Start Up
Procedures and
Recommendations
for Factory
Authorized
Equipment Start Up
1
Prepare Before You Go!
Review all documentation
Call the contractor
Keep notes
Bring contact names and phone numbers
2
Prepare Before You Go!
Has the plumbing been completed?
Has the system been pressure tested?
Has the resin and gravel been loaded?
3
Prepare Before You Go!
Has
the electrical been
completed?
Are
vessels full of water?
Does
he know of any
problems during installation?
4
Show Up,
Meet, and
Greet
5
Things to Check - Piping
Review piping with Plumbing
Contractor (Let him explain it)
Does it match Piping
Diagram?
Are the shut off kits correctly
installed?
Check tubing. Is it run
correctly?
6
Things to Check - Piping
Is the manual bypass valve
in the correct location?
Is drain piping correctly
sized?
Are the flow meter(s)
positioned correctly?
7
Things to Check – Brine System
Is the brine tank correctly installed?
Make certain the float is not
dragging in the brine tank.
Is the water level up to the float in
the brine tank?
Is the external injector properly
installed? (for larger systems)
8
Things to Check - Electrical
Review electrical with
electrical contractor (Let him
explain it)
Double check wiring.
Does it match electrical
drawings from manuals?
Check terminals strips for
correct locations and
tightness.
9
Things to Check - Controls
Control Valves
Electronic Demand Regenerator (EDR)
Program at this time
Flow Meter
Solenoid Valves (ASCO)
10
Ready
to
Go . . . .
11
Getting Started
Close Outlet Valves
Open Bypass Valve
Open Inlet Valves (s l o w l y)
Vent each Vessel
Power Up
12
After Power is Connected
Make certain every thing works.
On twin system, one unit will go to stand
by.
13
ASCO will energized & get warm. Diaphragm
Valve will be closed. Check with paper clip. If
it goes in more than 1 ¼, valve is open.
Warm ASCO, Valve should be closed.
Work with
the Unit in
Stand By
14
Manually Start Regeneration
from Timer
Piston will move to backwash cycle.
Check flow to drain.
Watch for resin in drain.
Water may be discolored. (color throw)
Does flow match O & M?
Do not leave in this cycle longer than one
minute.
15
Advance Timer to Brine Draw
Position
16
Is water level in Brine Tank moving down?
Advance Timer to Fast Rinse
Position
Check flow to drain.
Does flow match O & M?
Watch for resin.
Water may be discolored. (color throw)
Do not leave in this cycle longer than one
minute.
17
Advance timer to Service
Position
18
Repeat short cycles until water to drain is
clear
Repeat
with Other
Units
19
Place System Online
Ask operator for permission to open
outlet valves.
Open outlet valves slowly.
Close Bypass Valve.
Water pressure should stabilize.
20
Check Operation of EDR II
Verify water flow from EDR
Re-program EDR preset to 1 to start a
regeneration.
Verify that 3-minute start signal was sent
from EDR II to Taskmaster control valve.
Re-program EDR II with presets to
original calculations.
21
Final Equipment Check
Make certain both outlet valves are open.
Check system unit over completely.
22
Training
Explain the process and operations to the
operator.
Show them how to use the operations
manual to their benefit.
Answer all questions.
23