Science Fair Project - Risk Management and Safety
Download
Report
Transcript Science Fair Project - Risk Management and Safety
LABORATORY
SAFETY
Lisa Bognar Phillips
[email protected]
Risk Management & Safety
631-5037
http://www.nd.edu/~riskman
Including Blood Borne Pathogens, Emergency Response, Personal Protective
Equipment and Hazardous Waste Management Training
Chemical Hazards
There are two general hazard classes that
must be evaluated when assessing the
safety of a chemical:
Physical Hazards
Health Hazards
Chemical Hazards: Physical Hazards
Compressed Gas - cylinders of compressed gas are
under intense pressure.
Corrosivity – strong acids and bases can cause visible
destruction of metals at the site of contact.
Flammability - both solid and liquid chemicals can
serve as fuel sources to support a fire.
Reactivity - many substances will react violently if
allowed contact with air, water or other chemicals.
Friction, shock, light or heat can be enough to
trigger some reactions.
Oxidizability – compounds that release oxygen as
they decompose. React with flammables
Chemical Hazards: Health Hazards
Irritants - cause reversible inflammation of skin, eyes or
nasal passages.
Sensitizers - cause allergic reaction after repeated
exposures. Individual sensitivities vary.
Carcinogens - alter DNA or cause cells with altered DNA
to multiply.
Systemic Toxins - typically target a specific organ or
system (liver, kidney, blood, nervous system,
reproductive system, etc.).
Toxins – based on dose. Anything can be poisonous.
Corrosives – cause burns to the skin, eyes, mucous
membranes and respiratory tract. HF is not like typical
mineral acids. It is extremely toxic and penetrates to the
bone. Calcium gluconate is the only antidote that should
be used on an HF burn.
Routes of Entry
Inhalation:
The
major route of entry
when working with
solvents. Great rapidity
of absorption
Routes of Entry
Absorption:
May
produce systemic poisoning.
Condition of skin determines
rate of entry. Examples:
organic lead, solvents, (xylene,
methylene chloride) organo
phosphate pesticides,
cyanides
Routes of Entry
Ingestion:
Usually
accidental or due to poor
hygiene practices
Chemical Right to Know
.
MSDS Includes the following:
Product Information
Fire and Explosion
Toxicology
Health Effects
PPE
Storage
Leaks and Spills
Waste Disposal
First Aid
)
Product Information
Finding an MSDS
Chemical manufacturers and distributors
CANNOT refuse a request for an MSDS.
There are excellent on-line MSDS databases:
http://www.hazard.com/msds/index.php
http://www.nd.edu/~riskman
University of Notre Dame
Chemical Hygiene Plan (CHP)
Contains information and procedures that
laboratory personnel can use to protect
themselves from the chemicals they work with
First place to look for answers to questions you
might have regarding chemical or laboratory
issues
Located on Risk Management and Safety
website
http://www.nd.edu/~riskman
Topics include:
- Emergency Response - Personal Protective Eq.
- Chemical compatibility -Waste Management
- Standard Operating Procedures (SOPs)
Personal Protective
Equipment
Gloves are required anytime you are handling
chemicals, biologicals and radioactive materials
Eye protection is required anytime you are handling
chemicals, biologicals and radioactive materials
Open toed shoes do not protect
your feet and ARE NOT allowed in the laboratory. (NO
FLIP FLOPS, SANDALS, etc)
Wear Eye Protection When Using:
Glassware under reduced pressure
Cryogenic materials
Glassware under elevated pressure
Explosives
Caustics, Irritants or Corrosives
Biohazards
Radioactive Materials
UV Light
Toxic Chemicals
Carcinogens
Flammable Materials
Lasers
Gloves
Be sure you
know which
type of glove is
appropriate for
the chemical
you are using
Example of wrong glove having
been used
Gloves
Remove soiled
gloves. If gloves
become soiled or
contaminated
during experiment,
stop, and remove
carefully.
Wash your hands and put on new pair of gloves.
If you double-glove, remove soiled glove, replace
with new one, and continue your work.
