KITS and ACCESSORIES - Аирконд

Download Report

Transcript KITS and ACCESSORIES - Аирконд

J-series Chillers KITS and ACCESSORIES
Product Presentation
Public
New Chiller Accessories
Daikin Name
EKAC200J
EKACBAC
EKACLON
EKCON
EKCONUSB
EKMODEM
EKGSMOD
EKBMSBNJ
EKRUPCJ
EKRUPCK
EKCSCII
EKPV2J
EKBT500N
EKBTC10N
EKBT500C
EKBTC10C
EWAD..AJ
o
o
o
o
o
o
o
o
o
o
o
o
o
o
EWYD..AJ
o
o
o
o
o
o
o
o
o
o
o
o
o
o
EWAD..BJ
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
EWAP..AJ
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
EWWD..DJ
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
EWWD..CJ
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
EWWD..BJ
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o = available option
18-Jul-15
2
Public
EKAC200J: RS485 Serial Address Card
Three different connection possibilities exist:
 BMS: MODBUS needs an EKAC200J per connected chiller. No gateway.
 BMS: BACnet PTP (Point to Point) protocol requires an EKAC200J per connected
chiller and an EKBMSBNJ gateway. BACnet PTP is a low level Class 2 BACnet.
 RS485: All other communication or plant management accessories requiring RS485
or RS232 communication require an EKAC200J per connected chiller.
Unit 1
Unit 2
EKAC
Unit 3
EKAC
Unit ..
EKAC
RS485 Supervisory Network
RS485: MODBUS Protocol
Gateway
EKBMSBNJ
KEY
EKAC
BACnet PTP
(Class 2)
RS485 Serial Address Card
EKAC200J
Supervisory system
Eg: Chiller Sequencing
Control EKCSCII
18-Jul-15
3
Public
EKACBAC
 Ethernet Address Card for Class 4 BACnet communication with a BMS system.
Each connected chiller requires an Ethernet card. No gateway is needed.
Unit 1
Unit 2
EKAC
Unit 3
EKAC
Unit ..
EKAC
KEY
EKAC
18-Jul-15
Ethernet Address Card
EKACBAC
BACnet (Class 4)
4
Public
EKACLON
 LON FTT Address Card for LON communication with a BMS system. The card is
supplied preloaded with the respective LON xif chiller profile.
Unit 1
Unit 2
EKAC
Unit 3
EKAC
Unit ..
EKAC
KEY
EKAC
18-Jul-15
LON FTT Address Card
EKACLON
LON Protocol
5
Public
Tele-communication
 EKMODEM: Fixed Line Modem for remote monitoring of the chiller plant. A maximum
of 32 chillers can be connected to a single modem. The modem communication protocol
is RS232 and an EKAC200J and EKCON are necessary.
 EKGSMOD: GSM Modem for remote monitoring of the chiller plant. A maximum of 32
chillers can be connected to a single modem. The modem communication protocol is
RS232 and an EKAC200J and EKCON are necessary.
Unit 1
EKAC
Unit 2
EKCON
EKAC
EKCON
Unit 3
EKAC
Unit ..
EKCON
RS232 Supervisory Network
Fixed Modem
EKMODEM
KEY
18-Jul-15
EKAC
RS485 Serial Address Card
EKAC200J
EKCON
RS485 to RS232 Converter
EKCON
GSM Modem
EKGSMOD
Supervisory system
Eg: Plant Visor EKPV2J
6
Public
Remote User Interfaces
 EKRUPCJ: Remote control interface for EWAD~AJYNN. This interface can be
located upto 500m from the unit.
 EKRUPCK: Remote control interface for other ranges. This interface can be
located upto 500m from the unit.
pLAN
EKRUPCJ or
EKRUPCK
Unit 1
18-Jul-15
7
Public
EKCSCII: Chiller Sequencing Control
Separate control panel to allow the sequencing of a group of chillers (max 5) as
a single plant for optimised power management and energy flow balancing.
 Chiller sequencing (Max chillers = 5)
 Cooling towers sequencing control (Max Towers = 5 each with 2 steps)
 Chiller sequencing
 Primary pump control (Max Primary pumps = 1)
 Secondary pumps control (Max Secondary Pumps = 5, with upto 2 inverter driven)
 Secondary circuit bypass valve control
 Chilled water circuit bypass valve control
 Set point override
 Demand limit
 Double set point
 Unit turnover
 BMS connectivity (Carel, Modbus, LonWork, BACnet)
 Remote On/Off
18-Jul-15
Note: See separate EKCSCII presentation
8
Public
EKPV2J: Plant Visor 2
For local monitoring (PC) of each chiller or remote monitoring via modem
(EKMODEM or EKGSMOD) with the PlantVisorTM supervision program.
Compatible with Windows 2000 2nd Edition and Windows XP. Both local
and remote monitoring is by RS232 communication.
The main monitoring and control features are:
 Unit status monitoring
 Circuit status monitoring
 Modification of setpoints
 Display of Alarms
18-Jul-15
9
Public
Hydraulic Kits: Buffer Tanks
 EKBT500N: 500l naked buffer tank on metal base frame.
 EKBTC10N: 1000l naked buffer tank on metal base frame.
 EKBT500C: 500l buffer tank with cabinet on metal base frame.
 EKBTC10C: 1000l buffer tank with cabinet on metal base frame.
EKBT***N
EKBT***C
Plan View
Naked Buffer Tank on Base Frame
18-Jul-15
Buffer Tank with cabinet in RAL7032
10
Public
Engineered for flexibility and performance.™
18-Jul-15
11