The NatVent
Buildings
Work package 2
Objectives of
WP 2
19 naturally
ventilated
buildings
The monitoring
campaigns
The monitoring
results
Select a
building...
Final
conclusions
JOULE
NatVent
Performance of naturally
ventilated buildings
The NatVent
Buildings
WP2 - Objectives
Objectives of
WP 2
19 naturally
ventilated
buildings
The monitoring
campaigns
The aim of this work package was:
 To evaluate the performance of existing ad-hoc buildings designed
and constructed specifically as energy-efficient naturally ventilated
buildings
 To identify the advantages and shortcomings of natural ventilation
strategies
The monitoring
results
Select a
building...
 To specify the overall design and construction conditions required for
Final
conclusions
JOULE
NatVent
achieving successful natural ventilation
The NatVent
Buildings
19 Monitored Buildings...

Objectives of
WP 2
19 naturally ventilated buildings were selected from seven EU
countries.
Overview of the 19 buildings:
19 naturally
ventilated
buildings

Belgium: BE1 - BE2 - BE3
The monitoring
campaigns

Switzerland: CH1 - CH2 - CH3

Denmark: DK1 -DK2 - DK3
The monitoring
results

Great Britain: GB1- GB2 -GB3

Norway: NO1 - NO2

The Netherlands: NL1 - NL2 - NL3

Sweden: SE1 - SE2
Select a
building...
Final
conclusions
JOULE
NatVent
An overview of 19 buildings is given in the document
overview.pdf (\Reports\Monitoring\...)
The NatVent
Buildings
The Monitoring Campaigns
Objectives of
WP 2

The 19 buildings selected were monitored under winter and summer
conditions

The following parameters were measured in all of the buildings:
 Temperature
 Internal air quality (H2O, CO2, …)
 Ventilation rate
 Wind outdoor: direction and velocity
 Wind indoor: velocity

The parameters were measured in 4 rooms and 1 corridor for a
minimum of one week
19 naturally
ventilated
buildings
The monitoring
campaigns
The monitoring
results
Select a
building...
Final
conclusions
JOULE
NatVent
The basic monitoring set-up and the monitoring
protocol is described in document
monitor_protoc.pdf (\Reports\Monitoring\…)
The NatVent
Buildings
WP2 - Monitoring Results
The results of the monitoring programmes are presented in the following
documents:
Objectives of
WP 2
19 naturally
ventilated
buildings
Summary Reports
(\Reports \Monitoring Reports \Summary Reports\…)


The monitoring
campaigns
The monitoring
results
global presentation of the buildings ( 4p./ building)
contents: building description - ventilation strategy and technology - winter and
summer monitoring results - conclusions
Detailed Reports
(\Reports \Monitoring Reports \Detailed Reports\…)
Select a
building...
Final
conclusions
JOULE
NatVent


detailed reports of all 19 monitoring campaigns ( 20 p./ campaign)
contents: monitoring set up - analysis of results - conclusions
You can read and print pdf-files with the Acrobat® Reader ®3.0. Program. This
program is free.
Download it from the Acrobat web site: www.adobe.com OR run the installation
file ar32e301(1).exe in the directory \Installation
Select a Building...
BE1: PROBE Building
GB2: Canning Crescent Centre
BE2: Keppekouter Building
GB3: Portland Street Building
BE3: Renson Headquarters
NO1: Ulleval Administration Build.
CH1: VELUX Building
NO2: Pfizer Building
CH2: EWZ Building
NL1: European Patent Office
CH3: Basler Versicherungen Building
NL2: Town Hall of Zevenhuizen-M.
DK1: E.Pihl & Son AS Headquarters
NL3: Tax Office of Enschede
DK2: BRF Kredit Headquarters
SE1: Tage Møller Building
DK3: WindowMaster Office Build.
SE2: Technical Office of Varberg
GB1: BRE Energy Efficient Office
NatVent
The NatVent
Buildings
Final Conclusions (1...)
There were 8 key findings from the 19 building monitoring
programme:
Objectives of
WP 2
19 naturally
ventilated
buildings
The monitoring
campaigns
The monitoring
results
Select a
building...
Final
conclusions
JOULE
NatVent
1. The challenge is to provide comfortable conditions within an energy
efficient building.
2. It is essential to understand what natural ventilation actually is.
3. Ventilation for IAQ should optimise both IAQ and energy efficiency
4. The required air flow rates for summer comfort are much higher than
for IAQ control and the thermal mass of the building must be
accessible
The NatVent
Buildings
Final Conclusions (2|)
5. Achieving comfortable conditions in the summer requires more than
just high ventilation rates
Objectives of
WP 2
19 naturally
ventilated
buildings
The monitoring
campaigns
The monitoring
results
Select a
building...
Final
conclusions
JOULE
NatVent
6. Successful design involves more than simply estimating air flow rates
7. The creation of an attractive environment for innovation is extremely
important
8. Natural ventilation can be an attractive option, but NOT the only
option
You can find more information in the Final Monitoring Report
(final_monitor_rep.pdf) in the directory \Reports\Monitoring
You can read and print pdf-files with the Acrobat® Reader ®3.0. Program. This
program is free.
Download it from the Acrobat web site: www.adobe.com OR run the installation
file ar32e301(1).exe in the directory \Installation