Eaton 93E 80-400kVA UPS Sales Presentation © 2013 Eaton Corporation. All rights reserved. 93E Product Snapshot Power Rating: 80, 100, 120, 160, 200kVA 300kVA, 400kVA Topology: Double-Conversion, Transformer-Free with High Efficiency Mode Input/Output Voltage: 230/400 4 Wire Frequency: 50/60 Hz Features: Hot Sync® ABM® High Efficiency Mode Easy Capacity Test © 2013 Eaton Corporation. All rights reserved. 2 Summary of Major Features & Customer Benefits • High density: Small Footprint reduces space required for UPS • Hot Sync paralleling: No common control system means increased reliability • Advanced Battery Management: Enhances battery life, safety and makes batteries more predictable • Front Service Access: Reduced service time and costs, less space required • Optional Internal Switchgear: Flexibility, reduced need for external switchgear • Optional internal Back-feed Contactor: Enhanced safety and reliability • Easy Capacity Test: No need for load banks, reduces total cost of ownership over UPS life © 2013 Eaton Corporation. All rights reserved. 3 93E Compact Footprint 200kVA Configuration Vs global competitors Product Dimensions (cm, W x D x H) Footprint (m3) 93E 60 80 188 0.48 Competitor A 141 85 190 1.20 Competitor B 97.5 85.8 190 0.84 Competitor C 60 84.3 160 0.51 Competitor D 70 80 193 0.56 Up to a 60% smaller footprint! 1880 800 600 All 80-200kVA models feature same dimensions © 2013 Eaton Corporation. All rights reserved. 4 93E Compact Footprint 400kVA Configuration Vs global competitors Product Dimensions (cm, W x D x H) Footprint (m3) 93E 160 82 188 1.31 Competitor A 165 85 190 1.40 Competitor B 167.5 88 190 1.44 Competitor C 150 100 160 1.50 Competitor D 160 99.5 193 1.59 1880 820 1600 Up to a 18% smaller footprint, including top and bottom cable entry capability! (Competitors require additional footprint) © 2013 Eaton Corporation. All rights reserved. 5 HotSync® paralleling technology Provides industry leading hardware availability • Modular scalability for capacity • N+1 redundancy – up to 4 modules in parallel Strengths • Peer to peer paralleling • Independent load sharing • No single-point-of-failure • Patented, unique load sharing technology © 2013 Eaton Corporation. All rights reserved. 6 93E Paralleling • Up to 4 Systems in parallel in a 3 + 1 Configuration • Optional Module Output Breaker (MOB) signal wiring enhances functionality: • Enables individual UPS to be isolated from system and tested functionally without affecting the rest of the system • Optional standard “Line up and match” System Parallel Modules Parallel System Communications Cabling Diagram © 2013 Eaton Corporation. All rights reserved. 7 ABM® battery charging • Less internal battery corrosion due to resting period • Monitors battery charge level • Alarms and back-up time calculation • Allows users to anticipate end of battery life • Automatic discharge testing • Back-up time calculation • Battery is continuously monitored Back-up time/capacity Up to 50% longer battery life time with ABM technology! 2.35 V 2.28 V VB / Cell alarm level 2.1 V 12 2 days 28 days charging resting period period 24 36 ... Time / 12 months 2 days charging period ABM technology time © 2013 Eaton Corporation. All rights reserved. Traditional float charging 8 Efficiency With its high-efficiency mode the 93E can operate at up to 98.5% efficiency If customers are operating with a legacy UPS system, the 93E can deliver substantial cost savings. © 2013 Eaton Corporation. All rights reserved. 9 Eaton HE Mode versus ECO Modes Eaton's HE Mode offers higher efficiency as well as: • Surge Protection – Inherent filtering with transformer-free technology • Fast Transition Time for risk free operation - Performs rapid detection and correction of power disturbances well below 4ms, maximum 10ms (ECO modes typically 8ms to 15ms on competitive products) • Fault Detection provides extra security – Detects difference between load fault and upstream source fault • Downstream fault cleared with increased short circuit capability remaining in high efficiency mode • Upstream fault cleared by immediately disconnecting from the utility fault HE Mode provides risk-free high efficiency! © 2013 Eaton Corporation. All rights reserved. 10 Eaton HE Mode Advantages • Lower duty cycle for rectifier and inverter: Improves reliability and MTBF • Fans are typically off: Reliability of one of the few moving parts in the UPS is enhanced. Contrast with flywheel-based high efficiency systems , or line interactive systems • Audible noise is reduced: Fans and PWM are off • Load inrush handling is enhanced: Due to lower impedance of utility source vs. inverter. This is good for motor loads and medical imaging applications © 2013 Eaton Corporation. All rights reserved. 