Transcript Document
HIPPS - High integrity
pressure protection system
Example system to be used in
PK6022
DCV = Directional control valves
• Electrically (solenoid) operated directional
control valves, sometimes referred to as
solenoid valves or just DCVs
• In the following, we refer to these valves as
DCVs.
HCV = hydraulic control valves
• Pilot operated DCVs, where the pilot
signal may be hydraulic or pneumatic
pressure
• The valves may also be referred to as
hydraulic control valves (HCVs) or
hydraulic dump valves (HDV)
• In the following HDV is used
Component
Pressure transmitter
𝜆𝐷𝑈
Value
= 0.3 ∙ 10−6 /ℎ𝑟
𝜆𝐷𝐷 = 0.5 ∙ 10−6 /ℎ𝑟
Source
PDS data handbook
(2010)
𝜆𝑆𝑈 = 0.4 ∙ 10−6 /ℎ𝑟
Logic solver
𝜆𝐷𝑈 = 0.8 ∙ 10−6 /ℎ𝑟
𝜆𝐷𝐷 = 7.2 ∙ 10−6 /ℎ𝑟
PDS data handbook
(2010)
𝜆𝑆𝑈 = 6.4 ∙ 10−6 /ℎ𝑟
Solenoid/pilot valve
𝜆𝐷𝑈 = 1.6 ∙ 10−6 /ℎ𝑟
𝜆𝐷𝐷 = 0.6 ∙ 10−6 /ℎ𝑟
HIPPS valve
PDS data handbook
(2010)
𝜆𝑆𝑈 = 3.4 ∙ 10−6 /ℎ𝑟
(pilot/solenoid valve x 2)
𝜆𝐷𝑈 = 2.1 ∙ 10−6 /ℎ𝑟
PDS data handbook
(2010)
𝜆𝐷𝐷 = 0.9 ∙ 10−6 /ℎ𝑟
𝜆𝑆𝑈 = 2.1 ∙ 10−6 /ℎ𝑟