Treatment of Drill Cuttings from Decommissioned Oil Rigs

Download Report

Transcript Treatment of Drill Cuttings from Decommissioned Oil Rigs

RECOVERY OF RESIDUAL OIL FROM
RAPE/SUNFLOWER MEAL





Introduction
Principles of Technology
Application to Oil Recovery
Plant Details
Contact Details
Confidential
2



Rotawave Ltd is part of the Energy Environmental Group
of Companies
The Rotawave Microwave process is manufactured inhouse at our new factory on the Isle of Wight and at our
facility in Queensferry, Chester.
The group employees over 70 people
Energy
Environmental
Ltd
Rotawave Ltd
Vikoma
International Ltd
Screw Conveyor
Ltd
Confidential
3

1. Microwaves & 2. Ceramics
Microwaves
High Penetration
Water / Oil
+ OHMIC HEATING
No contact
Selective hence
Low Bulk
Temperature
Rupture Cells
Meal
Non Stick Ceramic
lifts material away
from zero field
No fouling
Confidential
4

3. Infra Red, 4. Louvers, 5. Vacuum
Oil & Water
Rapid Evaporation
from Surface drives
diffusion
Infra Red
High Energy
Low Penetration
Confidential
5
START
ROTAWAVE
FINAL
PRESS
CAKE
RAW OIL
+ WATER
Final PressCake:-Less than
1% oil remaining
Confidential
6




Independent Gas
Chromatogram for
recovered oil
Recovered Oil has not
been thermally degraded
Low ash
No PAHs, PCBs
C12
C11
C13
C14
C15
C16
C17
C18
Halliburton Presentation
7
•
•
•
•
Equipment delivered
on 3 flat bed trucks
Equipment mobilised
and installed on site
in 10 days
Operated in a small
space
Operated within site
dust restrictions and
Noise limits
Confidential
8







Assumptions based on 5 tonne/hr machine
processing 36,000 tonnes per annum.
Feed Material is Meal with 18% Oil, 5% water
Operating Cost to extract Oil: 21 €/Te (feed)
Income from recovered Oil:
36 €/Te (feed)
Profit
15 €/Te (feed)
Profit per annum
540,000 €/p.a.
Capital Cost
1,500,000 €
Confidential
9






Employs highly efficient electromagnetic heating methods –
minimising energy usage
Treating meal with non-contact microwaves and rupturing cells
to maximum oil yield
Microwave allows high internal temperatures but LOW bulk
temperatures
Providing a very flexible and controllable continuous thermal
process – electromagnetic energy is instantly responsive to the
control system – no thermal degradation of oil
Occupies a very small foot print – the central processor is
smaller than a 40 foot container
Low operating cost with less than 3 year capital payback
Confidential
10







Mr. Garth P. W. Way B.Eng(Hons) MIChemE
12 Bon-Accord Square , Aberdeen, AB11 6DJ
Telephone 
+44 (0)1224 590866
Fax 
+44 (0)1224 577945
Mobile 
+44 (0)7949 206 315
: [email protected]
Skype: garth.way1
Confidential
11