Transcript Slide 1
How FDT Technology Interfaces with Major Fieldbus Networks Geoff Wickens FDT Group Fieldbus technology is rapidly being adopted in the process industry… Fieldbus provides: o Improved plant efficiency, safety and productivity o Access to asset health through digital communications Asset management is an essential components of any successful process automation strategy ISA 2008 Jason Norris 2 FDT technology has freed end user’s from vendor proprietary solutions Choose the best in class Instrumentation Device configuration software Asset management tools ..And no more vendor specific software FDT connects with 12 different protocols AS-interface INTERBUS ContolNet IO Link DeviceNet MODBUS SL/TCP EtherNet/IP PROFIBUS DP/PA FOUNDATION Fieldbus HART PROFINET I/O CIP Annex configuration The DTM… …is the driver representing the actual device …is provided by the device manufacturer … is loaded on any Frame Application …has a standardized interface to the Frame Application …has the graphical user interface …includes the complete parameters of the device Device Type Manager Communication independence FDT supports all communication protocols for Factory and Process Automation FDT fits all physical networks FDT - How does it work? One FDT interface to the Frame Application (DCS, PLC, Asset Management, Engineering Tool) and to the DTM One DTM per device fits into all Frame Applications One Frame Application accepts all DTMs FieldCare PACTware Asset Mgmt. System/ Engineering Tool DCS DTM DTM PLC DTM DCS PLC Configuration Parameterization Start Up DTM Alarm Model Monitoring Plant Diagnosis Calibration Maintenance DTM DTM Networked communication FDT maps existing networks A) Simple networks Ethernet TCP/IP CommDTM Device DTM HART FDT provides detailed information Getting more out of the devices you already have! FDT makes life easier Device operation via DTM with graphical user interfaces and dialogues Pictures are worth a 1000 words 17.07.2015, Event Your name 12 17.07.2015, Event Your name 13 Tested combinations CS 3000 ND 9000 Delta V IACC DD Yes Yes Yes eEDDL No Yes Yes DTM Yes No Yes DD Yes Yes Yes eEDDL No Yes Yes DD Yes Yes Yes DTM Yes No Yes DD Yes Yes Yes DTM Yes No Yes Field Mate PACT Ware Field Care Yes Yes Yes Yes Yes Yes Yes Yes Yes DVC 6000 SRD 991 EJX MV The FF Devices available with DTM & eEDDL were limited! The DTMs provided had not passed the dtmINSPECTOR Test (yet)! 14 Evaluation Result DD (Example) Multiple tabs List of parameters Look and feel is same within a single DCS system, but is very different per DCS No user friendly parameterization No graphics DDs must contain the minimum data required at the Operator’s Station! 15 Evaluation Result eEDDL (Example) Predefined set of graphics but not the same on different DCS No data storage No intelligent wizards There is no standard EDDL to provide common GUI for all similar devices in different DCS! 16 Evaluation Result eEDDL (Diagnosis) Online device diagnostics defined by DCS vendors EDDL allows DCS to define how device appears and what it can do! 17 Evaluation Result DTM (Diagnosis) Automatic presentation of diagnostic alerts Look and feel of DTM is same in all DCSs and all Frame applications for each vendor DTMs are based on FDT/DTM Guidelines used by all developers! 18 Evaluation Result DTM (Example) Full graphical support No loss of results during open/closing of different DTM screens Data storage Configuration and test results in one view DTMs have additional capability to store data for baseline & trending! 19 WIB project: Conclusions (1) Basic claims on pros/cons of FDT/DTM and eEDDL are confirmed using FF technology. Basic DDL Enhanced DDL FDT FF block configuration Yes Yes Yes (1) Calibration Methods No Yes Yes Device Setup Wizards No Limited Yes Very limited Limited Yes State of the art GUI No Very limited Yes Data storage and reporting functionality No Limited Yes Capable of any type of complex calculations No Limited Yes Advanced diagnostics for sophisticated devices No Limited Yes FUNCTION Programming flexibility 1 –for safety and operations a standard guide is needed to limit who can change the device configuration. DTM provides the most functionality for a Device! 20 WIB project: Conclusions (2) There are not sufficient FF devices with DTM or eEDDL in the market. eEDDL offers required data accessibility and functionality as used in commissioning of FF smart devices. FDT/DTM offers enhanced data accessibility and extended functionality as used in commissioning and maintenance of FF smart devices in a very effective and flexible manner. 21 WIB project: Recommendations Systems should support both eEDDL and FDT/DTM. More FF devices with eEDDLs and DTMs are required. Certification for (FDT) Frame applications is needed. DTMs already have dtmINSPECTOR 2.0 for certification. Add a hierarchal order to for FF Function Block, Device Configuration Change Management (DCCM) and standard menu system to the FDT/DTM Style guide. Vendors should provide DTMs for their FF devices and include more device intelligence in their DTM solutions. 22 WIB test summary The independent WIB test confirms that there is a real need for FDT Technology: FDT delivers new and extended capabilities – as promised eEDDL is limited to data access, parameterization and commissioning FDT is the right platform for applications in configuration, operation and maintenance WIB encourages vendors to provide DTMs for all of their devices 23 Conclusion FDT Technology delivers value FDT is increasingly accepted by the market recommended and specified by leading end users getting more visibility in the media getting recognition by the industrial automation community FDT is receiving increasing acceptance from Device manufacturers and DCS Providers FDT’s open architecture provides a level playing field which benefits the end users, DCS providers and device manufacturers FDT IS THE RIGHT TECHNOLOGY! 24 Overview FDT Technology designed for Plant Lifecycle Management Engineering/ Configuration User Interface Functionality Graphical support Device specific algorithms and functionalities Commissioning Operation Integrated specific procedures for parameterization, calibration, and complete commissioning Maintenance/ Diagnostics Provides intuitive user interfaces for online information viewing and data access Provides procedures for predictive maintenance and advanced diagnostics Data validation and compare DD with enhanced visualization and user interface (HMI) Developed for device configuration & methods Proprietary DD add-on DD FDT, EDDL and FDI, EDD Plant Lifecycle Your name Proprietary EDD add-on DTM 25 Members Open access to device intelligence www.fdtgroup.org 17.07.2015, Event Your name [email protected] 27