DCN Accessories and Installation equipment

Download Report

Transcript DCN Accessories and Installation equipment

Security Systems BU Communication Systems
Trunk Extension Cables

LBB4116/xx
Cable without connectors
• LBB 4116/00 100 m (328.0 ft) length

Cable with connectors
• LBB 4116/02 2 m (6.6 ft)
• LBB 4116/05
length
5 m (16.0 ft) length
• LBB 4116/10 10 m (33.0 ft) length
• LBB 4116/15 15 m (49.2 ft) length
• LBB 4116/20 20 m (66.0 ft) length
• LBB 4116/25 25 m (82.0 ft) length

Set of 25 cable clamps
LBB 4117/00
30.11.2004
DCN SA PO AIE
I&O Manual
ST/SEU-CO 1
Security Systems BU Communication Systems
Extension Cable wiring
LBB4116/xx
PIN 1 - Down- link screen (ground)
PIN 2 - Down- link signal data from CCU (green)
PIN 3 - Positive supply (max. 40V) (brown)
PIN 4 - Up- link- signal data to CCU (white)
PIN 5 - Up- link screen (ground)
PIN 6 - Positive supply (max. 40V) (blue)
30.11.2004
DCN SA PO AIE
I&O Manual
ST/SEU-CO 2
Security Systems BU Communication Systems
Trunk Cable Splitter Unit
1
tap-off 1 3
LBB 4114/0x
2
4 tap-off 2

1 DCN cable
A 2 m long cable to connect the trunk cable splitter
to the system with a, male, 6-pole, circular connector.

2 DCN socket (trunk)
A female, 6-pole, circular socket to loop the trunk
cable splitter through in the system.

3 DCN socket (tap-off 1) A female, 6-pole, circular socket to create a tap-off.
The signal is automatically regenerated.

4 DCN socket (tap-off 2) A female, 6-pole, circular socket to create a tap-off.
The signal is automatically regenerated.
Note:
it’s never allowed to put trunk cables in parallel you always have to use a
Cable Trunk Splitter or Tap-Off unit.
30.11.2004
DCN SA PO AIE
I&O Manual
ST/SEU-CO 3
Security Systems BU Communication Systems
Trunk Cable Splitter Unit
30.11.2004
DCN SA PO AIE
LBB 4114/0x
ST/SEU-CO 4
Security Systems BU Communication Systems
Tap-Off Unit Limitations
30.11.2004
DCN SA PO AIE
LBB 3515/0x
ST/SEU-CO 5
Security Systems BU Communication Systems
Tap-Off Unit Limitations
LBB 3515/0x
The LBB 3515/ 00 is used to create short- circuit proof tap- off points on the trunk- line
cabling. Each tap- off point allows for connection of up to five channel selector panels
or one contribution unit such as delegate, chairman or interpreter unit. The tap- off unit
comes complete with cable restraining clamps and includes mounting holes for fixing
purposes.
Interconnection
1. 2 m (6.5 ft.) long cable terminated with a moulded 6- pole circular connector.
2. 6 pole circular connector for tap- off purposes. The tap- off is equipped with an
electronic short circuit protection facility on the power supply lines with a max load
of 2.5 PCF.
3. 6- pole circular connector for loop- through connections (Trunk).
4. 6 pole circular connector for tap- off purposes. The tap- off is equipped with an
electronic short circuit protection facility on the power supply lines with a max load of
2.5 PCF.
5. Screw holes for securing the unit.
30.11.2004
DCN SA PO AIE
ST/SEU-CO 6
Security Systems BU Communication Systems
Data Distribution Board
30.11.2004
DCN SA PO AIE
LBB 3512/00
ST/SEU-CO 7
Security Systems BU Communication Systems
Data Distribution Board
LBB 3512/00
Connectors, Controls and Indicators
1. 6 x 3.5 mm (0.13 in) mounting holes.
2. 2 x jumpers to select between either the DCN system power supply or an
external power supply.
3. 9- pole Sub-D connector (male) for RS232 communication.
4. 4 x LED indicators for test purposes.
5. Parallel input connector 20-pole Micro-Match connector.
6. Parallel input contacts via 20 solder pads.
7. Connector for test purposes.
8. 8- pole dip switch for communication mode and function setting, see I/O
Manual.
9. Parallel output contacts via 20 solder pads (open collector outputs).
10. Initialisation button with LED indicator to indicate the none initialised mode.
11. Parallel output connector 20-pole Micro-Match connector.
12. 10-pole Micro-Match connector for the external power supply.
13. 2-pole external power supply connector (2-solder pads) and a 2-pole screw
connector.
14. 2 m (6.5 ft) long cable terminated with a 6-pole circular connector for
connection to the DCN trunk-line.
30.11.2004
DCN SA PO AIE
ST/SEU-CO 8
Security Systems BU Communication Systems
Numeric Hall Display with
Data Distribution Board
Voting timer
Nevertheless the
"voting time" is
given by DCN but
only with PC-control
Address
248
30.11.2004
DCN SA PO AIE
ST/SEU-CO 9
Security Systems BU Communication Systems
Connecting Hall Displays to DCN System
30.11.2004
DCN SA PO AIE
ST/SEU-CO 10
Security Systems BU Communication Systems
Applications with Data Distribution Board
30.11.2004
DCN SA PO AIE
ST/SEU-CO 11
Security Systems BU Communication Systems
Analog Audio Input/Output Module LBB 3513/00




