How to Configure Video Client

This presentation is intended to guide the installer step by step through
the Video Client installation.
Security Systems
1
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
DCN Next Gen
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Installing and Operating VDClient

Installing the Video Client Application on the DCN Control PC

Installing the Video Client Application on another PC.
Security Systems
2
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Installing VDClient on the DCN Control PC

Requirements:

DCNNG software already installed on the PC

LBB4184 (Video Display Software Module)

ClientSetup.exe
DCN Control PC
LBB4184
ClientSetup.exe
Security Systems
3
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 1
Install LBB4184
Security Systems
4
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
LBB4184
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 2
Install the ClientSetup.exe
Security Systems
5
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 3



Start the DCNNG software
Choose the desired
applications
Don’t forget to choose the
Video Display Application!
Start the applications
Security Systems
6
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 4

Start VDClient
VDClient is located in the programs list
in the Windows Start menu
Security Systems
7
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Menu F12



When starting the
application for the first
time you will come
automatically in the
configuration window.
Choose Program runs
on DCN Operator PC.
If needed adjust also
other settings and click
OK
Security Systems
8
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
End of Installing Video Display Software on a Server PC

End of this section.
Security Systems
9
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Installing VDClient on another PC

Requirements :
 DCNNG software already installed on the DCN Control PC
 LBB4184 (Video Display Software Module)
 ServerSetup.exe
 ClientSetup.exe
 TCP/IP protocol must have been installed at both PC’s
 Both PC’s must be in the same workgroup
DCN Control PC
LBB4184
ServerSetup.exe
TCP/IP
Security Systems
10
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
VDClientPC
ClientSetup.exe
Step 1
Set IP address of DCN Control PC
Security Systems
11
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 1

Set IP address of DCN Control PC
The IP addres of the DCN
Control PC must be set to
192.168.100.1
Security Systems
12
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 2

Set Subnet mask of DCN Control Control PC
The Subnet mask of the
DCN Control PC must be
set to 255.255.255.0
Security Systems
13
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 3
Set IP address of the client PC
Security Systems
14
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 3

Set IP address of the client PC
The IP addres of the DCN
Control PC must be set to
192.168.100.2
Security Systems
15
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 4

Set Subnet mask of the Client PC
The Subnet mask of the
other PC must be
set to 255.255.255.0
Security Systems
16
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Technical Tips


If more client PC’s have to be installed the same steps have to
made also for those PC’s.
Each client PC must have a unique IP address


IP address 192.168.100.x
( x = decimal value)
All PC’s must have the same Subnet mask 255.255.255.0
Security Systems
17
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 5
Install LBB4184
Security Systems
18
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
LBB4184
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 6
Install ServerSetup.exe on the DCN Control PC
Security Systems
19
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 7
Install ClientSetup.exe on the client PC
Security Systems
20
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 8



Start the DCNNG software
Choose the desired
applications
Don’t forget to choose the
Video Display Application!
Start the applications
Security Systems
21
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 9

Start VDServer on the DCN Control PC
VDServer is located in the programs list in the Windows Start menu
Security Systems
22
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Step 10 Start VDClient on the Client PC

VDClient is located in the programs list in the Windows Start menu
Security Systems
23
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Menu F12




When starting the
application for the first
time you will come
automatically in the
configuration window.
Choose Program runs
on an external PC.
Fill in the Network name
of the DCN PC
If needed adjust also
other settings and click
OK
Security Systems
24
ST/PRM3-EU | 02.Mar.06
DCNNG VC IO
| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
How to Configure Video Client