AC RGA Analyzers

Download Report

Transcript AC RGA Analyzers

AC RGA Analyzers
Multi-Purpose Gas Analysis
AC RGA Analyzers
1
Refinery Gas Analysis
• Control specifications and purity of
finished gas products: LPG, Ethylene,
Propylene and Butenes
• Control downstream processing
• Detect impurities of hydrocarbons, inert
gases or acid gases
• Calculate the market value of the gas:
Calorific Value
AC RGA Analyzers
2
AC Refinery Gas Analysis Range
Multi-Purpose % Analysis
Application
RGA Model 1012
RGA Model 1029
(UOP 539)
Fast RGA
(UOP 539)
RGA Model 1050
Components characterized by
concentration level
Hydrogen, oxygen, nitrogen, carbon
monoxide, carbon dioxide
hydrogen sulfide, carbonyl sulfide
C1-C4, C5+
Hydrogen, helium, oxygen, nitrogen,
carbon monoxide, carbon dioxide
hydrogen sulfide
C1-C5, C6+
Hydrogen, helium, oxygen, nitrogen,
carbon monoxide, carbon dioxide
hydrogen sulfide
C1-C5, C6+
Hydrogen, nitrogen, oxygen, carbon
dioxide
hydrogen sulfide, sulfur dioxide
C1-C2
AC RGA Analyzers
3
Methane
RGA
Ethane
RGA, LPG
Refinery Gas
RGA, LPG, Fixed Gases
Sat.
Gas
Plant
Propane
RGA, LPG
Butane
RGA, LPG
Naphtha
Reformulyzer ASTM D 6293
DHA,
SIMDIS ASTM D 3710
AC RGA Analyzers
4
Methane/H2
RGA,
Fixed Gases
Ethylene
Ethylene/Propylene,
STEP
Refinery Gas
RGA, LPG, Fixed Gases
Cracked
Gas
Plant
Propylene
Ethylene/Propylene,
STEP
Butenes/
Butadienes
Butenes/Butadienes
Naphtha
Reformulyzer ASTM D 6293
DHA,
SIMDIS ASTM D 3710
AC RGA Analyzers
5
AC RGA Features
• Linearity range of 0.1 - 100 volume %
• Response factors:
– Theoretical
– In house
– Calibrated
• Certified calibration gases
• Guaranteed analysis
• Reports in weight %, liquid volume %,
gas volume %
• Physical properties calculation
AC RGA Analyzers
6
Application Range
AC RGA 1029
The AC RGA 1029 system determines the
composition of most refinery gas streams
and reports:
• hydrogen
• helium
• inert gases: oxygen, nitrogen, carbon
monoxide, carbon dioxide
• H 2S
• C1-C5 hydrocarbons
AC RGA Analyzers
7
System Description
AC RGA 1029
•
•
•
•
Agilent 6890 Series gas chromatograph
Electronic Pneumatics Control (EPC)
Packed GC columns
2 Thermal Conductivity Detectors (TCD)
AC RGA Analyzers
8
Flow Diagram AC RGA 1029
Column 3
Front Inlet
Column 4
Column 2
PTA
Sample in
2
on/off
1
3
9
4
8
V1
5
6
1
1
10
2
6
2
6
3
5
3
5
7
4
4
PTA
Column 5
2
1
9
4
8
5
6
7
S-restr.
TCD
Back Detector
10
3
Sample out
Front Detector
Column 1
Aux 4 (N 2)
TCD
S-restr.
Aux 3 (N 2)
Backflush Vent
AC RGA Analyzers
9
AC RGA 1029
1. Hydrogen
2. n-Hexane
3. Hydrogen
4. Propane
5. Acetylene
6. Propylene
7. Hydrogen Sulfide
8. Isobutane
9. Propadiene
10. n-Butane
11. 1-Butene
12. Isobutene
13. trans-2-Butene
14. cis-2-Butene
0 Minutes
10
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
1,3-Buta diene
Isopentane
n-Pentane
1-Pentene
trans-2-Pentene
c is-2-Pentene
2-methyl-2-Butene
Carbon Dioxid e
Ethylene
Ethane
Argon/Oxyg en
Nitrog en
Methane
Carbon Monoxide
20
AC RGA Analyzers
30
40
10
Application Range AC Fast RGA
The AC Fast RGA system determines the
composition of most refinery gas streams
and reports:
• hydrogen
• helium
• inert gases: oxygen, nitrogen, carbon
monoxide, carbon dioxide
• H 2S
• C1-C5 hydrocarbons
AC RGA Analyzers
11
System Description AC Fast RGA
•
•
•
•
•
Agilent 6890 Series gas chromatograph
Electronic Pneumatics Control (EPC)
Packed GC columns
Thermal Conductivity Detector (TCD)
Flame Ionization Detector (FID)
AC RGA Analyzers
12
Flow Diagram AC Fast RGA
0.25 mL
309
Front Inlet H2
Column 1
2
1
10
3
4
FID
8
5
6
7
S-restrictor
Column 2
Column 5
210
PTA
9
on/off
0.50 mL
N 2 (Aux 5)
2
1
10
3
9
4
8
5
6
7
Vent He
2
1
10
3
Vent He
9
4
Ref He
Vent N 2
Vent N 2
8
5
6
PTA
7
TCD
225
S-restrictor
0.50 mL
Sample out
2
301
Ref. N 2
10
3
9
4
He (Aux 3)
Column 6
Column 3
1
8
5
6
7
Vent
1
2
6
3
5
4
He (Aux 4)
Column 4
AC RGA Analyzers
13
AC Fast RGA Model
1
7
2
3
8
4
6
5
0
1. Hydrogen
2. Carbon Dioxide
3. Ethylene
4. Ethane
5. Acetylene
6. Oxygen
7. Nitrogen
8. Methane
9. Carbon Monoxide
10
AC RGA Analyzers
minutes
9
20
14
AC Fast RGA Model
4
1. C6+
2. Methane
3. Ethane/Ethylene
4. Propane
5. Acetylene
6. Propylene
7. Cyclopropane
8. Isobutane
9. Propadiene
3
8
2
1
10. n-Butane
11. 1-Butene
12. Isobutene
13. trans-2-Butene
14. cis-2-Butene
15. 1,3-Butadiene
16. Isopentane
17 n-Pentane
10
6
13
15
11
5
12
9
14
16
7
0
5
10
AC RGA Analyzers
minutes
15
17
20
15