11 Easy Capacity Load Testing Easy Capacity Test uses the UPSs Rectifiers and Inverters as an internal load bank. A field engineer can easily perform tests with a service laptop No load banks to rent! No load connections needed! No wasted energy! Load test capability saves customers time and money! © 2013 Eaton Corporation. All rights reserved. 12 Display – Graphical LCD Status Bar LEDs: On Mains Navigation buttons On Battery On Bypass Fault Status Bar: • Meters Events History Controls Setup Automatically scrolls between model number, date/time, active alarms, UPS status, load % and battery runtime Meters: • • • • Input: V Ph-N, V Ph-Ph, I/Ph, Hz, kW, kVA, pf Output: V Ph-N, V Ph-Ph, I/Ph, Hz, kW, kVA, pf Bypass: V Ph-N, V Ph-Ph, I/Ph, Hz, kW, kVA, pf Battery: V, I, Time remaining bargraph © 2013 Eaton Corporation. All rights reserved. Event History: 512 Events User Controls: • • • Bypass Command Battery Test Display Test Setup: • Clock, Language, Lamp Test etc 13 93E Serviceability The 93E was designed to reduce mean-time-to-repair to less than 30 minutes! • Front Service Access • Slide Out Modules/Trays • Modules weigh less than 25kg Washable Dust Filters • Optional Integral Maintenance switch for 80-120kVA • Washable Dust Filters Note: UPS in picture is a prototype, final versions do not have a cover plate over the communications panel. © 2013 Eaton Corporation. All rights reserved. 80-120kVA 14 Communications Panel Communication cable entry points Mini Slot 1 Building Alarms (3) REPO (NO & NC) Pull Chain Mini Slot 2 Parallel CAN Input (RJ45) Parallel CAN Output (RJ45) RS232 & USB Ports (for service access only) are located on front door control PCB © 2013 Eaton Corporation. All rights reserved. In-built CAN bridge eliminates need for Hot Sync card! 15 Standard UPS Configurations: 80-120kVA 1 Standard Configuration 2 Optional Maintenance Bypass 3 Optional Maintenance Bypass with Backfeed Contactor 1 3 2 Single source bridging links are supplied with the UPS © 2013 Eaton Corporation. All rights reserved. 16 80-120kVA Internal Maintenance Bypass • Electro-mechanically interlocked bypass Metal interlock slides to the right to force UPS to static bypass and enable bypass switch to be closed and inverter output switch to be opened © 2013 Eaton Corporation. All rights reserved. Metal interlock prevents neutral switch from being opened (must always be closed except when service personnel are maintaining UPS 17 Standard UPS Configurations: 160-400kVA 160-400kVA Dual Input with no switches 1 Standard Configuration 2 Optional Input Switch 3 Optional Input Switch and Backfeed Contactor 1 160-400kVA Dual Input, optional 3 pole input switch 160-400kVA Dual Input, Input switch & backfeed contactor 3 2 Single source bridging links are supplied with 160-200kVA UPS © 2013 Eaton Corporation. All rights reserved. 18 Battery Configuration • Default setting = 40 Blocks • Configurable: 36 or 38 Blocks • Charging current: • 80-120kVA: Maximum 40A Blocks Shut down voltage 36 x 12V 1.80V/cell 38 x 12V 1.73V/cell 40 x 12V 1.67V/cell • 160-200kVA: Maximum 80A • 300-400kVA: Maximum 160A • External Battery CB: • Standard MCCB, no Shunt Trip or Under Voltage Release required • Two Wire connection (+ & -) © 2013 Eaton Corporation. All rights reserved. 19 93E Software and Connectivity Easy manageability and monitoring…. 2 MiniSlots available for additional connectivity hardware • WEB/SNMP, Relay/RS232 Card, Modbus card & Industrial Relay card options 3 Building Alarm Inputs and dedicated EPO • • Building alarms can be programmed to display the alarm functional name Emergency Power Off port accommodates Normally Closed and Normally Open inputs RS232 & USB ports • RS232 & USB ports for service interface Software Capability • Eaton Intelligent Power® Manager © 2013 Eaton Corporation. All rights reserved. 20 Intelligent Power Manager • Supervisory Software • Free for Monitoring up to 10 devices • Delivers a global view of power devices across the network from any PC with an Internet browser • Enables single, Web-based interface for remote monitoring and management of: • Eaton® and other manufacturers’ UPSs • Environmental sensors • ePDU® products and more © 2013 Eaton Corporation. All rights reserved. 21 © 2013 Eaton Corporation. All rights reserved. 22