Safety Equipment:
Chemical Fume Hood
Airflow into the hood prevents
chemicals inside from migrating
out into your breathing zone.
If air velocity into the hood is
impeded or slowed, the hoods
ability to capture chemicals is
compromised.
Factors that affect airflow:
•Sash Height
•Drafts
•Bulky objects inside
Gas Cylinder Safety
Storage and Handling
Gas cylinders should not be stored in exits or egress routes or
blocking any safety equipment
Gas cylinders (excluding lecture bottles) should be stored in an
upright position and with safety caps in place unless in use.
Use only the appropriate regulator for the gas
Gas cylinders must be secured with a chain or appropriate belt
above the midpoint but below the shoulder of the cylinder
Cylinder Safety
What’s Wrong in this
Picture?
Cylinder must be secured by
chain or other steadying
device
Electrical Safety
Eliminate frayed or worn
wiring
Never stretch wires
across floor or other
equipment.
Staff should know
location of circuit
breakers
Electrical Safety
Match size of extension cord
to appliance power cord to
prevent cord overheating.
Extension cords are not
intended for "permanent"
installations -- appliances
shall be connected to
permanently wired
receptacles.
Examples of Poor Storage
•Never store a chemical
with a missing or obscured
label
)
Container Labels
All chemicals (including solutions
and chemicals transferred
from their original containers)
should be labeled with their
common names,
concentrations and hazards.
Additional information such
as: date received, date
opened, date of expiration
should also be recorded.
Label may also include: Proper handling,
Storage, Emergency response
Refrigerators and Freezers
Ordinary household refrigerators and
freezers constitute a hazard when used
for storage of flammable or unstable
chemicals. These units produce
conditions that can lead to explosions.
Domestic refrigerators should not be
used for flammable chemical storage.
"Lab-safe" refrigerators and freezers
(designed for storage of flammable
liquids) must be used for flammable
chemicals.
Definition
Biosafety
The application of combinations
of
laboratory practice and
procedure,
laboratory facilities,
and safety
equipment when
working with
potentially
infectious
microorganisms.
We use these practices to protect the workers and
those around, the product and the environment.
Laboratory Requirements
Knowledgeable supervisor
Knowledgeable personnel
Aware of potential hazards
Proficient in lab practices & techniques
Availability of a lab specific biosafety
manual
Contact information
Copies of IBC,IRB,RCC, and/or IACUC
protocols
Standard Operating Procedures
For unique procedures
Laboratory inspection checklist
Emergency response plan
Special procedures where needed
Relevant reference materials
Classification of
Infectious Agents
Found in the NIH Guidelines.
Classified into risk groups on the
basis of risk to the individual and to
the community.
Currently, 4 risk group levels have
been designated.
the least risk (RG-1) to the most risk
(RG-4).
RG-1 Agents
Agents
Not associated with disease in
healthy adult humans.
Generally only require a
laboratory with minimal
containment
Biosafety Level 1 laboratory
“Declaration of Dangerous
Goods” is not required for
shipment.
Bacillus subtilis, Saccharomyces cerevisiae,
Staphylococcus epidermidis, Escherichia coli
K-12
RG-2
Associated with human diseases
which are rarely serious.
Preventative and therapeutic
interventions are available.
Generally require a laboratory
with moderate containment.
Biosafety Level 2 laboratory
“Declaration of Dangerous
Goods” required for shipment.
Measles virus, Salmonella spp., Toxoplasma
spp., Hepatitis B virus, leshmainia,
plasmodium falciparum
Biohazardous Waste
Containers
Biohazardous waste
containers shall be
clearly marked with
the universal
biohazard symbol.
•Puncture-proof, leak-proof,
sealable receptacles
•avoid over-filling
Orange Biohazard Bags
Orange Biohazard Bags contain
previously contaminated waste that
has been decontaminated
(autoclaved) by lab personnel. May
be taken to the dumpster if brown
bagged. Housekeepers WILL NOT
handle these bags.
Emergency Response
Fires/accidents
911
(From a cell phone 574-631-5555)
Spills
1-5037
(Risk Management and Safety)
After Hours Spills 911
State the type of emergency and the exact
location of emergency.
