DCN Stand Alone System - Flush Mounting Units
Download
Report
Transcript DCN Stand Alone System - Flush Mounting Units
Security Systems BU Communication Systems
Dual Audio Interface Unit
LBB 3535/00
The DAI unit can be Assigned for:
Two Delegate positions
two microphones
two loudspeakers
or
Chairman position
one microphone
priority control panel
one loudspeakers
Accepts line input
10.11.2004
DCN SA PO FMU
I&O Manual
ST/SEU-CO 1
Security Systems BU Communication Systems
Dual Audio Interface Unit
LBB 3535/00
1. 6-pole Connector for connection of
other system units (loop-through).
1
2
3
2. 2 x 3.5 mm stereo jack-plug sockets
for connection to LBB 3538/00 FM
loudspeaker panel.
3. 2 x 8-pole 262° DIN-type connectors
for connection to Microphone with
FM Control Panel LBB 3537/xx, or
standard hand held microphones
LBB 3536/x0 or the Chairman
microphone Priority Switch Panel
LBB 3537/10 to connector input1.
Notes:
- The output is switched off when the corresponding input is switched on.
- In voice-activate mode only one microphone input 2 is active!
10.11.2004
DCN SA PO FMU
ST/SEU-CO 2
Security Systems BU Communication Systems
Dual Audio Interface Unit
LBB 3535/00
Jumper setting
J2
J1
10.11.2004
DCN SA PO FMU
J1
J2
Function
Open
Open
Mic. On 1&2 (factory setting)
Closed
Open
Chairman's microphone : input 2
Priority control panel
: input 1
Open
Closed
Ambient microphone on input 2
ST/SEU-CO 3
Security Systems BU Communication Systems
Dual Audio Interface Unit
LBB 3535/00
1 1. Initialisation button (INIT) used for
2
initialising the unit during installation.
Also used to reset the unit’s address.
3 2. Input 1 and 2: ± 3 dB input level
2
4
potentiometer for fine adjustment.
3. Initialisation LED indicator.
4. Selector switch for selecting an
asymmetrical/symmetrical microphone
input
5
5. Input attenuation selection of: 0, 6, 12
or 18 dB. Factory setting: 6 dB.
6. Microphone or line level select switch.
6
Balanced audio line-input level (-12 dBV)
or microphone-input level (-60 dBV)
sources, with or without phantom
power supply.
10.11.2004
DCN SA PO FMU
ST/SEU-CO 4
Security Systems BU Communication Systems
Multi-purpose connection unit
LBB3540/15
The MPCU can be Assigned for:
One Delegate position
or
One Chairman position
or
Entrance Unit
or
10.11.2004
DCN SA PO FMU
Exit Unit
I&O Manual
ST/SEU-CO 5
Security Systems BU Communication Systems
Multi-purpose connection unit
LBB3540/15
1. 6-pole Connector for connection of
other system units (loop-through).
1
2
3
2. 2 x 3.5 mm stereo jackplug sockets
for connection to: - LBB 3538/00 FM
loudspeaker panel.
3. 2 x 8-pole 262° DIN-type connectors
for connection to: Microphone with
FM Control Panel LBB 3537/xx, or
standard microphones LBB 3536/00
and /10 or the Chairman microphone
Priority Switch Panel LBB 3537/10 to
connector input1.
Note: When two microphones are
connected (delegate mode only),both
are switched on at same time.
10.11.2004
DCN SA PO FMU
ST/SEU-CO 6
Security Systems BU Communication Systems
Multi-purpose connection unit
LBB3540/15
4. 20-pole Micromatch connector for
connection to:
- LBB 3541/00 FM Delegate voting
control panel.
4
5
6
7
- LBB 3542/xx FM Delegate/Chairman
voting control panel with
LC-display
5. 6-pole modular jack for LBB 3555/00
Intercom handset.
6. 10-pole Micromatch connector for
connection to LBB 3543/15 FM ID-Card
reader panel.
7. 2 m long cable terminated with a 6-pole
circular connector for connection to the
trunk-line.
10.11.2004
DCN SA PO FMU
ST/SEU-CO 7
Security Systems BU Communication Systems
Multi-purpose connection unit
LBB3540/15
8. Input level potentiometer: ± 3 dB.
9. Initialisation micro switch (Init) used for
initialising the unit during installation. Also
used to reset the unit’s address (De-Init).
10. Initialisation indicator (LED) indicating the
unit requires initialising.
8
9
10
11 12 13
10.11.2004
DCN SA PO FMU
11. Jumper for assigning the unit as either a
delegate or as a chairman unit.
12. Selector switch for selecting:
Asymmetrical / Symmetrical
microphone input or Symmetrical
microphone input with Phantom power
supply (applicable to both inputs).
13. Input attenuation selection of: 0, 6, 12 or
18 dB (applicable to both inputs). Default
setting: 6 dB.
ST/SEU-CO 8
Security Systems BU Communication Systems
Multi-purpose connection unit
J03
J02
J01
Solder spot J2
Open (default): Normal operation
Closed: Microphone LED-ring will
begin to flash when the last 60
seconds of speech time remains
NOTE: If J2 is ‘closed’ when the ‘Voice’
activation mode is selected, the
microphone LED-ring will remain lit when
speaking into the microphone.
10.11.2004
LBB3540/15
DCN SA PO FMU
Solder spot J3
Open (default): Normal operation
Closed: No display unit connected
ST/SEU-CO 9
Security Systems BU Communication Systems
Multi-purpose connection unit
LBB3540/15
Configuration if Assigned as:
Delegate Unit with : Microphone’s, Control Panel(s) (with or without
LC-Display), Intercom handset, ID-Card reader.
