Transcript Document

Fault Tolerant Configuration
Host System and FT |
JAN 2 0 1 3
Fault Tolerant System Architecture
• Host System Software
– LiNC-NXG, LiNC-Plus, LiNC-XS, EBI*
• Fault Tolerant Architecture
– FTC Controllers
– Door Modules
• Dual Door Module (DDM)
– Single Door Module (SDM)
• Ethernet Communication
• Up to 3 Communication Ports
– Ethernet
– PoE
– XBee PRO DigiMesh
Controller Components
• Fault Tolerant Controller (FTC)
– Distributed Intelligent Controllers with Hydra
• Door Modules
– DDM series (Dual Door Module)
• Any Reader or Biometric Type
• Supervised Reader Detect
– SDM (Single Door Module)
• Single Door controller (No reader)
– SDM ER series
• All inclusive (Multi-Tech Reader and Controller)
Basic Fault Tolerant Archtecture
Ethernet Network
FT Configuration – “CLIQUE”
• A Clique is a “group” of Fault Tolerant
Controllers and Door Modules
– Maximum 8 – Fault Tolerant Controllers
– Maximum 112 – Door Modules (DDM/SDM)
• Up to 224 readers
• A Clique Communicates Information within
itself and to the Host
• No limit to the number of Cliques per
system
Design Recommendations
• Fault Tolerant Controller Capabilities
– Monitor and Control up to 16 DDM or SDM
• Clique Size
– Up to 8 FTC
– Total 112 door control modules
• Up to 224 readers if all controllers are DDM
Typical Enterprise Network Application
Clique 2
Clique 1
Clique 4
Clique 3
Clique "n"
Basic Door Architecture
Motion Detector
Ethernet
Battery Output
DDM
Fingerprint Reader
with RFID Reader
RFID Reader
with Keypad
Reader Cable Requirements to the Door:
6 conductor, 22 AWG, Stranded with overall Shield.
Fingerprint Reader will require its own power cable
(2 conductor, 18 AWG, stranded).
Door Installation Configuration A
Door Status
REX
Button
Card
Reader
Door
Strike
Non Secured Side
Secured Area
Door Installation Configuration B
PIR
(REX)
Magnetic Door Lock
Door Status
Card
Reader
Door Strike
Non Secured Side
Secured Area
Door Installation Configuration C
Door Status
Card
Reader
Card
Reader
Door
Strike
Non Secured Side
Secured Area
Typical DDM Cable Connections
REX
2 Conductor 18 AWG
Stranded
DDM
6 Conductor 22 AWG, Stranded
2 Conductor 22 AWG
Stranded
Reader
CAT 5 or 6 Cable
Door Lock
To Network Switch
Door Connections for ALL PCSC Products
Wiegand Reader Connection
Door
Connections
Door Status
Door Lock
N.O.
N.C.
Common
REX
Single Door Module (SDM)
SDM ERP40
Single Door Module Configurations
• SDM
– Single Door Controller
– PoE Communication
– Any Wiegand Card Technology or Biometric
Reader
– Door Status, REX, Door Lock Output
• SDM “ER” series
– Same as Above
– Incorporated Reader
• Proximity
• Multi-Technology
Single Cable Installation—SDM ER Series
Controller
• Ethernet or PoE
• Door Lock Output
• Door Sense Input
• Request to Exit (REX)
• Power Input
Reader - Incorporated
• Proximity
• Multiclass
Single Cable Application—SDM ERP
Door Status
Door Lock
SDM
To PoE Switch
SDM—Controller ONLY
Door Status
SDM
Lock
Reader
To PoE Switch
Multi-Tenant Application
Legacy System Upgrade Requirements
• Latest System Software
– LiNC-NXG, LiNC-Plus, LiNC-XS, EBI
• Supported Legacy Controllers
– IQ, SIM, ULT series controllers
• Upgrade Controller Communications
– LANU
– Terminal Servers
Fault Tolerance Architecture
with Legacy Controllers
Application Solutions with Fault Tolerant
•
•
•
•
•
•
•
•
•
Commercial High Rise
Enterprise Systems
Remote Managed Access
Campus Environment
Industrial
Banking
Government, HSPD compliant Cards
High Reliability
High Security Requirements