If a chemical is involved spell the chemical
name to the dispatcher.
Fire Safety
•Alert persons in area of fire
•Close doors to confine fire
•Activate fire alarm
•Evacuate through nearest
exit
•Do not use elevators
•Move away from the
building.
How to Use a Fire Extinguisher
pull pin
aim at the base of the fire
squeeze handle
sweep from side to side
Fire Extinguisher Training
Learn how to operate a
portable fire extinguisher
by participating in fire
extinguisher training
program sponsored by
Notre Dame Fire
Department. Contact
them at 1-6200 if you
would like to take the
class
US&A (v 2/07)
Biological/Chemical Exposures
Needle Sticks:
Ocular Exposures:
Dermal Exposures:
•Wash thoroughly
with soap and water
•Rinse at eyewash at
least 15 minutes
•Identify source
(consent?)
•Hold eye open to
ensure effective
wash
•Rinse under drench
shower at least 15
minutes
•Remove all
contaminated clothing
•Seek Medical Treatment
•Your supervisor must fill out an accident/exposure form
First Aid - Chemical Burns (Eyes)
Forcibly open eyelids to ensure
effective washing behind eyelid
Wash from nose out to ear to avoid
washing chemicals back into eye or
into an unaffected eye
Flood eyes and eyelids with
water/eye solution for
minimum of 15 minutes
First Aid - Chemical Burns (Eyes)
Make sure you know the location of the
nearest eyewash station.
Eye Wash Maintenance
Eyewashes are periodically
checked by Maintenance but
are not flushed. Lab personnel
must test eyewashes monthly.
Designate someone to test eye
washes monthly. Let run for 1
minute
Spill Response
Be prepared for
emergencies
Biological
Spills/Decontamination
• Cover spill with paper towels
• Soak towels with disinfectant
(10% Bleach is effective)
• Wait 10 minutes
• While wearing PPE,
clean up the spill using
paper towels
Notify Risk Management
1-5037 if you need assistance • Wipe spill area with
disinfectant
• Dispose of all clean-up
materials as biological
waste (red bag)
Chemical Spills
Identify the chemical
Assess your ability to safely
contain and clean up the spill:
(spill size, chemical identification,
I CAN safely PPE)
I CANNOT safely
clean it up
Notify coworkers and
secure the area
Use spill kit to contain and clean
up the spill (MSDS helps)
Call Risk
Management to
confirm clean up
clean it up
Notify coworkers and
vacate/secure the area
Call 911
On cell call
574-631-5555
Chemical Waste Disposal
Satellite Accumulation
Container
•Compatible and in good condition
•Has “tight-fitting” closure and
container is closed unless adding
waste.
Label (3 things):
•Must be labeled as soon as first
drop of waste is put into the
container.
•Words “waste or “hazardous
waste”
•Description or Name of
chemical(s)
Secondary Containment
•Must segregate incompatibles
•One container per waste stream
Hazardous Waste Disposal Rules
Do not use chemical
symbols or
abbreviations when
labeling your
containers
US&A (v 2/07)
341
Chemistry
Acetone
20
Methanol
40
4 Liters
Generator Signs
Faculty name printed
RM&S use
ONLY
Abbreviations and
formulas NOT acceptable
Person who generates
waste signs form
All other waste…
Gloves, paper, etc:
disposed of in regular (clear) trash
bags and bags are to be removed by
custodians daily.
Broken Glass: if clean, should be
disposed of in a puncture proof box
marked “Broken Glass”.
Laboratory Security
There are extremists who vandalize workplaces where they
suspect animal research is being conducted and others who
identify sources for chemicals/ biologicals to be used in
terrorism or illegal drug production
Protect your lab and your research:
• NEVER prop open any card or key
access corridor doors.
•Don’t let people ‘piggy-back’ to gain
access to restricted areas.
• Keep your lab doors closed and
locked when unattended.
•Question strangers, and report
suspicious activity to campus security.
Emergency Phone Numbers
• Security
911 or 631- 5555 from cell
• Risk Management & Safety 1-5037
• ND Fire
1-6200