Folie 1 - Bulclima Ltd.

Download Report

Transcript Folie 1 - Bulclima Ltd.

VITALITY
Large Splits
1
Johnson Controls PowerPoint Guidelines | July 21, 2009
Large Splits
Axial Condensing fan
Benefits:
 Split system from 20 to 90 kW
 Ductable indoor unit
 Auxiliar heating (elect heater or hot water coil) available
 Allows ventilation, free cooling available
Where to apply / typical market:
 As an universal condensing unit to match with other systems (evaporator of a AHU)
 For offices where duct installation is the preferred solution against chiller+FCU or multiple minisplits
 Typical installations are anyplace where AHU is fitted, industry,
petrol stations
2
Large Splits
Centrifugal Condensing fan
Benefits:
 Split system from 20 to 90 kW
 Ductable indoor unit
 Auxiliar heating (elect heater or hot water coil) available
 Allows ventilation, free cooling available
 Indoor can be installed on top of the outdoor unit (compact solution)
Where to apply / typical market:
 As an universal condensing unit to match with other systems (evaporator of a AHU)
 Indoor Installations in technical room (to prevent from extreme outdoor temps or to install low noise
kits or no outdoor inst possible)
 For office buildings, supermarkets …
3
LARGE SPLIT CENTRIFUGAL FAN – VCH
Main Advantages / Features
 R410A Refrigerant
 Improved efficiency and reduced noise level
 YKLON V3 board
 Designed to service (service valves, improved
accessibility)
 Vertical or horizontal discharge
 50m pipe length
 New options and accessories
 Economizer
 Return fan
 Hot water coil and control (0-10V, 4 stages)
5
Johnson Controls
Large Splits
Centrifugal Condensing fan
Access to components
Stop valves
Service valves
8
Johnson Controls
Large Splits
Centrifugal Condensing fan
• Access to components
Electrical box
Motor
TEV’s
Belt / Pulley
Sight glass
Elec. channel
Compressors
Service valves
9
Johnson Controls
Filter Drier
Cabling
Piping
Large Splits
Centrifugal Condensing fan
• Low ambient control (down to – 10°C)
Actuator
Control
Damper Low Ambient regulation *
* Not suitable for outdoor application
10
Johnson Controls
Large Splits
Axial Condensing fan
Main Advantages & Features Vs SOC/SOH + SICH
 R410A Refrigerant
 Improved efficiency
 Quiet operation
 Shares same indoor unit as VCH -> VIR
 Long pipe run (up to 50m)
 New size 20 kW
 New PCB YKN2Open (JCI protocol)
 New options and accessories
 Soft Start Compressor for outdoor unit
 LAK as option (before as standard)
11
Johnson Controls
Large Splits
Axial Condensing fan
Outdoor Fan: High efficiency, Low noise operation condenser fan.
15
Johnson Controls
Large Splits
Axial Condensing fan
Compressor Soft Start: It is only needed to do the wiring connections. It
comes automatically adjusted from factory to the optimal point
Provides alarm signal in case of:
- Wrong phase sequence
- Low voltage
- Frequency out of range
- Locked rotor
- overheating
…
16
Johnson Controls
Large Splits
Axial Condensing fan
LAK Condenser fan: From Jonhson Controls, model P215PR, it is
deileved at 26 bar by default.
Needed 1 per circuit.
17
Johnson Controls
Large Splits
Axial Condensing fan
LAK Condenser fan: From Jonhson Controls, model P215P, it is
deileved regulated at 26 bar.
18
Johnson Controls
Large Splits
Indoor unit VIR
Main Advantages / Features
 R410A Refrigerant
 High efficiency & reduced noise level
 High Static Pressure Available
 Designed to service
 Vertical or horizontal discharge
 Possibility to install on top of condensing unit
centrifugal fan
 Accessories:
 Economizer
 Electrical heater
 Hot water coil and control (0-10V, 4 stages)
 Return fan
 High speed drive
19
Johnson Controls
Large Splits
Indoor unit VIR
• Air filter
 G3 filter with handle
 Mechanical fastening easy to remove
1
Pull
20
Johnson Controls
Filters connection
2
Large Splits
Indoor unit VIR
• Access to components
TEV’s
Piping
Motor
Belt / Pulley
21
Johnson Controls
Large Splits
Indoor unit VIR
• Access to components
TEV’s
Hot water valve
& Actuator
Motor
Belt / Pulley
22
Johnson Controls
Piping
Large Splits
Indoor unit VIR
• Access to components
TEV’s
Safety
thermostats
Piping
Electrical box
Motor
Belt / Pulley
23
Johnson Controls
Large Splits
Indoor unit VIR
• Economizer & return fan
 Economizer can be assembled alone with
the unit
 Return fan needs to be ordered always with
return fan
24
Johnson Controls
Large Splits
Indoor unit VIR
• Hot water coil
• Modulating valve with 4 stages:
- Stage 1: Supply air 30°C
- Stage 2: Supply air 40°C
- Stage 3: Supply air 45°C
- Stage 4: Supply air 50°C
& Hot water coil minimum supply air temperature 15°C
• Anti freeze protection:
- If water temperature < 3°C, water pump and water valve are activated open
- Antifreeze protection stop when water > 6°C
• Jumper S2 give priority heat stages:
- jumper OFF: Heat pump compressors 1st and 2nd heat stage
- jumper ON: Hot water coil 1st heat stage
25
Johnson Controls
Large Splits
Indoor unit VIR
• Electrical heater
 Box tap with ventilating windows
 Contactor in 24V
 All heater inside the VIR, after evaporator coil (between fans phased out)
 The heater board to be installed on site in the outdoor unit
 2 x 0,75 mm2 cable to protect against EMC uncertainty
 All components at the opposite of refrigerating tubing for easy service
26
Johnson Controls
Large Splits
Indoor unit VIR
• Indoor soft start
27
Johnson Controls
Large Splits
Indoor unit VIR
• Standard & High Speed Drive VIR’s
Minimum Airflow
Nominal Airflow
Maximum Airflow
Indoor fan power input
Available static pressure
28
Johnson Controls
Large Splits
Indoor unit VIR
• Vertical discharge VIR’s
29
Johnson Controls
Large Splits
Competitors Benchmark
Large Splits Competitor Benchmark
Chart comparison – EER Vs Capacity
34
Johnson Controls
Large Splits Competitor Benchmark
Chart comparison – COP Vs Capacity
35
Johnson Controls
Large Splits Competitor Benchmark
Chart comparison – Sound Power (LwA) Vs Capacity
36
Johnson Controls
THANKS FOR YOUR ATTENTION!
37
Johnson Controls PowerPoint Guidelines | July 21, 2009