Transcript Document
GE Digital Energy Multilin 850 Feeder Protection System TM John Levine, P.E. Levine Lectronics and Lectric Contents • 8 Series Overview • Application Examples • Product Information Overview • 850 Order code • Summary 2 D20MX v1.2 Release 7/16/2015 MULTILIN 8 SERIES 3 Multilin 8 Series Platform Overview What is it? The Multilin 8 Series PlatformTM is GE’s next-generation global protection and control relay platform designed for industrial and utilities. The 8 Series platform is targeted to Oil & Gas, Mining, Pulp & Paper, Chemical, Water & Waste Water and Utility applications and provides comprehensive asset management for critical feeders, motors, generators and transformers. GE’s Differentiated Value Proposition Delivering the highest level of quality, reliability and performance with… Innovative Technology + Design: − Elimination of electrolytic capacitors − Advanced diagnostics with unique algorithms to ensure asset protection is never compromised − 2ms protection scans providing faster protection times for critical assets − Field swappable power supply simplifying fleet management − Low insertion force draw-out construction − Housed within an IP54 rated construction Interoperability: − Delivering the widest range of industry standard protocols simplifying integration in new and existing applications − Providing the latest in cyber security features allowing customers to comply with NERC CIP requirements − Secure Wi-Fi communications providing simplified connectivity during commissioning & diagnostics Detailed Diagnostics: − Improved electrical system insight with 128 sample / cycle, 8X the sample rate compared to traditional relays − Patented Environmental Awareness Module provide critical real-time data of Temperature, Humidity, Vibration and Surges the relay is exposed to Exceptional Quality + Reliability: − Rigorous test procedures and designed to IPC A-610 Class 3 Manufacturing standards − Extending relay life with standard conformal coating − 100% Electrical Stress Screening and full functional testing Service + Support: − Covered under GE’s new 10 Year Warranty Plan − Fully designed, tested and manufactured in North America 4 Multilin 850 Overview 5 APPLICATION EXAMPLES 6 Application: Industrial & Distribution Electrical Feeder Systems Challenge: • • • • Maintaining operational uptime Fast and accurate protection & Control schemes Require high speed communications Detailed diagnostic information Solution: • • • • • • Advanced technology & design techniques promoting increase relay life span With a protection pass time at 2ms close coordination with the electrical infrastructure is achieved protect the system High Speed communications with support for redundant communications, IEC61850 / PRP and two independent IP addresses Detailed diagnostics including 128 samples / cycle (8 x faster than traditional relays) to provide more in-depth analysis of power system disturbances Detailed breaker monitoring information is available to provides user with operation life information of the asset Environmental monitoring provides a detailed view of the operating environment of the relay including; ambient temperature, humidity, vibration and voltage surges 7 Application: Industrial Incoming Main-Tie-Main Application Challenge • Maintaining operational uptime with a loss of incoming feed • Fast and accurate transfer of incomers • Industry proven solution • Minimize required equipment and engineering time Solution • Integrated Main-Tie-Main scheme embedded in 850 Feeder Protection System • Using high speed communication and 850 flexibility M-T-M schemes are reduced to two primary relays • Built on industry proven transfer scheme • Reduced discrete devices and inter-wiring • Reduced and engineering resources • Maximize system and process availability • Fast, accurate and safe M-T-M scheme 8 Application: Distribution Auto Reclose Application Challenge • Maintain continuous system availability to downstream customers • Re-energize quickly during transient conditions • Coordinated auto-reclose functionality Solution: • • • • Comprehensive protection and auto-reclose capabilities Up to four auto reclose operations with programmable dead time Fully programmable to block IOC elements and to adjust curve characteristics of any TOC element Auto reclose shots can be reduced by high currents 9 Application: Zone Selective Interlocking Challenge • Maintaining