Counters and Registers
[email protected]
7-4 Asynchronous (Ripple) down
counter
23=8 ---> MOD-8 Down Counter
7-5 Propagation Delay in Ripple
Counters
Ripple counters are the simplest type of
counters.
Although they are simple, they have a major
drawback which is the propagation delay
caused by their operation principle.
7-5 Propagation Delay in Ripple
Counters
7-5 Propagation Delay in Ripple
Counters
7-5 Propagation Delay in Ripple
Counters
To avoid this problem, we should make sure of the
following:
TClock N t pd
f max
1
N t pd
N = number of FFs
Tpd = propagation delay time
Example
A 4-bit Ripple counter with tpHL= 16 nS and tpLH=
24 nS, using 74LS112 J-K FF. find the maximum
frequency for a proper operation of the counter.
Assume a worst case scenario
1
1
f max
10.4 MHz
N t pd 4 24nS
For 6-bit Ripple counter that has 6 FFs.
1
1
f max
6.9MHz
N t pd 6 24nS
7-6 SYNCHRONOUS
(PARALLEL) COUNTERS
The synchronous counters have all of the
FF’s triggered simultaneously. That is, all
the CLK inputs are connected together
Synchronous counters require more
circuitry than the asynchronous counters.
Synchronous counters needs extra logic
gates to be added.
7-6 SYNCHRONOUS
(PARALLEL) COUNTERS
Each FF should have its j and k inputs connected such that they
are HIGH only when the outputs of ALL lower-order FFs are in
the HIGH state
7-6 SYNCHRONOUS
(PARALLEL) COUNTERS
Each FF is clocked by the NGT of
the clock input signal so that all the
FF transitions occur at the same time.
Only A has its J-K inputs
permanently at the HIGH level.
A changes at each NGT clock (A
FF toggles)
B changes when A=1 and a NGT
clock occurs
C changes when A=B=1 and a
NGT clock occurs
D changes when A=B=C=1 and
a NGT clock occurs
Advantage of synchronous
Counters over Asynchronous
In a parallel counter, all FF will change
simultaneously.
Propagation delay of FF do not add together to
produce the overall delay.
Total delay = FF tpd + AND tpd
Fmax = FF Fmax+AND Fmax
The total delay is the same no matter how many
FF are used.
A synchronous counter can operate at much higher
frequency, but the circuitry is more complex than
that of the asynchronous counter.
Example
Determine fmax for the synchronous MOD16 counter if tpd=50ns for each FF and
tpd=20ns for each AND gate.
1
f max
14.3MHz
50 20
Determine the equivalent fmax for
asynchronous MOD-16 counter
1
f max
5MHz
4 50
Example
What must be done to convert this counter to
MOD-32 parallel counter?
A Fifth Flip-Flop must be added “25=32”
Determine fmax for the MOD-32 parallel
(synchronous) counter
1
f max
14.3MHz
50 20
For a MOD-32 ripple counter
1
f max
4MHz
5 50
Unchanged