Transcript Document

GE
Digital Energy
Multilin 850
Feeder Protection System
TM
John Levine, P.E.
Levine Lectronics and Lectric
Contents
• 8 Series Overview
• Application Examples
• Product Information Overview
• 850 Order code
• Summary
2
D20MX v1.2 Release
7/16/2015
MULTILIN 8 SERIES
3
Multilin 8 Series Platform Overview
What is it?
The Multilin 8 Series PlatformTM is GE’s next-generation global protection and control
relay platform designed for industrial and utilities.
The 8 Series platform is targeted to Oil & Gas, Mining, Pulp & Paper, Chemical, Water &
Waste Water and Utility applications and provides comprehensive asset management for
critical feeders, motors, generators and transformers.
GE’s Differentiated Value Proposition
Delivering the highest level of quality, reliability and performance with…
Innovative Technology + Design:
− Elimination of electrolytic capacitors
− Advanced diagnostics with unique algorithms to
ensure asset protection is never compromised
− 2ms protection scans providing faster protection
times for critical assets
− Field swappable power supply simplifying fleet
management
− Low insertion force draw-out construction
− Housed within an IP54 rated construction
Interoperability:
− Delivering the widest range of industry standard
protocols simplifying integration in new and existing
applications
− Providing the latest in cyber security features allowing
customers to comply with NERC CIP requirements
− Secure Wi-Fi communications providing simplified
connectivity during commissioning & diagnostics
Detailed Diagnostics:
− Improved electrical system insight with 128 sample /
cycle, 8X the sample rate compared to traditional
relays
− Patented Environmental Awareness Module provide
critical real-time data of Temperature, Humidity,
Vibration and Surges the relay is exposed to
Exceptional Quality + Reliability:
− Rigorous test procedures and designed to IPC A-610
Class 3 Manufacturing standards
− Extending relay life with standard conformal coating
− 100% Electrical Stress Screening and full functional
testing
Service + Support:
− Covered under GE’s new 10 Year Warranty Plan
− Fully designed, tested and manufactured in North
America
4
Multilin 850 Overview
5
APPLICATION EXAMPLES
6
Application: Industrial & Distribution Electrical Feeder Systems
Challenge:
•
•
•
•
Maintaining operational uptime
Fast and accurate protection & Control schemes
Require high speed communications
Detailed diagnostic information
Solution:
•
•
•
•
•
•
Advanced technology & design techniques
promoting increase relay life span
With a protection pass time at 2ms close
coordination with the electrical infrastructure
is achieved protect the system
High Speed communications with support for
redundant communications, IEC61850 / PRP
and two independent IP addresses
Detailed diagnostics including 128 samples /
cycle (8 x faster than traditional relays) to
provide more in-depth analysis of power
system disturbances
Detailed breaker monitoring information is
available to provides user with operation life
information of the asset
Environmental monitoring provides a detailed
view of the operating environment of the relay
including; ambient temperature, humidity,
vibration and voltage surges
7
Application: Industrial Incoming Main-Tie-Main Application
Challenge
• Maintaining operational uptime with a loss of
incoming feed
• Fast and accurate transfer of incomers
• Industry proven solution
• Minimize required equipment and engineering time
Solution
• Integrated Main-Tie-Main scheme embedded in 850
Feeder Protection System
• Using high speed communication and 850 flexibility
M-T-M schemes are reduced to two primary relays
• Built on industry proven transfer scheme
• Reduced discrete devices and inter-wiring
• Reduced and engineering resources
• Maximize system and process availability
• Fast, accurate and safe M-T-M scheme
8
Application: Distribution Auto Reclose Application
Challenge
• Maintain continuous system availability to
downstream customers
• Re-energize quickly during transient conditions
• Coordinated auto-reclose functionality
Solution:
•
•
•
•
Comprehensive protection and auto-reclose
capabilities
Up to four auto reclose operations with
programmable dead time
Fully programmable to block IOC elements and to
adjust curve characteristics of any TOC element
Auto reclose shots can be reduced by high currents
9
Application: Zone Selective Interlocking
Challenge
