Folie 1 - Bulclima Ltd.
Download
Report
Transcript Folie 1 - Bulclima Ltd.
VITALITY
Large Splits
1
Johnson Controls PowerPoint Guidelines | July 21, 2009
Large Splits
Axial Condensing fan
Benefits:
Split system from 20 to 90 kW
Ductable indoor unit
Auxiliar heating (elect heater or hot water coil) available
Allows ventilation, free cooling available
Where to apply / typical market:
As an universal condensing unit to match with other systems (evaporator of a AHU)
For offices where duct installation is the preferred solution against chiller+FCU or multiple minisplits
Typical installations are anyplace where AHU is fitted, industry,
petrol stations
2
Large Splits
Centrifugal Condensing fan
Benefits:
Split system from 20 to 90 kW
Ductable indoor unit
Auxiliar heating (elect heater or hot water coil) available
Allows ventilation, free cooling available
Indoor can be installed on top of the outdoor unit (compact solution)
Where to apply / typical market:
As an universal condensing unit to match with other systems (evaporator of a AHU)
Indoor Installations in technical room (to prevent from extreme outdoor temps or to install low noise
kits or no outdoor inst possible)
For office buildings, supermarkets …
3
LARGE SPLIT CENTRIFUGAL FAN – VCH
Main Advantages / Features
R410A Refrigerant
Improved efficiency and reduced noise level
YKLON V3 board
Designed to service (service valves, improved
accessibility)
Vertical or horizontal discharge
50m pipe length
New options and accessories
Economizer
Return fan
Hot water coil and control (0-10V, 4 stages)
5
Johnson Controls
Large Splits
Centrifugal Condensing fan
Access to components
Stop valves
Service valves
8
Johnson Controls
Large Splits
Centrifugal Condensing fan
• Access to components
Electrical box
Motor
TEV’s
Belt / Pulley
Sight glass
Elec. channel
Compressors
Service valves
9
Johnson Controls
Filter Drier
Cabling
Piping
Large Splits
Centrifugal Condensing fan
• Low ambient control (down to – 10°C)
Actuator
Control
Damper Low Ambient regulation *
* Not suitable for outdoor application
10
Johnson Controls
Large Splits
Axial Condensing fan
Main Advantages & Features Vs SOC/SOH + SICH
R410A Refrigerant
Improved efficiency
Quiet operation
Shares same indoor unit as VCH -> VIR
Long pipe run (up to 50m)
New size 20 kW
New PCB YKN2Open (JCI protocol)
New options and accessories
Soft Start Compressor for outdoor unit
LAK as option (before as standard)
11
Johnson Controls
Large Splits
Axial Condensing fan
Outdoor Fan: High efficiency, Low noise operation condenser fan.
15
Johnson Controls
Large Splits
Axial Condensing fan
Compressor Soft Start: It is only needed to do the wiring connections. It
comes automatically adjusted from factory to the optimal point
Provides alarm signal in case of:
- Wrong phase sequence
- Low voltage
- Frequency out of range
- Locked rotor
- overheating
…
16
Johnson Controls
Large Splits
Axial Condensing fan
LAK Condenser fan: From Jonhson Controls, model P215PR, it is
deileved at 26 bar by default.
Needed 1 per circuit.
17
Johnson Controls
Large Splits
Axial Condensing fan
LAK Condenser fan: From Jonhson Controls, model P215P, it is
deileved regulated at 26 bar.
18
Johnson Controls
Large Splits
Indoor unit VIR
Main Advantages / Features
R410A Refrigerant
High efficiency & reduced noise level
High Static Pressure Available
Designed to service
Vertical or horizontal discharge
Possibility to install on top of condensing unit
centrifugal fan
Accessories:
Economizer
Electrical heater
Hot water coil and control (0-10V, 4 stages)
Return fan
High speed drive
19
Johnson Controls
Large Splits
Indoor unit VIR
• Air filter
G3 filter with handle
Mechanical fastening easy to remove
1
Pull
20
Johnson Controls
Filters connection
2
Large Splits
Indoor unit VIR
• Access to components
TEV’s
Piping
Motor
Belt / Pulley
21
Johnson Controls
Large Splits
Indoor unit VIR
• Access to components
TEV’s
Hot water valve
& Actuator
Motor
Belt / Pulley
22
Johnson Controls
Piping
Large Splits
Indoor unit VIR
• Access to components
TEV’s
Safety
thermostats
Piping
Electrical box
Motor
Belt / Pulley
23
Johnson Controls
Large Splits
Indoor unit VIR
• Economizer & return fan
Economizer can be assembled alone with
the unit
Return fan needs to be ordered always with
return fan
24
Johnson Controls
Large Splits
Indoor unit VIR
• Hot water coil
• Modulating valve with 4 stages:
- Stage 1: Supply air 30°C
- Stage 2: Supply air 40°C
- Stage 3: Supply air 45°C
- Stage 4: Supply air 50°C
& Hot water coil minimum supply air temperature 15°C
• Anti freeze protection:
- If water temperature < 3°C, water pump and water valve are activated open
- Antifreeze protection stop when water > 6°C
• Jumper S2 give priority heat stages:
- jumper OFF: Heat pump compressors 1st and 2nd heat stage
- jumper ON: Hot water coil 1st heat stage
25
Johnson Controls
Large Splits
Indoor unit VIR
• Electrical heater
Box tap with ventilating windows
Contactor in 24V
All heater inside the VIR, after evaporator coil (between fans phased out)
The heater board to be installed on site in the outdoor unit
2 x 0,75 mm2 cable to protect against EMC uncertainty
All components at the opposite of refrigerating tubing for easy service
26
Johnson Controls
Large Splits
Indoor unit VIR
• Indoor soft start
27
Johnson Controls
Large Splits
Indoor unit VIR
• Standard & High Speed Drive VIR’s
Minimum Airflow
Nominal Airflow
Maximum Airflow
Indoor fan power input
Available static pressure
28
Johnson Controls
Large Splits
Indoor unit VIR
• Vertical discharge VIR’s
29
Johnson Controls
Large Splits
Competitors Benchmark
Large Splits Competitor Benchmark
Chart comparison – EER Vs Capacity
34
Johnson Controls
Large Splits Competitor Benchmark
Chart comparison – COP Vs Capacity
35
Johnson Controls
Large Splits Competitor Benchmark
Chart comparison – Sound Power (LwA) Vs Capacity
36
Johnson Controls
THANKS FOR YOUR ATTENTION!
37
Johnson Controls PowerPoint Guidelines | July 21, 2009