high speed system coordination • Quickly and accurately detect and clear the fault • Reduce process or system downtime Solution • • • • • Embedded high speed IEC 61850 support High speed data exchange between 850 units Fast fault clearing times High speed & coordinated interlocked protection Minimum coordination delays 10 Application: Reliable detection of faults with CT saturation Challenge: • • SR 850 IOC Behavior on Saturated Currents with Fully DC Offset 70 Slow detection of faults causing CT saturation Fast clearance of faults CTR 50:5 50:5 75:5 75:5 100:5 100:5 60 Solution: • • • • Eight times per cycle update rate 64 samples per cycle resolution 46xCT conversion range Phasor and RMS input selection Fault Current (kA) 50 Vknee 5.5V 5.5V 10.0V 10.0V 12.2V 12.2V Quantity RMS Fundamental RMS Fundamental RMS Fundamental 150:5 20.0V RMS 150:5 20.0V Fundamental 40 30 20 10 0 0 5 10 15 20 25 30 35 40 45 50 55 Pickup Level ( x CT) 11 Application: Power Quality and System Disturbance Analytics 1.5 Current during Capacitor Bank Switch Recorded Current in 850 (128 s/c) Challenge: • • • • Inaccurate AC measurements Inaccurate power metering Bad quality recorded waveforms Low performance of protection functions Fault Current (A, Secondary) 1 0.5 0 -0.5 -1 Solution: • • • • Digital representation of the recorded measurements at 128 sample/cycle 2nd to 25th harmonic computation Total Harmonic Distortion (THD) computation Accurate power and Power Factor computation Accurate waveform records for analysis -1.5 0.19 0.2 0.21 0.22 0.23 0.24 0.25 0.26 Time (s) 1.5 Current during Capacitor Bank Switch Recorded Current in 16 s/c Relay 1 Fault Current (A, Secondary) • 0.5 0 -0.5 -1 -1.5 0.19 0.2 0.21 0.22 0.23 0.24 0.25 0.26 Time (s) 12 Application: High Speed IEC61850 / Parallel Redundancy Protocol (PRP) Application Challenge: • • Reducing probability of network failure Maintaining high speed communication Solution: • • • • • High reliability parallel network communications Reducing communication downtime Supported by IEC 61850 protocol Same data is sent via both networks No single point of failure 13 Application: Cyber Security with Radius Authentication • Cyber security aligned to standard industry practices resulting in seamless adoption and integration to existing Cyber Security applications Challenge: • • Maintaining system and operation security Eliminating unauthorized system access Access request: Role, User, password Encrypted (SSH) Authentication request: Role, User, password Solution: • The 850 meets NERC CIP cyber security requirements • RADIUS Authentication • Role Based Access Control • Password complexity Authentication request: Role, User, password Encrypted (SSH) 14 PRODUCT INFORMATION SUMMARY 15 8 Series – High Level Platform Information One Platform…Multiple Applications Applications within Platform: Reliability / Quality: • Feeder Protection • Motor, Generator, Transformer • High Reliability components • Rated –40 to +105ºC • Thermal & Reliability / Life Testing during development process • ALT & HALT Testing to ensure product reliability • 100% Complete Burn-in & Automated Final Test Rig • No Electrolytic Capacitors in complete unit Physical Information: • Same physical size as current SR • IP54 Rating • Draw out User Interface: • Full graphic control panel Protection cycle & data acquisition: Power Supply Information: • 128 sample / cycle for oscillography • 64 samples / cycle for protection • 1/8 cycle protection pass • 1/32 cycle for digital inputs • High Voltage: 88 to 300VDC / 60 to 300VAC • (no low voltage supply at this time) •Field Swappable • No Electrolytic Capacitors in PS or unit Logic: • 1024 Lines of Flexlogic 16 8 Series – High Level Platform Information One Platform…Multiple Applications Magnetics: Monitoring & Metering: • Max of 16 inputs (comb. of CT & VT) • Screw Terminals • Event Recorder: 1024 events • Oscillography: 128 samples/cycle • Motor, Generator, Transformer • Volt, Current, Power, Energy Inputs & Outputs: • 32 Digital Inputs • 16 Digital Outputs • Analog I/O support • Terminal Strip User Interface: • Full graphic control panel Onboard RTD’s: • RTD support for motor, generator & Transformer LED’s: • 14 multi-colored LED’s • 9 fixed & 5 programmable 17 8 Series – High Level Platform Information One Platform…Multiple Applications Communications: Asset Diagnostics: • IEC 61850, DNP 3.0, IEC 60870-5-103 & 104 • Modbus RTU & TCP/IP • IEC 62439/PRP • IEEE 1588, IRIG-B • RS485 • 2 Ethernet • Serial, Fiber and Copper • USB front port • Wireless (optional for relay configuration) • Breaker wear, travel time • Operation counter, Spring charge time • Broken rotor bar detection • Stator turn fault, Bearing failure • Loss of Life, Hot Spot • Winding Failure Cyber Security: • Remote authentication via Radius • Security Audit Trail • Role based access Environmental Diagnostics: • Environmental Monitoring • Temperature monitoring • Humidity monitoring • Surge monitoring • Vibration monitoring 18 850 Feeder Protection System – Typical Wiring 19 850 Feeder Protection System “Advanced Feeder Protection for Industrial and Distribution Utilities ” Typical Applications: • Oil and Gas • Mining • Cement • WTP / WWTP • Pulp and Paper • IOU / Distribution Utilities • Data Centers • Balance of Plant 20 850 Feeder Protection System – Protection & Control Functions 21 850 Feeder Protection System – Front View 22 850 Feeder Protection System – Rear View 23 850 Feeder Protection System - Dimensions 24 850 ORDER CODE 25 How to Order & Lead-time 26 Pricing 850 Feeder Protection System Order Code: Details Approximate Lead Time: 850-E-P5-NN-G5-H-N-N-A-N-N-G-S-P-BB-SE-N-N-B-N Quantity: Edit Copy $ 3173.1 1 Remove Extended Price: $3,173.10 30 business day(s) Configuration Details: Language: E - English Phase Current - Bank 1/2: P5 - 5A Three Phase Current Inputs Phase Current - Bank 3: NN - No phase current inputs Ground Current: G5 - 5A Ground Current Input Power Supply: H - 110 - 250 VDC / 110 - 230 VAC Slot B - LV I/O: N - None Slot C - LV I/O: N - None Slot F - HV I/O: A - 2 Form A (Vmon), 3 Form C, 7 Digital Inputs (Low / High voltage, Int/Ext supply) Slot G - HV I/O: N - None Slot H - HV I/O: N - None Faceplate: G - Color Graphical Display Current Protection: S - Basic = 50P, 50N, 50G, 51P, 51N, 51G Voltage Monitoring & Protection: P - Advanced = Standard + 25, 32, 32N, 55, 59_2, 81R Control: B - Basic Monitoring: B - Basic Communications: SE - Standard = Basic + 1 x Ethernet (Modbus TCP, SNTP), RMIO Fiber Optic Connector: N - None Wireless Communication: N - None Security: B - Basic Special Options: Language: English 750 without Ethernet $3214 750 with Ethernet $3516 27 10 YEAR WARRANTY OVERVIEW 28 Warranty Overview 10 Year Warranty For all sales (shipments) on or after October 1, 2013, GE Digital Energy warrants all GE manufactured Protection and Control and Automation (Substation Automation) Products for 10 year period. The 10 Year Warranty includes most products such as: • 8 Series • UR • UR Plus • SR, SR3 • Single Function Protection/Auxiliary Relays • Industrial Meters: EPM, PQM Meters • Industrial Communications: MultiLink Ethernet Switches • Network/Media and Protocol Converters • Gateways/RTUs • IEC 61850 Process Bus Some existing warranties and product exclusions apply as per Terms and Conditions ES104 10 Year Warranty Effective Value Proposition Worldwide 10 Year Warranty - Showcases continuous improvement of Quality and Customer Focused Innovation - Improves customer experience with Warranty service issues and decreases maintenance costs - Highlights the availability of our Technical Support organization to respond to customer challenges Oct. 1, 2013 29 SUMMARY 30 Multilin 850 Platform Summary GE’s 850 Differentiated Value Proposition Delivering the highest level of quality, reliability and performance with… Innovative Technology & Design…Elimination of electrolytic capacitors, advanced diagnostic algorithms and a field swappable power supply to simplify device fleet management Exceptional Quality & Reliability…Designed and manufactured to IPC A-610 Class 3 standards and adhering to the highest reliability standards with 100% Electrical Stress Screening (ESS) of each device Interoperability and Flexibility…Providing the widest range of industry standard protocols and the latest in security features allows customers to comply with NERC CIP and NITIR 7628 requirements Advanced Asset Diagnostics…The Patented Environmental Awareness Module providing critical real-time data of environmental conditions in addition to 128 sample / cycle, (8X the sample rate compared to traditional relays), providing detailed insight into operating conditions. Uncompromised Service and Support…fully designed, testing and manufactured in North America and backed by GE’s 10 year warranty 31 Software 32 QUESTIONS? 33 THANK YOU 34