots of blind spots and
under-utilised water systems containing stagnant water provide an ideal
environment in which bacteria can flourish.
Legionella in Domestic Hot Water (DHW) Systems
Domestic as used here applies to all non-process water used for showers, hot
water, eating etc. Legionnaires’ disease may be contracted from any of these
sources by inhaling aerosol droplets. Hot and cold water systems in buildings are
the source of most reported cases of Legionnaires’ disease.
Health & Safety obligations
Any person, either individually or as an officer of a company or group, that owns or
operates water systems on any premises, is legally responsible for the control of
Legionella and its attendant risks.
Alfa Laval designed AQUAPROTECT to avoid any risk of Legionella in your
premises.
www.alfalaval.com
Working principle AquaProtect T2
details:
T2
www.alfalaval.com
AquaProtect T2 with combined Reaction-Storage Tank
70°C
70°C
70°C
80°C
Boiler inlet
HE to disinfect water at 70°C
4050°C
70°C
20 - 65°C
70°C for
x minutes
70°C
70°C
70°C
1540°C
60°C
HE with 2 functions:
1) to cool water down from 70°C
to 60°C to enter in the network
2) to pre-heat incoming and
circulation water
To network
55°C
10°C
= temperature safety function & diverting valve which ensures that only disinfected water enters the reaction tank.
Water that has not attained the right temperature (70°C) is diverted to the beginning of the process.
Ask you local Alfa Laval sales office for a detailed
product brochure
Slide 81
© Alfa Laval
www.alfalaval.com
AquaProtect provides
100% Security
Safe eradication of all Legionella from entire hot water systems
(incoming and circulating water)
Temperature safety function
Over-tapping protection
Network disinfection on demand or at pre-determined intervals
Energy saving
Energy is recovered in the heat exchanger so that thermal disinfection
consumes no extra energy
Can also be connected to alternative energy sources such as solar,
heat pump etc
Comfort
Compact system design
Requires low maintenance
Standardized systems for all water hardnesses
Easy to use and monitor control system
Experience and expertise
Maximum quality for maximum security
© Alfa Laval
Slide 82
www.alfalaval.com
AquaProtect T1
Plates & Gaskets heat exchanger
3 Port valve on Primary side
Instantaneous or Semi-Instantaneous
174 to 756 kW
Electronic Control box Micro2000
Insulations for heat exchangers as option
Ask your local Alfa Laval sales office for a detailed
product brochure
© Alfa Laval
www.alfalaval.com
Insulation AquaProtect
© Alfa Laval
Low heat losses
Pay back period less
than one year
Slide 84
www.alfalaval.com
AquaProtect T2
Plates & Gaskets or Brazed heat exchanger
Always Semi-Instantaneous
Diverting valve with temperature safety function
87 to 763 kW
Trovis controller 5479
Standard Reaction tank or combined Reaction-Storage Tank
Ask your local Alfa Laval sales office for a detailed
product brochure
© Alfa Laval
www.alfalaval.com
Trovis Controller AquaProtect T2
2 versions:
BOPLA type:
Plastic controlbox inclusive net disinfection internal adjustable
(daily, weekly, monthly, yearly) or external on demand
Prepared to be connected to flow switch (protection against
exessive load/tapping)
RITTAL type:
Carbon Steel controlbox, same functions as Bopla
+ Additional volt free contact for malfunction (temperature fault
and sensor break)
+ Interface RS485 including bus cable RJ12
Controller Trovis 5479 L – FS
© Alfa Laval
Slide 86
www.alfalaval.com
All Products
AquaPool
To reheat and maintain temperature of swimming pool
water of all dimensions
Can be connected to any Primary heating source
The electronic thermostat sensor controls the swimming
pool inlet temperature
The primary pump is switched on and off according to
the controller demand
On/off control
© Alfa Laval
Working Principle
Main components
Slide 87
www.alfalaval.com
Main Components AquaPool
2
5
6
3
4
7
1 Heat exchanger Plates & Gaskets:
- 316Ti
- Titanium (for sea or thermal water)
2 Electrical Panel IP 55
3 Primary Pump, single headed, 230V
1
4 Non-return valve on Primary pump outlet
5 Isolating valves on Primary inlet and outlet
6 2 PVC connectors for swimming pool circuit
6
7 PVC pocket for electronic controller temperature sensor
© Alfa Laval
Slide 88
www.alfalaval.com
details:
Working Principle AquaPool
© Alfa Laval
Slide 89
www.alfalaval.com
Customers
source of energy:
• Local boiler
• District network
• Primary tank
• Solar system
•…
3 step Working Principle:
1. Define the volume of the pool
2. Temperature rise needed to get the right swimming pool temperature
3. Time necessary to heat up the pool
= Primary Pump
= flow switch (on request)
= PTC 1000 temperature sensor
= by pass on site
(only +/- 20% of the water circuit
needs to flow through the AquaPool
heat exchanger)
= water treatment on site
www.alfalaval.com
All Products
Customized Systems
If the standard Tap Water Systems do not meet your exact
requirements, the Alfa Laval Tap Water Centre has a
“SPECIAL SYSTEMS DEPARTMENT”
which can work closely with customers to ensure the
systems supplied are tailored to your needs.