• Maintaining high speed system coordination
• Quickly and accurately detect and clear the fault
• Reduce process or system downtime
Solution
•
•
•
•
•
Embedded high speed IEC 61850 support
High speed data exchange between 850 units
Fast fault clearing times
High speed & coordinated interlocked protection
Minimum coordination delays
10
Application: Reliable detection of faults with CT saturation
Challenge:
•
•
SR 850 IOC Behavior on Saturated Currents with Fully DC Offset
70
Slow detection of faults causing CT saturation
Fast clearance of faults
CTR
50:5
50:5
75:5
75:5
100:5
100:5
60
Solution:
•
•
•
•
Eight times per cycle update rate
64 samples per cycle resolution
46xCT conversion range
Phasor and RMS input selection
Fault Current (kA)
50
Vknee
5.5V
5.5V
10.0V
10.0V
12.2V
12.2V
Quantity
RMS
Fundamental
RMS
Fundamental
RMS
Fundamental
150:5 20.0V RMS
150:5 20.0V Fundamental
40
30
20
10
0
0
5
10
15
20
25
30
35
40
45
50
55
Pickup Level ( x CT)
11
Application: Power Quality and System Disturbance Analytics
1.5
Current during Capacitor Bank Switch
Recorded Current in 850 (128 s/c)
Challenge:
•
•
•
•
Inaccurate AC measurements
Inaccurate power metering
Bad quality recorded waveforms
Low performance of protection functions
Fault Current (A, Secondary)
1
0.5
0
-0.5
-1
Solution:
•
•
•
•
Digital representation of the recorded measurements at
128 sample/cycle
2nd to 25th harmonic computation
Total Harmonic Distortion (THD) computation
Accurate power and Power Factor computation
Accurate waveform records for analysis
-1.5
0.19
0.2
0.21
0.22
0.23
0.24
0.25
0.26
Time (s)
1.5
Current during Capacitor Bank Switch
Recorded Current in 16 s/c Relay
1
Fault Current (A, Secondary)
•
0.5
0
-0.5
-1
-1.5
0.19
0.2
0.21
0.22
0.23
0.24
0.25
0.26
Time (s)
12
Application: High Speed IEC61850 / Parallel Redundancy
Protocol (PRP) Application
Challenge:
•
•
Reducing probability of network failure
Maintaining high speed communication
Solution:
•
•
•
•
•
High reliability parallel network communications
Reducing communication downtime
Supported by IEC 61850 protocol
Same data is sent via both networks
No single point of failure
13
Application: Cyber Security with Radius Authentication
• Cyber security aligned to standard
industry practices resulting in
seamless adoption and integration
to existing Cyber Security
applications
Challenge:
•
•
Maintaining system and operation security
Eliminating unauthorized system access
Access request:
Role, User,
password
Encrypted (SSH)
Authentication
request: Role,
User, password
Solution:
•
The 850 meets NERC CIP cyber security
requirements
• RADIUS Authentication
• Role Based Access Control
• Password complexity
Authentication
request: Role,
User, password
Encrypted (SSH)
14
PRODUCT INFORMATION SUMMARY
15
8 Series – High Level Platform Information
One Platform…Multiple Applications
Applications within Platform:
Reliability / Quality:
• Feeder Protection
• Motor, Generator, Transformer
• High Reliability components
• Rated –40 to +105ºC
• Thermal & Reliability / Life Testing
during development process
• ALT & HALT Testing to ensure product
reliability
• 100% Complete Burn-in & Automated
Final Test Rig
• No Electrolytic Capacitors in complete unit
Physical Information:
• Same physical size as current SR
• IP54 Rating
• Draw out
User Interface:
• Full graphic control panel
Protection cycle & data acquisition:
Power Supply Information:
• 128 sample / cycle for oscillography
• 64 samples / cycle for protection
• 1/8 cycle protection pass
• 1/32 cycle for digital inputs
• High Voltage: 88 to 300VDC / 60 to 300VAC
• (no low voltage supply at this time)
•Field Swappable
• No Electrolytic Capacitors in PS or unit
Logic:
• 1024 Lines of Flexlogic
16
8 Series – High Level Platform Information
One Platform…Multiple Applications
Magnetics:
Monitoring & Metering:
• Max of 16 inputs (comb. of CT & VT)
• Screw Terminals
• Event Recorder: 1024 events
• Oscillography: 128 samples/cycle
• Motor, Generator, Transformer
• Volt, Current, Power, Energy
Inputs & Outputs:
• 32 Digital Inputs
• 16 Digital Outputs
• Analog I/O support
• Terminal Strip
User Interface:
• Full graphic control panel
Onboard RTD’s:
• RTD support for motor, generator & Transformer
LED’s:
• 14 multi-colored LED’s
• 9 fixed & 5 programmable
17
8 Series – High Level Platform Information
One Platform…Multiple Applications
Communications:
Asset Diagnostics:
• IEC 61850, DNP 3.0, IEC 60870-5-103 & 104
• Modbus RTU & TCP/IP
