Application Notes for Line Testing with ET 91
Single Sided Measurements
END to END Measurements
LCL Balance
Impedance
Return Loss
Near End Crosstalk
Spectrum Analyser
Frequency Response with MTTS
Automatic Master Slave Test
Micro Interruption Analysis
To learn more click on note!
ELEKTR
NIKA
LCL Balance Measurement with ET 91
Two balance measuring modes are provided:
■ Measurement with one single frequency
■ Measurement in sweep mode
ET 91 performs LCL measurement using the test circuit described in ITU-T Rec. 0.9
Selectable ranges
Test results are available in graphic or numeric formats.
ELEKTR
NIKA
Impedance Measurement with ET 91
ET 91 provides impedance measurement for balanced and coaxial test
objects in fix frequency or sweep modes without any external adapter.
Selectable ranges
Test results are available in graphic or numeric formats.
ELEKTR
NIKA
Return Loss Measurement with ET 91
ET 91 provides return loss measurement for balanced and coaxial test
objects in fix frequency or sweep modes without any external adapter.
Selectable ranges
Test results are available in graphic or numeric formats.
ELEKTR
NIKA
Near End Crosstalk measurement with ET 91
ET 91 provides Near End Crosstalk measurement for balanced and
coaxial test objects by transmitting on socket L2 and receiving on L1.
Fix frequency or sweep modes are available
Selectable ranges
Test results are available in graphic or numeric formats.
ELEKTR
NIKA
Spectrum Analyzer Measurement with ET 91
ET 91 provides sophisticated spectrum analyser measurements
with extremely large dynamic range and high resolution.
Display range: down to -140 dBm/Hz
Evaluation: NORM, PEAK, AVG, SAWG
Power Spectral Density (PSD) Measurement
Noise Level Measurement
Selectable ranges
Test results are available in graphic or numeric formats.
ELEKTR
NIKA
Quick Frequency Response Test of ET 91 with
Multi Tone Test Signal
Selectable ranges
MTTS METHOD:
ADVANTAGES:
■ The transmitter generates 35 test tones
■ The receiver measures the 35 test tones simultaneously
■ No synchronisation is necessary between the two instruments
■ The measuring time is shorter than that of other methods
ELEKTR
NIKA
Automatic Line Test in Master Slave Mode of ET 91
▼
Click here to see
detailed results
ELEKTR
NIKA
Detailed Test Results of Automatic Master Slave
Line Measurement
All the test results are available also in numeric form
and they can be transferred to PC via USB interface.
ELEKTR
NIKA
Micro Interruption Measurement with ET 91
An interruption is detected when the level of test tone drops below a designated threshold for
more than 0,6 ms. The detected interruptions are included into five categories by duration
▼
Click here to see detailed results
in numeric and graphic forms
ELEKTR
NIKA
Detailed Results of Micro Interruption Measurement
All the test results are available also in numeric form
and they can be transferred to PC via USB interface.