下載/瀏覽

Download Report

Transcript 下載/瀏覽

微波電路期中報告
論文研討:
John C. Webber、Marian W. Pospieszalski,
“Microwave Instrumentation for Radio
Astronomy”,IEEE TRANSACTIONS ON MICROWAVE THEORY AND
TECHNIQUES, VOL. 50, NO. 3, MARCH 2002
報告人:
碩研電子一甲 MA030217
Southern Taiwan University
陳力源
Department of Electronic Engineering
摘要

Radio astronomy is a branch of science that allows
observation of natural radio signals from cosmic sources.

Microwave techniques are employed in large radio
telescope systems.

Index Terms—Amplifiers, radio astronomy, radio receivers,
superconductor–insulator–superconductor mixers.
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
1
MARCH 2002
Radiometers
(a) Resistor at temperature T. (b) Antenna in an absorbing box at
temperature T. (c) Antenna observing sky at temperature T (after [2]).
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL.
2
50, NO. 3, MARCH 2002
Simplified block diagram of a total power receiver.


from antenna theory that Upon substitution of (3) into (2), (1)
is obtained, i.n., the available noise power at the ideal
antenna terminals of Fig 2.
---(3)

---(2)

---(1)
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
3
MARCH 2002
Geometry of a simple two-element interferometer
Geometry of a simple two-element interferometer
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
4
MARCH 2002
LOW-NOISE DEVICES
A.General Remarks

The quest for ultra-low-noise reception is especially
important for radio astronomy

as the receiver noise is usually a significant part of
the system noise
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
5
MARCH 2002
LOW-NOISE DEVICES
B.HFET Amplifiers

the technology of InP devices has matured and
allowed practical use.

Hybrid “chip and wire” amplifiers have been
demonstrated up to frequencies of 118 GHz
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
6
MARCH 2002

Comparison of noise temperature
of NRAO cryogenic receivers
using InP HFET amplifiers cooled
to approximately 20 K and SIS
mixer receivers cooled to 4 K.
Fig. 4.
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
MARCH 2002
C. SIS Mixers

An SIS mixer employs a superconducting tunnel junction as the nonlinear
mixing element.

A high-quality SIS mixer can have a noise temperature ( 5 K at 100 GHz)

Modern SIS mixers normally use Nb junctions, which give good results
when cooled to 4.0-K physical temperature

Junction sizes are typically a few square micrometers, and critical current
densities are typically a few thousand A/cm .

an IF bandwidth of 1 GHz, with the exception of an approximately 3GHz
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
8
MARCH 2002

a balanced SIS mixer has the same
advantages as a balanced conventional
mixer: reduction of the required LO
power and canceling of the LO sideband
noise downconverted into the IF band.

A balanced SIS mixer using niobium
MMIC technology has been demonstrated
at 200–300 GHz
Example of noise performance of a fixed-tuned SIS
mixer (discrete points) and the entire receiver (solid line)
for 200–290 GHz
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
9
MARCH 2002
EXAMPLES OF RADIO ASTRONOMY RECEIVERS
A.HFET Receiver

A critical area in very low-noise receiver design is a
low-loss coupling between an ambient temperature feed
horn and a cryogenic amplifier.

The VLBA front-ends use a gapped circular waveguide
transition from the feed to a cooled polarizer located
within the vacuum Dewar.
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
10
MARCH 2002
B. SIS Receiver

SIS mixer receivers are typically employed above
frequencies of about 100 GHz.

The radiation into the mixer are the same as for HFET
receivers,made even more difficult by smaller
dimensions and tolerances as the frequency is increased.

Double-sideband receiver noise temperatures of
approximately 20 K have been reported near 100 GHz for
Nb SIS mixer receivers
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
11
MARCH 2002
C. MAP Radiometer
Simplified block diagram of a MAP satellite pseudocorrelation radiometer
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
12
MARCH 2002
Inner portion of the VLA in its most
compact configuration
100-meter Robert C. Byrd GBT
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
13
MARCH 2002
結論

本文內容對我自己幫助也很大 ,Microwave
Instrumentation for Radio Astronomy, 運作方法需要
電子學知識, 電磁波傳遞與接收, 需要使用微波工程內
容,,所以是一個十足有趣的領域。
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
14
MARCH 2002
參考文獻
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
15
MARCH 2002
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
16
MARCH 2002
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
17
MARCH 2002
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 50, NO. 3,
18
MARCH 2002