Please contact your local Alfa Laval sales office.
© Alfa Laval
Slide 91
www.alfalaval.com
Home
APPLICATIONS
The below mentioned ‘slide show’ gives you
an idea where our Tap Water Systems can
be installed.
Tap water is very much a
part of modern living.
© Alfa Laval
see slide show
Customer heating sources
Slide 92
www.alfalaval.com
AquaFlow
AquaStore
AquaCompact
AquaTank
AquaProtect
Apartment blocks
© Alfa Laval
Slide 93
www.alfalaval.com
AquaFlow
AquaStore
AquaCompact
AquaTank
AquaProtect
Hospitals
© Alfa Laval
Slide 94
www.alfalaval.com
AquaFlow
AquaStore
AquaCompact
AquaTank
AquaProtect
Gyms, sport clubs, fitness/wellness centers
© Alfa Laval
Slide 95
www.alfalaval.com
AquaFlow
AquaStore
AquaCompact
AquaTank
AquaProtect
Hotels
© Alfa Laval
Slide 96
www.alfalaval.com
AquaFlow
AquaStore
AquaCompact
AquaTank
AquaProtect
Campsites
© Alfa Laval
Slide 97
www.alfalaval.com
AquaFlow
AquaStore
AquaCompact
AquaTank
AquaProtect
Nursing Homes
© Alfa Laval
Slide 98
www.alfalaval.com
AquaFlow
AquaStore
AquaCompact
AquaTank
AquaProtect
Prisons
© Alfa Laval
Slide 99
www.alfalaval.com
AquaFlow
AquaStore
AquaCompact
AquaTank
AquaProtect
Universities & Schools
© Alfa Laval
Slide 100
www.alfalaval.com
AquaFlow
AquaStore
AquaCompact
AquaTank
AquaProtect
Industries
© Alfa Laval
Slide 101
www.alfalaval.com
Everywhere Domestic Hot
Water is needed…..
FAST and in LARGE
volumes
© Alfa Laval
Slide 102
www.alfalaval.com
Home
Applications
AquaPool
Swimming Pools
- end slide show © Alfa Laval
Slide 103
www.alfalaval.com
Customers Heating Sources
District Heating
Local Heating
Any source of energie can be combined with our Tap Water Systems
© Alfa Laval
Slide 104
www.alfalaval.com
Home
Technology of Tap Water Systems
Key requirements
District or Local Heating
Instantaneous or Semi-instantaneous
How to dimension
© Alfa Laval
Slide 105
www.alfalaval.com
Key requirements
Key requirements for supplying domestic hot water:
•
•
•
•
•
•
Healthy
no build-up bacteria cultures
Cost-efficient
low up-front investment, operating and maintance costs
Energy-efficient
low energy consumption
Space-efficient
using minimal floor and room space
Installation-efficient
simple and quick to install, test and start up
Service-efficient
easy to clean and maintain; long maintenance intervals with
short service shut-downs
•
Comfortable
no waiting for hot water and appropriate temperature levels,
no risk of scaling at the tap
•
•
Dependable
hot water available at the right moment
Sufficient
enough hot water even during peak-consumption hours
© Alfa Laval
Slide 106
www.alfalaval.com
District or Local Heating
•
District Heating
The heat from the high-pressure and high-temperature main network
flows via the 2 port valve, which regulates the primary flow through the
heat exchanger of the tap water systems and gives a variable flow rate.
Up to 25 bar & 130°C
•
Local Heating
The heat from the local boiler flows via the primary pump to the 3 or 4
port valve, which regulates the available primary temperature in the
heat exchanger and gives a constant flow rate.
