Transcript Scheduling
Mobile Testing & Calibration Service Certificate No 15281 National Association of Testing Authorities Testing Calibrations Repairs Inspections Sales Data Management Scheduling Why TEX Onsite TEX Onsite is Australia's market leader in mobile testing and calibration services with a network of technicians covering all states of Australia. Our comprehensive scope allows us to test and/or calibrate a large range of equipment at your sites with the aim for TEX Onsite to be the only call you need to make for all your needs. We have a dedicated R&D team who are at your service to provide solutions when our scope needs to be increased to fulfil your needs, plus an electronic repair laboratory to look after many items requiring attention. TEX Onsite is NATA Accredited (No 15281) to provide confidence, quality and stability across your business wherever you are in Australia. Our regional managers give you a single point of contact for each area and ensure that we understand any local issues or requirements. This allows us to provide a flexible service to deliver the product required to exceed your expectations Mick Kirwan Managing Director Grant Mounsey Chief Technical Officer Jeremy White Chief Operating Officer Chris Kenihan R&D Manager Errol Dunn National Business Development Mgr Dwayne Sparkes Chief Financial Officer Tristrum Pradun IT Officer Sarah Clarke Company Accountant David Li IT Engineer Chris Roussos Technical Consultant Kristy Cahill Credit Controller Paul Mycroft Trainer/Auditor Emma Pine Administrator Eddie Wust Business Relationship Mgr Jeremy Hurley Chief Pilot > the team TEX Onsite organisational structure Australia Jason McLean TBA Regional Manager West Regional Manager South Bruce Fisher Electrical Tester Ryan Burl Electrical Tester Shaun Porter Electrical Tester Craig Thompson Darryl Briggs Regional Manager Central Regional Manager North Jim Legg Laboratory Manager Keith Moss Electrical Tester Graeme Ward Calibrator Dermott Blackwell Calibrator Salim Helis Electronics Repair Tech Brett McCabe Electrical Tester Mackay Electrical Tester Jordan Roddy Pilot Technician Paul Loughnan Electrical Tester Jesse Vince Instrument Repair Tech Peter Lucas Electrical Tester TBA Electrical Tester Steven King Pilot Technician Tim Duncan Apprentice Calibrator Jessica Traynor Electrical Tester Peter Graham Electrical Tester Mark Argent Electrical Tester Paul Drayton Electrical Tester Neville Lyons Electrical Tester Chris Forward Electrical Tester Kris Capewell Pilot Technician Chris Kerr Calibrator Wayne Wicks Electrical Tester Steve Penfold Pilot Technician Peter Leahey Electrical Tester Gavin Rae Pilot Technician Terry Toner Neil Taylor Pilot Technician Areas of expertise: Mobile electrical testing up to 200KV AC on site for: ( Insulating Gloves/Sleeves/Mats, Hard Covers, Line Sticks, Live Line Equipment, EWP Units & Liners, Oil, Indication Meters, Probe Testers, Portable Earths ) Mobile Instrument Calibration: (most hand held electrical instruments, oscilloscopes, high pot and VLF sets, vernier, micrometer, temperature control ) Pressure Calibration: Pressure – Vacuum and pressure ranging up to 10,000psi (700bar), Accuracy up to 0.01% Torque Calibration: Torque - calibration available up to 1500Nm (Newton metres) which equals about 1100 lbft (Pound Foot) Inspections: harness, line belts, pole strap, ladders Portable Appliance Testing: Testing and Tagging of portable electrical appliances used in the workplace. These requirements are based around Australian Standards and are legislated so that all workplaces must comply. Dimensional Measurement Equipment Calibration: Flatness 0.15µm, Parallelism 0.4µm, Grade AA gage blocks, Dial gages 15mm (0.600") Range, 0.001mm (0.00005") Resolution, Lifting Equipment Inspection: Webbing Slings, Chains, Wire Rope Slings, Hooks and Shackles, Hand Operated Chain Blocks Autoclave Validation: Temperature: ±0.05 °C, Pressure: ±0.25% full scale, Up to +150 °C Areas of expertise: Power System Protection Maintenance - Through a unique and effectual alliance with Protection System experts Electre Consulting, TEX Onsite provides a rapid response Protection Relay Maintenance Service to the site – anywhere in Australia. Generation & Transmission System Protection Design Service The Electre / TEX Onsite alliance allows for rapid response power system protection design expertise delivered Australia wide, ensuring protection installations are continually monitored and are always up to date. Infrared & Thermal Imaging Calibration: Stability, ± 0.05 °C at 35 °C, ± 0.20 °C at 200 °C, ± 0.40 °C at 500 °C, Accuracy for 8 µm to 14 µm emissivity set between 0.9 and 1.0, ± 0.35 °C at 35 °C, ± 0.50 °C at 100 °C, ± 0.70 °C at 200 °C, ± 1.20 °C at 350 °C, ± 1.60 °C at 500 °C, Emissivity 0.95, Uniformity of approximately 0.1°C Temperature Calibration: Accuracy ± 0.03°C up to 650°C, Stability ± 0.06°C up to 650°C, Uniformity ± 0.06°C up to 650°C Repairs : ( rubber products, portable earths, fibreglass sticks and Electronic instrument fault finding and repair ) Sound Level Meter Calibration: Frequency 1000 Hz ± 2 %.Sound Pressure Level94 dB ± 0.75 dB. 114 dB ± 0.9 dB. Total harmonic distortion94 dB range ± 2 %. 