Transcript Document
Fault Tolerant Configuration Host System and FT | JAN 2 0 1 3 Fault Tolerant System Architecture • Host System Software – LiNC-NXG, LiNC-Plus, LiNC-XS, EBI* • Fault Tolerant Architecture – FTC Controllers – Door Modules • Dual Door Module (DDM) – Single Door Module (SDM) • Ethernet Communication • Up to 3 Communication Ports – Ethernet – PoE – XBee PRO DigiMesh Controller Components • Fault Tolerant Controller (FTC) – Distributed Intelligent Controllers with Hydra • Door Modules – DDM series (Dual Door Module) • Any Reader or Biometric Type • Supervised Reader Detect – SDM (Single Door Module) • Single Door controller (No reader) – SDM ER series • All inclusive (Multi-Tech Reader and Controller) Basic Fault Tolerant Archtecture Ethernet Network FT Configuration – “CLIQUE” • A Clique is a “group” of Fault Tolerant Controllers and Door Modules – Maximum 8 – Fault Tolerant Controllers – Maximum 112 – Door Modules (DDM/SDM) • Up to 224 readers • A Clique Communicates Information within itself and to the Host • No limit to the number of Cliques per system Design Recommendations • Fault Tolerant Controller Capabilities – Monitor and Control up to 16 DDM or SDM • Clique Size – Up to 8 FTC – Total 112 door control modules • Up to 224 readers if all controllers are DDM Typical Enterprise Network Application Clique 2 Clique 1 Clique 4 Clique 3 Clique "n" Basic Door Architecture Motion Detector Ethernet Battery Output DDM Fingerprint Reader with RFID Reader RFID Reader with Keypad Reader Cable Requirements to the Door: 6 conductor, 22 AWG, Stranded with overall Shield. Fingerprint Reader will require its own power cable (2 conductor, 18 AWG, stranded). Door Installation Configuration A Door Status REX Button Card Reader Door Strike Non Secured Side Secured Area Door Installation Configuration B PIR (REX) Magnetic Door Lock Door Status Card Reader Door Strike Non Secured Side Secured Area Door Installation Configuration C Door Status Card Reader Card Reader Door Strike Non Secured Side Secured Area Typical DDM Cable Connections REX 2 Conductor 18 AWG Stranded DDM 6 Conductor 22 AWG, Stranded 2 Conductor 22 AWG Stranded Reader CAT 5 or 6 Cable Door Lock To Network Switch Door Connections for ALL PCSC Products Wiegand Reader Connection Door Connections Door Status Door Lock N.O. N.C. Common REX Single Door Module (SDM) SDM ERP40 Single Door Module Configurations • SDM – Single Door Controller – PoE Communication – Any Wiegand Card Technology or Biometric Reader – Door Status, REX, Door Lock Output • SDM “ER” series – Same as Above – Incorporated Reader • Proximity • Multi-Technology Single Cable Installation—SDM ER Series Controller • Ethernet or PoE • Door Lock Output • Door Sense Input • Request to Exit (REX) • Power Input Reader - Incorporated • Proximity • Multiclass Single Cable Application—SDM ERP Door Status Door Lock SDM To PoE Switch SDM—Controller ONLY Door Status SDM Lock Reader To PoE Switch Multi-Tenant Application Legacy System Upgrade Requirements • Latest System Software – LiNC-NXG, LiNC-Plus, LiNC-XS, EBI • Supported Legacy Controllers – IQ, SIM, ULT series controllers • Upgrade Controller Communications – LANU – Terminal Servers Fault Tolerance Architecture with Legacy Controllers Application Solutions with Fault Tolerant • • • • • • • • • Commercial High Rise Enterprise Systems Remote Managed Access Campus Environment Industrial Banking Government, HSPD compliant Cards High Reliability High Security Requirements