Transcript Document
NATURAL GAIT INDUCING
TRANSTIBIAL PROSTHETIC
LUCIA MELARA
ROBERT SCOTT
ALEXIS GARO
EML 4551 ETHICS AND DESIGN PROJECT ORGANIZATION
FIU DEPARTMENT OF MECHANICAL ENGINEERING
MIAMI, FL
PROBLEM STATEMENT
Current prosthetics produce secondary disabilities
Back complications
Metabolic problems
Passive prosthetics cannot dynamically adjust “push off” force
“Active” prosthetics exist however are impractical
High cost prevents access to most patients
Majority of transtibial amputees are impoverished
3-6 month adaptation period
EXISTING POWERED PROSTHETICS
AMP Foot 2
BIOM T2 System
PROJECT OBJECTIVES
Design an ankle prosthesis able to actively adjust “push off” force
Reduce cost to achieve higher cost efficiency than industry average
Increase walking range on single charge to 4 kilometers
Design actuation system to allow quick changes of drive motor(s) and springs
5 pound maximum system weight
ENGINEERING STANDARDS
FDA: Center for Devices and Radiological Health
Class I device per Code of Federal Regulations
Title 21 Section 890.3420
FDA ensures patient safety with device
Device not subject to specific restrictions
ASTM standards for used material values
Aluminum Association referenced for material selection
HILL TYPE MUSCLE MODEL
Mathematical model which views a muscle as spring like structure
Consists of contractile, series, and parallel elements
Produces torque values in reference to angle
Compared to values for natural ankle
HILL TYPE MUSCLE MODEL
HILL TYPE MUSCLE MODEL
ACTUATOR DESIGN ANALYSIS
PROPOSED SOLUTION
Use data from sensors to determine the appropriate torque curve
Compensate for walking speed, slope, terrain changes
Predict user’s next step using predictive algorithms and sensors
“Echo Location” control approach to learn from opposite leg
Higher efficiency actuator system
Lighter, higher efficiency batteries
More efficient actuator system implementing an SEA+UPS system
SOLIDWORKS MODEL
GLOBAL DESIGN INTEGRATION
Modularity
Prosthesis can be combined with different knee prosthetics
Replaceable batteries
Interchangeable motor unit
Simple design that can be manufactured without a CNC machine
3D printed enclosure
Research paper to be published
PROJECT TIMELINE
CONCLUSION AND FUTURE WORK
Completed:
Motion analysis of human gait cycle
Proposed designs
To be done
Complete actuator design analysis on proposed designs
Perform simulation studies
Manufacture first prototype
Perform metabolic and range tests at secured testing facility
QUESTIONS?