94 dB range ± 2 %. Suitable Microphone Type0.5 inch or 1 inch microphone. Chemical Testing: Conductivity, pH, Relative Humidity, Total Dissolved Solids (TDS), Redox Areas of expertise: Thickness Gauges: Ultrasonic thickness gauges from 1.5 to 20mm (accuracy of 4µm). Paint thickness gauges from 80µm to 400µm (accuracy of 0.25µm) Surveying Equipment Laser Levels, Dumpy Levels, Engineers Levels, Clinometers and Theodolites Weight s and Measures Calibration 0.02% accuracy for on-site scales up to 200kg, 0.005% accuracy for scales up to 65kg, 0.005% accuracy weights up to 65kg (Non-commercial applications only) Water Meters – Verification and Validation of flow meters to ATS4747 including in-situ calibration. 1% Basic accuracy In-situ Flow meter calibration – Ultrasonic in-situ calibration of liquid flow meters including closed loop system for mine site fuel farms and fuel tender trucks Ultrasonic Pipe Wall Thickness Surveys – Measuring range 200mm. Accuracy 0.1mm. Linearity 0.1mm In-situ process control instrument calibration – shutdown and maintenance mode instrument and scada system calibration Engineering Consultancy – Providing solutions to your process and measurement problems HV Installation Testing – Ductor testing of busbar connections, isolator and circuit breaker contacts; Hipot testing between phases and phase to earth Value Add Services Data Management All inspected equipment is recorded into a live database Test results are recorded (pass or fail) Creating a history of your assets. Traceable / Track able - auditable Scheduling Scheduling service to close the circle ensuring your equipment remains within test and you compliant. We contact you (company nominated person) to schedule your next testing Flexible Service Flexible testing service designed to meet the client’s needs Eliminating your equipment downtime. Providing you the client with a more productive and efficient resource remain Factory Testing Scheduled testing can be done at equipment facilities Testing is subject to resource & equipment availability. Delivery timeframes maybe greater than scheduled testing on site Online Store To find out more about our range of products call me or visit our website www.texonsite.com.au and log on to our “Online Store” Resource & Equipment Administration Office Lilydale Victoria Locations - Melbourne, Brisbane, Perth, Mackay, Toowoomba, Townsville, Gladstone, Sydney, Darwin 30 Mobile Test vans 4 Twin-Engine aircraft 2 Hubble 100kV mobile test sets 15 Hi Pot 120kV mobile test sets 1 Phenix 130kV mobile test set 2 Hi Pot 200kV mobile Test sets 3 Megger Portable Oil test set 9 Argenton Portable Earth Test sets 12 Time Electronics 5051+ Calibration Systems 12 Time Electronics Ins-Cal 5069 Insulation Tester Calibration System 11 Time Electronics Ductor Cal- Ductor Tester and micro-Ohm metre Calibration Systems TEX Onsite first Air-mobile Test and Calibration unit. This aircraft will complement our existing mobile fleet, providing a fast and efficient means of transport, thus reducing long travel hours and driver fatigue. This aircraft will be equipped with the ability to perform both HV Testing and Instrument calibrations It will provide an efficient and affective means of servicing remote clients. Clients using this service will need to assist TEX Onsite technical staff in transporting the testing equipment to a suitable testing area. Twin engine Beech craft - Baron Summary We have a fast effective mobile testing and calibration fleet designed to meet your needs. Our main locations are Melbourne, Brisbane, Perth, Townsville, Gladstone, Sydney, Mackay, Darwin Our staff will visit your location to advise and discuss your testing requirements, ensuring your equipment is appropriately tested or calibrated and is compliant against relevant state regulatory codes. We also have established TEX Onsite companies in New Zealand and USA Australia Head Office Postal Address TEX Onsite Pty Ltd Factory 10/ 64-86 Beresford Rd Lilydale Victoria 3140 Contact Tel: 1300 785 935 +61 (03) 9735 0508 Fax: +61 (03) 97350216