Chairman Unit with : Microphone’s, Control Panel(s) (with or without
LC-Display), Intercom handset, ID-Card reader.
Entrance Unit with : ID-Card reader, LC-Display Control panel.
Exit Unit with
10.11.2004
: ID-Card reader, LC-Display Control panel.
Jumper on topside
Chairman / Delegate
Jumper Jo1 inside unit
solder type
Function
Assigned as
Open
Open
Chairman Unit
Chairman
Open
Chairman Unit
Delegate
Open
Delegate Unit
Open
Closed
Entrance Unit
Chairman
Closed
Entrance Unit
Delegate
Closed
Exit
DCN SA PO FMU
Unit
ST/SEU-CO 10
Security Systems BU Communication Systems
FM - Microphone adjustment in DCN
Test set-up
Audio sine wave generator
Home made loudspeaker reference source “A” (see figure below)
CPSU/ CCU
AC mV meter
DCN FM
Unit
10.11.2004
DCN SA PO FMU
ST/SEU-CO 11
Security Systems BU Communication Systems
FM - Microphone adjustment in DCN
Microphone stem
When the microphone stem assembly has to be replaced, it is required that the input level of the
microphone is adjusted again by use of the preset potmeter R(x).. This due to the spread in
sensitivity of the microphone capsule (approx.. ±3dB).
Procedure
The adjustment is a practical procedure to compare factory adjusted units with units were the
microphone stem is replaced and to be tuned to the system level again.
Measurement data output and adjustments is represented by the symbol
Test procedure
1 - Connect the Delegate unit with the CCU.
Comment
.
Select mode only one active mic. on the CCU!
2 - Connect to the ‘Line out’ of the CCU the
AC mV meter
3 - Adjust the audio source to approx. 1kHz.
The audio level of the lsp. should be distortion
free and at a level of speaking distance Takes
care that no acoustic nuisance from outside
influence the measurements.
10.11.2004
DCN SA PO FMU
ST/SEU-CO 12
Security Systems BU Communication Systems
FM - Microphone adjustment in DCN
Test procedure
4 - Place the mic. of a factory adjusted
Delegate unit close to the loudspeaker on
a fixed distance.
Measure the audio level on the AC meter.
5 - Remove the factory-adjusted unit and
place the unit for adjustment in the same
position.
Read the audio level on the AC meter.
Tune R(x) to the audio ref. Default as
measured before.
10.11.2004
DCN SA PO FMU
Comment
.
Idea, make from an old DCN microphone head
housing an audio reference source.
Mount inside the (empty) head e.g. a paging
bleeper as ref. loudspeaker.
Important is that for all measurements the
distance between loudspeaker and microphone
is equal.
Take this level as ref. for the DCN FM units to be
adjusted. Repeat the ref. measurement for a
check with other unit(s).
The factory level adjustment is ±0.5dB
Do not change the audio setting adjustments.
For the LBB3537/xx, tune the +/- 3dB adjustment
potmeter of the LBB3535/xx or LBB3540/xx
ST/SEU-CO 13
Security Systems BU Communication Systems
DCN Voting Unit Range
10.11.2004
DCN SA PO FMU
I&O Manual
LBB4141/x0
LBB4141/00 Voting Panel
LBB4141/50 Voting Panel
Chinese
ST/SEU-CO 14
Security Systems BU Communication Systems
DCN Voting Unit
LBB4141/00
10.11.2004
DCN SA PO FMU
Allows three types of voting:
parliamentary
multiple choice (1-5)
audience response (++,+,0,-,--)
LED vote confirmation indicators
LED unit active indicator
Pimple for locating third button
ST/SEU-CO 15
Security Systems BU Communication Systems
DCN Voting Unit Chinese Version
10.11.2004
DCN SA PO FMU
LBB4141/50
Allows parliamentary voting
Colored voting buttons
Chinese text
LED vote confirmation indicators
LED unit active indicator
Pimple for locating “Yes” button
ST/SEU-CO 16
Security Systems BU Communication Systems
DCN Voting Unit
LBB4141/00
1
2
3
4
1 De-init/init switch
for de-initialization and initialization of the unit
2 Button order jumper for setting the voting button order for parliamentary
voting
3 DCN cable
1 meter DCN cable with male connector
4 DCN cable
1 meter DCN cable with female connector
10.11.2004
DCN SA PO FMU
ST/SEU-CO 17
Security Systems BU Communication Systems
DCN Voting Unit
1
LBB4141/00
2
1 Jumper Position 1 – for Parliamentary Voting
2 Jumper Position 2 – for Multiple Choice (1-5) and for
Audience Response (++,+,0,-,--)
Note :
The default position of the button order jumper is position 2
10.11.2004
DCN SA PO FMU
ST/SEU-CO 18
Security Systems BU Communication Systems
End Caps
Couple Pieces
10.11.2004
DCN SA PO FMU
(Set of 50 Pieces)
LBB4125/00
(Set of 50 Pieces)
LBB4127/00
ST/SEU-CO 19
Security Systems BU Communication Systems
DCN Flush Mounting Units
End of section
Robert Bosch GmbH
All rights are reserved. Reproduction or passing on to
third parties in whole or in parts is prohibited without the
written consent of the copyright owner.
10.11.2004
DCN SA PO FMU
ST/SEU-CO 20