• IEC 62439/PRP
• IEEE 1588, IRIG-B
• RS485
• 2 Ethernet
• Serial, Fiber and Copper
• USB front port
• Wireless (optional for relay configuration)
• Breaker wear, travel time
• Operation counter, Spring charge time
• Broken rotor bar detection
• Stator turn fault, Bearing failure
• Loss of Life, Hot Spot
• Winding Failure
Cyber Security:
• Remote authentication via Radius
• Security Audit Trail
• Role based access
Environmental Diagnostics:
• Environmental Monitoring
• Temperature monitoring
• Humidity monitoring
• Surge monitoring
• Vibration monitoring
18
850 Feeder Protection System – Typical Wiring
19
850 Feeder Protection System
“Advanced Feeder Protection for Industrial and Distribution Utilities ”
Typical Applications:
• Oil and Gas
• Mining
• Cement
• WTP / WWTP
• Pulp and Paper
• IOU / Distribution Utilities
• Data Centers
• Balance of Plant
20
850 Feeder Protection System – Protection & Control Functions
21
850 Feeder Protection System – Front View
22
850 Feeder Protection System – Rear View
23
850 Feeder Protection System - Dimensions
24
850 ORDER CODE
25
How to Order & Lead-time
26
Pricing
850 Feeder Protection System
Order Code:
Details
Approximate
Lead Time:
850-E-P5-NN-G5-H-N-N-A-N-N-G-S-P-BB-SE-N-N-B-N
Quantity:
Edit
Copy
$ 3173.1
1
Remove
Extended Price:
$3,173.10
30 business
day(s)
Configuration Details:
Language: E - English
Phase Current - Bank 1/2: P5 - 5A Three Phase
Current Inputs
Phase Current - Bank 3: NN - No phase current
inputs
Ground Current: G5 - 5A Ground Current Input
Power Supply: H - 110 - 250 VDC / 110 - 230
VAC
Slot B - LV I/O: N - None
Slot C - LV I/O: N - None
Slot F - HV I/O: A - 2 Form A (Vmon), 3 Form C,
7 Digital Inputs (Low / High voltage, Int/Ext
supply)
Slot G - HV I/O: N - None
Slot H - HV I/O: N - None
Faceplate: G - Color Graphical Display
Current Protection: S - Basic = 50P, 50N, 50G,
51P, 51N, 51G
Voltage Monitoring & Protection: P - Advanced =
Standard + 25, 32, 32N, 55, 59_2, 81R
Control: B - Basic
Monitoring: B - Basic
Communications: SE - Standard = Basic + 1 x
Ethernet (Modbus TCP, SNTP), RMIO
Fiber Optic Connector: N - None
Wireless Communication: N - None
Security: B - Basic
Special Options:
Language: English
750 without Ethernet $3214
750 with Ethernet $3516
27
10 YEAR WARRANTY OVERVIEW
28
Warranty Overview
10 Year Warranty
For all sales (shipments) on or after October 1, 2013, GE
Digital Energy warrants all GE manufactured Protection and
Control and Automation (Substation Automation) Products
for 10 year period.
The 10 Year Warranty includes most products such as:
• 8 Series
• UR
• UR Plus
• SR, SR3
• Single Function Protection/Auxiliary Relays
• Industrial Meters: EPM, PQM Meters
• Industrial Communications: MultiLink Ethernet Switches
• Network/Media and Protocol Converters
• Gateways/RTUs
• IEC 61850 Process Bus
Some existing warranties and product exclusions apply as per
Terms and Conditions ES104
10 Year Warranty Effective
Value Proposition
Worldwide 10 Year Warranty
- Showcases continuous improvement of
Quality and Customer Focused Innovation
- Improves customer experience with
Warranty service issues and decreases
maintenance costs
- Highlights the availability of our Technical
Support organization to respond to
customer challenges
Oct. 1, 2013
29
SUMMARY
30
Multilin 850 Platform Summary
GE’s 850 Differentiated Value Proposition
Delivering the highest level of quality, reliability and performance with…
Innovative Technology & Design…Elimination of electrolytic capacitors, advanced diagnostic
algorithms and a field swappable power supply to simplify device fleet management
Exceptional Quality & Reliability…Designed and manufactured to IPC A-610 Class 3 standards
and adhering to the highest reliability standards with 100% Electrical Stress Screening (ESS) of
each device
Interoperability and Flexibility…Providing the widest range of industry standard protocols and
the latest in security features allows customers to comply with NERC CIP and NITIR 7628
requirements
Advanced Asset Diagnostics…The Patented Environmental Awareness Module providing critical
real-time data of environmental conditions in addition to 128 sample / cycle, (8X the sample rate
compared to traditional relays), providing detailed insight into operating conditions.
Uncompromised Service and Support…fully designed, testing and manufactured in North
America and backed by GE’s 10 year warranty
31
Software
32
QUESTIONS?
33
THANK YOU
34