1. dia - Elektronika

Download Report

Transcript 1. dia - Elektronika

Application Notes for Frequency Division Multiplex System Testing with ET 91 Basic, Super & Master Group

Level Measurement in Tracking Mode

Noise Level Measurement

Pilot Level Measurement

Voice Frequency Noise

Psophometric Noise Measurement

Impulsive Noise Measurement

END to END Measurements

Automatic Master Slave Channel Test

Frequency Response Test with MTTS

Micro Interruption Analysis

Group Delay Distortion

Jitter and Frequency Difference

To learn more click on note!

ELEKTR NIKA

Signal Level Measurement in Transmitter Tracking Mode of ET 91

ELEKTR NIKA

Changing the transmitter frequency ( Tx ) the receiver automatically follows the change according to the selected rule: Rx =CARRIER+Tx or CARRIER-Tx

Noise Level Measurement at Master Group with ET 91

ELEKTR NIKA

Pilot Level Measurement at Super Group with

ET 91

ELEKTR NIKA

Pilot Frequency Allocation Schematics

ELEKTR NIKA

Psophometric Noise Level Measurement with ET 91 Display format up to 1 min Display format over 1 min

ELEKTR NIKA

Impulsive Noise Measurement with ET 91 Display format up to 30 sec Display format over 30 sec An impulse is counted when the received noise signal exceeds a preset threshold for more than 500 ns

ELEKTR NIKA

Automatic Channel Test in Master Slave Mode of ET 91

▼ Click here to see detailed results

ELEKTR NIKA

Test Result of Automatic Tone Channel Test All the test results are available also in numeric format and they can be transferred to PC via USB interface .

ELEKTR NIKA

Frequency Response Test of ET 91 with MTTS Method MTTS METHOD: The transmitter ■ generates 36 test tones ■ Frequency range: 100 to 3600 Hz Frequency step: 100 Hz ■ Level: -20 dBm / frequency The receiver measures the 36 test tones simultaneously ADVANTAGES: ■ No synchronisation is necessary between the two instruments ■ The measuring time is shorter than that of other methods

ELEKTR NIKA

Micro Interruption Analysis with ET 91 An interruption is detected when the level of test tone drops below a designated threshold for more than 0,6 ms. The detected interruptions are included into five categories by duration

▼ Click here to see the test results In graphic and numeric forms

ELEKTR NIKA

Detailed Results of Micro Interruption Analysis All the test results are available also in numeric form and they can be transferred to PC via USB interface .

ELEKTR NIKA

Group Delay Distortion Measurement with ET 91 ET 91 applies the multi tone test method described in Recommendation ITU-T O.81 Appendix I The transmitter ■ generates 36 test tones ■ Frequency range: 100 to 3600 Hz Frequency step: 100 Hz ■ Level: -20 dBm / frequency The receiver measures the 36 test tones simultaneously

ELEKTR NIKA

Phase Jitter and Frequency Difference Measurement ET 91 performs jitter and frequency error measurements simultaneously according to Recommendation ITU-T O.91

That measurement needs two instruments connected to the ends of the tested line.

■ One of them transmits jitter free quartz accurate 1020 Hz test tone ■ The other one receives and evaluates it

ELEKTR NIKA

THANK YOU FOR YOUR ATTENTION!