Up to 10 bar & 110°C
© Alfa Laval
Slide 107
www.alfalaval.com
Instantaneous or Semi-instantaneous
Instantaneous
No connection to a storage tank; the
incoming primary heat flow heats the
secondary flow of cold water, which is
then distributed directly to the taps.
To cope with peak periods, a highercapacity of primary flow is required,
which implies a larger heat exchanger,
thus a higher boiler capacity or larger
district heating pipes.
Semi-Instantaneous
With charging pump(s) for connection to a
storage tank; the heat exchanger is
principally used to charge the tank. The
tank ensures high hot water capacity in
peak periods without having a large heat
exchanger. The primary flow can be
supplied through smaller local boilers or
district heating pipes.
© Alfa Laval
Slide 108
www.alfalaval.com
example:
How to dimension
Drain place
Standard consumption
Instantaneous hot water system
The most precise way is to conduct a drain
analysis. The total sum of all water outlets is
used to establish the total heat load:
Semi-Instantaneous hot water system
Sink
6 l/min.
ConventionalShower
12 l/min.
Shower with timer
7,2 l/min.
Bath tub
18 l/min.
Tank size
The heat load will depend on additional
variables, such as the size of the tank, the
time needed to heat the tank and the
circulation heat losses.
A drain analysis is still useful and some rules
of thumb in that context:
50 l/flat (up to 30 flats)
20 – 50 l/flat (30 – 100 flats)
20 l/flat (more than 100 flats)
Time to heat tank
1 – 8 hours (depending on size
and available power on site)
Circulation heat
losses
0.8 – 0.15 kW/flat or
100 l/stairwell
(Local conditions may influence the demand factors)
© Alfa Laval
Slide 109
www.alfalaval.com
Consumption Apartment blocks
Quantity of
Domestic Hot Water
0 am
5 am
Peak 1
10 am
3 pm
Peak 2
8 pm
12 pm
Time
Peak 3
www.alfalaval.com
Home
Alfa Laval Service
Delivery
Installation
Consulting
Training
After Sales
© Alfa Laval
Slide 111
www.alfalaval.com
Delivery
Speed
All Tap Water Systems are manufactured in Lentilly, south
east of France. Tanks are manufactured in France,
Germany and Austria. Different stock places for tanks exist in
Europe to be close to the customer.
Please contact your Alfa Laval office for delivery time of the
complete Aquarange.
Care
All Tap Water Systems are fixed on pallets, covered with
triple cardboard and a tiltwatch to avoid tipping over during
transport.
© Alfa Laval
Slide 112
www.alfalaval.com
Installation on site
Most Aqua products can be commissioned very easily just
by « Plug & Play ».
Plug
&
Play
Clear Manuals with photos and drawings available in
different languages. New languages on request.
If any help needed for installation, an Alfa Laval Service
Engineer or the Tap Water Centre can assist. Please
contact your local Alfa Laval sales company.
© Alfa Laval
Slide 113
www.alfalaval.com
Training
Possibility of Product Training:
•
at the Tap Water Centre in France
or
•
at your local Alfa Laval office
or
•
at customers site
Please contact your local Alfa Laval office
© Alfa Laval
Slide 114
www.alfalaval.com
Consulting
Helpdesk
Competent Alfa Laval employees with technical know-how to
assist you
Sales Documents
Product brochures, Drawings (pdf & autocad), Price lists,
Manuals, Certificats, Trouble shooting, Key component lists
and photo catalogue for spare parts
E-Business
Commercial & technical information and leadtimes on line for
your company. Please contact your local Alfa Laval sales
office.
Selection program CAS
Select and order the right Tap Water Product from your desk
on line. Please contact your local Alfa Laval sales office.
www.alfalaval.com
© Alfa Laval
•
After Sales
Extensive range of spares for immediate delivery out of stock
Explicit documents available to find the right spare part reference
Photo Catalogue of spares
Trouble Shooting Guide
Trained Alfa Laval Service Engineers on your site
Please contact your local Alfa Laval sales office
Slide 116
www.alfalaval.com
Home
Contact Alfa Laval
Your local Alfa Laval contact:
name…………………………
telephone……………………
mail………………………….
For more information on Tap Water Systems
www.alfalaval.com > Products and solutions / Find products / Product Categories / Tap Water Systems
E-Business account : customized Alfa Laval internet connection for your company.
Please contact your local Alfa Laval sales office
© Alfa Laval