Fiber Optic Communications - New Mexico State University

Download Report

Transcript Fiber Optic Communications - New Mexico State University

Fiber-Optic Communications
James N. Downing
Chapter 4
Fiber and Cable Fabrication
4.1 Optical Fiber Fabrication
• Fused Silica Glass
– Medium of choice for fiber communications
– Uses a silica soot that reacts with SiCl4 and
produces GeO2. The GeO2 and P2O5 increase
the refractive index.
– The preform is a single, glass rod of about 1m
by 2cm with the refractive index of the finished
fiber.
4.1 Optical Fiber Fabrication
• Deposition Preform Methods
– Rod-in-tube
• A tube with a higher index is inserted into a lower index
tube and the two are melted to make the preform.
• Attenuation: 500 to 1000dB/km.
– Double crucible method
• Core and clad fibers are heated and pulled through
nested platinum crucibles that are narrowed to fiber size.
• Attenuation: 5 to 20dB/km
4.1 Optical Fiber Fabrication
• Deposition Preform Methods
– Inside Vapor Deposition (IVD)
• Deposits silica soot on inside wall of fused tube and then
heated
– Modified Chemical Vapor Deposition (MCVD)
• SiCl4 and SiO2 are heated to 18000C, leaving a soot on
the inside of the tube
• Attenuation: 3dB/km at 85nm
4.1 Optical Fiber Fabrication
• Deposition Preform Methods
– Plasma Chemical Vapor Deposition
(PCVD)
• Similar to MCVD except heat source is ionized
electric charge instead of gas burner
• More precise layering and refractive index
profiling
• Attenuation: 4dB/km at 850nm
4.1 Optical Fiber Fabrication
• Deposition Preform Methods
– Outside Vapor Deposition (OVD)
• Flame hydrolysis causes soot to be deposited
on the outside of the rod. The rod is then
removed and the resulting tube is collapsed to
make the preform.
• Attenuation: 1 to 2dB/km
4.1 Optical Fiber Fabrication
• Deposition Preform Methods
– Axial Vapor Deposition (AVD)
• Similar to OVD
• Rod is drawn through soot trail several times to
make the differing layers
• Attenuation: 1 to 2dB/km
4.1 Optical Fiber Fabrication
• Fiber Drawing and Coating
– The fiber can be “drawn” by heating the preform to
20000C and pulling the melting glass away from
the preform at speed of about 1m/sec.
– The fiber is coated by dipping, spraying, or
electrostatic methods.
4.2 Fiber Cable
• Fiber Cabling Considerations
– Provide protection for ease of handling
– Must withstand extremes of environment,
installation forces, and stresses
4.2 Fiber Cable
• Fiber Cable Construction
–
–
–
–
–
Buffer jacket around the fiber
Strength member provides mechanical support
Outer jacket provides protection from abrasion
Loose buffer to shield against environment issues
Tight buffer directly on the fiber
4.2 Fiber Cable
• Types of Cables
– By installation
•
•
•
•
Simplex: one-way communication
Duplex: two-way communication
Multifiber: many fiber pairs in bundle
Ribbon: fibers in a row
4.2 Fiber Cable
• Types of Cables
– By applications
•
•
•
•
•
•
Light duty
Heavy duty
Plenum: between walls
Riser: between floors
Indoor
Outdoor
4.3 Connectors
• Connector Considerations
– Tolerances are stringent
– Precision alignment
• Fiber and Cable Preparation
– Ends must be smooth and clean
• Cleaving: good enough for splices
• Polishing: for all connectors
4.3 Connectors
• Connector Installation
–
–
–
–
Depends on the connector and application
Flat finish: Used for multimode applications
Domed PC finish: Provides for good core contact
APC finish: Polished at 80 angle for matching
purposes
4.3 Connectors
• Types of Connectors
– Major Categories
• Standard
• Small
– Sub Categories
• Ferrule
• Connection method
• Number of fibers
4.3 Connectors
• Standard Connectors: 2.5mm ceramic ferrule
– FC: Earliest design with threaded coupling and
adjustable keying to minimize loss
– SC: Rectangular snap-in-plug in which the
housing is not directly attached to the cable
– ST: Evolved from copper connectors and the most
popular; similar to FC but with quick connects and
bayonet coupling and ½ turn keying
4.3 Connectors
• Standard Connectors
– FDDI: Two 2.5 mm ferrules stacked together
– ESCON: IBM fiber optic based channel control
– SFF:
• MT: 12 single or multimode fibers
• LC: doubles the count of standard connectors in same
area. Used with RJ-45.
• VF-45: contains a fiber holder, hinged door, and V-groove
for alignment purposes
4.4 Connector Losses
• Intrinsic Loss
– Caused by mismatches in
• Numerical aperture
• Core diameter
• Core area
• Extrinsic Loss
– Caused by differences in connectors which cause
misalignment
4.4 Connector Losses
• Insertion Loss
– The attenuation of any connector or component
inserted inline
– Used for power budget calculations
4.5 Splices
• Mechanical
– Can be installed in the field with minimum tools
– Losses: 0.3db
• Fusion
– Junction must be heated
– Special tools
– Losses: 0.1dB
4.5 Splices
• Applications
– Splice Tray: Secures a long row of splices and
prevents them from moving inside the closure
– Splice Panel: Provides sealed protection for splice
trays
– Splice closure: Used in aerial and underground
telephone cable runs