30.11.2004
DCN SA PO AIE
For interfacing with external
analogue audio / music signals
Can be used for remote
interpretation
Needs DCN SW 8.10 or higher
Audio input = interpretation
channels only
IFU Manual
ST/SEU-CO 12
Security Systems BU Communication Systems
Analog Audio I/O Module
30.11.2004
DCN SA PO AIE
LBB3513/00
ST/SEU-CO 13
Security Systems BU Communication Systems
Controls and Indicators AIO Module
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
30.11.2004
Limiter ON/OFF switch (selection of correct max. channel signal level input)
Limiter ON/OFF LED (yellow)
Rotary switch (audio output channel selection 0 -15) (distribution)
Assigned LED (red) Module active at selected audio down-link channel (output)
Rotary switch (audio input channel selection 0 -15) (contribution)
Assigned LED (red) Module active at selected audio up-link channel (input)
Engaged LED (yellow) Selected audio up-link channel engaged
Error indication LED (red) (indicates fault situation)
Remote control LED (yellow) (Off - local control, On - Remote control)
Initialisation LED (red) (Off module initialized, On module not initialized)
Power ON LED (green)
Module Initialization/De-initialization switch (Init/de-init)
25-pole connector for ribbon cable of remote connector
Location for optional input transformer type Beyer TR/BV3
3-pole XLR INPUT connection (female)
3-pole XLR OUTPUT connection (male)
6-pole DIN connector (female) for loop-through to other DCN system units.
6-pole DIN connector (male)
Solder connections 6-pole DIN connector
DCN SA PO AIE
ST/SEU-CO 14
Security Systems BU Communication Systems
Analog Audio In and Outputs
30.11.2004
DCN SA PO AIE
ST/SEU-CO 15
Security Systems BU Communication Systems
Remote Controls and Indicators AIO
NOTE:
According the diagram, when
connecting remote selectors
for input and output channel
selection and limiter switch,
the on-board switches are
disabled. However, both the
on-board LEDs and the
remote panel LEDs will be
active.
30.11.2004
DCN SA PO AIE
ST/SEU-CO 16
Security Systems BU Communication Systems
Electrical data and requirements
- Supply voltage
: 17 - 40 V
- Current consumption (approx.)
: 40 mA at 40 V, 50 mA at 17 V
- Audio input impedance (symmetrical)
: >10 kOhm (no transformer)
- Audio input attenuation (blocked)
: >80 dB at 1 kHz
- Nominal audio input level (limiter off)
: -3dBV
- Nominal audio input level (limiter on)
: -24 dBV
- Maximum audio input level
: 6 dBV
- Audio output impedance (symmetrical)
: <600 Ohm at 1 kHz
- Audio output attenuation (blocked)
: > 80 dB at 1 kHz
- Nominal audio output level (-9 dBFS)
: 1 dBV
- Maximum audio output level (0 dBFS)
: 10 dBV (22 dBV for PA-channel)
- Maximum cable length for remote control : 25 m
- Current consumption for LEDs connected
to the Remote control
: 5 mA
- Frequency response
: equal to transmission link freq.
response of DCN system
30.11.2004
DCN SA PO AIE
ST/SEU-CO 17
Security Systems BU Communication Systems
19” Rack, rear mounting
30.11.2004
DCN SA PO AIE
ST/SEU-CO 18
Security Systems BU Communication Systems
Applications





30.11.2004
Recording languages (one by Module)
Remote Interpretation using telephone couplers
Remote Interpretation using Video conferencing equipment
Music distribution
Sharing languages between DCN systems
DCN SA PO AIE
ST/SEU-CO 19
Security Systems BU Communication Systems
Remote Interpretation


Communication, - POTS or ISDN line 722 or layer 3
Telephone coupler -Telos type One or Zephyr
Note: LBD 4503/xx can not be used
30.11.2004
DCN SA PO AIE
ST/SEU-CO 20
Security Systems BU Communication Systems
Remote Interpretation for Video conferencing
Audio and image of the delegate speaking
30.11.2004
DCN SA PO AIE
ST/SEU-CO 21
Security Systems BU Communication Systems
Music Distribution of external music sources
Distribution
30.11.2004
DCN SA PO AIE
ST/SEU-CO 22
Security Systems BU Communication Systems
Sharing languages between DCN systems
Distribution part
Contribution
30.11.2004
DCN SA PO AIE
ST/SEU-CO 23
Security Systems BU Communication Systems
Telephone Coupler
30.11.2004
DCN SA PO AIE
LBD 4503/03
ST/SEU-CO 24
Security Systems BU Communication Systems
Telephone Coupler Telos
Telos ONE Digital Hybrid Telephone Interfaces
30.11.2004
DCN SA PO AIE
ST/SEU-CO 25
Security Systems BU Communication Systems
Accessories and Installation Equipment
End of section
 Robert Bosch GmbH
All rights are reserved. Reproduction or passing on to
third parties in whole or in parts is prohibited without the
written consent of the copyright owner.
30.11.2004
DCN SA PO AIE
ST/SEU-CO 26