Bosch Solution 16i
Intrusion Control System
1
Features & Benefits
Quick Specs - Solution 16i

New Bosch Text / ICON User Interface
16 RF or Hard Wired Zones in total
4 Areas
4 outputs on board
48 Users

Options











2
1A power supply
Input expansion module - 16 zones
Output expansion module - 8 outputs
Proximity Readers in Code pads
Night arm station
Voice Command Module
Conettix IP Module
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Features & Benefits
Bosch Text-Icon Code Pad
3

Combines industry leading ICON interface
with text display.

Full programming from the code pad
facilitates easy installation and maintenance

Customers familiar with icon code pad
programming will directly relate to the panel
reducing training requirements

Multi area control and status display of all
areas on all code pads reduces inventory as
only one code pad is required. Maintenance
is available from any code pad in the
building reducing labour.

Optional proximity reader versions reduces
false alarms due to user error
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Features & Benefits
Wired or Wireless Inputs

Flexible configuration of both wired and wireless
inputs facilitates easy installation and
customisation to the unique needs of each
installation
Wired input features






Selectable EOL values
Single EOL, dual / split EOL (8 zone expansion
module)
Alarm + tamper 4 state monitoring
Separate tamper input
PGM input for RF and key-switch
Sensor watch alert
Wireless input features




4
Any combination of wired or wireless in any area
RF supervision
Easy enrolment of devices – learn or key in
Multi RF receiver card 3 x RX (CM195)
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Refer to page 3 -1
of your manual
Bosch Security Systems
Refer to page 3 -4
of your manual
5
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Features & Benefits
Communications

Flexible and multiple reporting options are
available







Advanced features are included to aid
remote programming






6
Dual reporting routes
SIA, CID, Domestic dialler reporting
SMS to mobiles with full text
Email reports direct from the dialer
Voice message reporting with addition of
voice module
IP reporting with addition of IP module
Compatible with most commercial modems
CLI Caller Line Identification
Tone bypass
Fax bypass
2400 baud upload and download
IP remote programming sessions with
addition of IP module
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Features & Benefits
New RS485 panel LAN
7

Commercial strength panel LAN less
susceptible to interference. It ensures
system integrity is maintained and
maximises customer security

Provides secure, encrypted transmission of
panel data

Anti substitution protection on modules
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Bosch Security Systems
Solution Common features

Common Wireless options across entire
range for ease of system upgrades with
minimal inventory *



All panels are Bosch DSRF compatible
All panels use the RF3212E receiver
Common hold down functions across all
panels increases user familiarity across
sites

Fire, panic and medical
* The above applies to Solution 880Ultima, Solution 16i,
Solution 16plus and Solution 64. The Solution 844 is not
wireless compatible.
8
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Features & Benefits
Solution Common features















9
Sensor watch
Area watch
Line fault detection
Dial and busy tone detection
Reports in CID, SIA, e-mail, SMS, domestic.
Redundant reporting
Dual reporting
32 digit Telco numbers
Call forward
CLI smart answer mode
All zones with programmable EOL and
pulse count
Burglary and fire report delay
Part mode entry timer
Dual entry timers
Auto arming and auto disarming











3 fully supervised and protected high current
outputs
1 change over 2amp relay
Optional Proximity reader built into code pad
All users with variable pin lengths 1-8 digits
Programmable zone, user, output, area text
In premise wireless compatible
Service reminder
User test reminder
Time executed functions, holiday schedules
and daylight savings
Senior watch
Swinger siren swinger dialler
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
10
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Solution 16i Modules
Night Arm Station







11
( CP050B)
Allows arming and disarming in part mode 1
and part mode providing no alarm has been
activated
Two button panic alarm
Built in sounder provides entry warning and
alarm alerts
LED indicators provide system and zone
status
Unobtrusive surface mount design
Ideally suited to residential installations
Lower price alternative to second code pad
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Solution 16i Modules
Relay output expander module





( CM710B)
4 x Form C relays
2 Amp contact rating at 24VDC
May be remotely located and controlled from
panel
Separate tamper input
Service code pad input
Refer to page 2 -8
of your manual
12
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Solution 16i Modules
8 / 16 Zone expansion module




( CM704B)
Provides 8 physical zone input terminations
per module
Allows zones to be remotely located away
from control panel to reduce cabling costs
Supports both LAN or external power
Separate tamper input
Refer to page 2 -7
of your manual
13
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Solution 16i Modules
Multi RF Receiver Interface





( CM195 )
3 x independent wireless receiver inputs
Support for multiple vendors RF
technologies
Allows increased wireless coverage and
reliability
Easy 3 wire connection to the control panel
Data received and processed indicators
Refer to page 2 -9
of your manual
14
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Features & Benefits
SolutionLink

Installation and maintenance can be taken a
step further with the use of our advanced
SolutionLink remote programming software













15
Built on MS SQL technology
Direct & remote link options
Live remote system diagnostics
Resistance, voltage, version, temperature
On line code pad simulator
Online database / panel synchronization
Summary & detail views
Real time interactive mode
PDF report formats
Account import/export and email
Comprehensive user authority levels
Windows Vista and Windows 7 Compatible
Full English text for all different sensors,
areas, users, time schedules. For example
Kitchen Dual Tech PIR (instead of Zone 1)
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Bosch Security Systems
Thank you
16
STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.