下載/瀏覽Download

Download Report

Transcript 下載/瀏覽Download

Agilent 35670A Operator’s Guide
Different types of measurement.
• Rotating Machinery
• Structures(FRF)
• Sound/Acoustics
• Spectra and Networks
• Control Systems
1
Copyright 2010 ITRI工業技術研究院
• HP 35670A (Front Panel)
2
Copyright 2010 ITRI工業技術研究院
Spectrum Analyzer
• Initialize the analyzer- [Preset]
• [Inst Mode]-FFT Analysis, channels
• [Meas Data] [Active Trace]- selecting which type of data you
want to display ,PWR SPEC,LIN SPEC,TIME CHANNEL(1),
• [Freq] –span measurements, resolution, record length
• [Input] – Measurement parameters affect the way the analyzer
takes input data,
RANGE,FRONT END CH1 SET UP, XDCR UNIT CH1 SET UP
grounded/floating input
coupling ac/dc
anti-alias filter on/off
autoranging on/off
A-weight filter on/off
ICP power supply on/off
Sensitivity on/off
3
Copyright 2010 ITRI工業技術研究院
• [Window]- Selecting a windowing function, HANN, FLAT TOP,
UNIFORM,FORCE EXPO, FORCE EXPO SETUP
• [Trigger]- Selecting a triggering function, Free Run Trigger,
External Trigger, Channel Trigger, Source Trigger, GPIB Trigger
• [Avg]- average on/off, number averages, average type,fast avg
on/off, update rate, repeat on/off, overlap %, overload rej on/off,
average preview off/manual/time
• [Source]-source on/off, level, dc offset,
4
Copyright 2010 ITRI工業技術研究院
• [Trace Coord]-Linear Magnitude, Log Magnitude, db Magnitude,
phase, wrapped phase, x units,Y units
• [Analysis]- define function, define constant, data edit, curve fit,
synthsis
• [Scale]- autoscale on/off, match Y scale, axes scale markers
• [Disp Format]- single, upper/lower, front/back, upper/big lower,
quad, measurement state, waterfall setup
• [Marker]- marker on/off, coupled on/off, peak trk on/off
• [Marker Fctn]- harmonic marker, band marker, sideband marker ,
freq & damping
5
Copyright 2010 ITRI工業技術研究院
Measuring Rotating Machinery
1.
•
•
•
Initialize the analyzer.
Press [Preset] [DO PRESET].
Press [Inst Mode] [FFT ANALYSIS].
Press [CHANNELS 1 2] (or [CHANNELS 1 2 4]) Press [Meas Data], then
press [CHANNEL 1 2] (or [CHANNEL 1 2 3 4]) to highlight the channel
whose transducer you will calibrate.
• Press [PWR SPEC CHANNEL x].
2. Match the active trace’s display unit to the calibrator’s output unit.
• Press [Input], then press [CHANNEL 1 2] (or [CHANNEL 1 2 3 4]) to
highlight the channel whose transducer you will calibrate.
• Press [XDCR UNIT CHx SETUP] [XDCR UNIT LABEL], then press the
softkey corresponding to your calibrator’s output unit.
• Press [Input] [XDCR UNIT CHx SETUP], then press [XDCR UNIT ON OFF]
to highlight ON.
• Press [Trace Coord] [Y UNITS] [EU].
• Press [AMPLITUDE PK PP RMS].
6
Copyright 2010 ITRI工業技術研究院
3. Connect the transducer’s output cable to the analyzer as described at the
beginning of this chapter, then secure the transducer to the calibrator.
4. Specify the measurement parameters.
• Press [Freq] [SPAN], then press the down-arrow key if you want to reduce
the frequency span.
• Press [Window] [FLAT TOP] to maximize amplitude accuracy.
5. Press [Scale], then press [AUTOSCALE ON OFF] to highlight ON.
6. Turn on the calibrator, then press [Start].
7. After the display has been updated at least once, move the marker to the
calibrator’s output frequency and enter calibrator’s output amplitude.
8. Press [Marker] [MARKER TO PEAK].
• Press [Input] [XDCR UNIT CHx SETUP] [CAL VALUE AT MARKER], then
type the calibrator’s specified output amplitude and press [ENTER].
7
Copyright 2010 ITRI工業技術研究院
Measuring Structures(FRF)
8
Copyright 2010 ITRI工業技術研究院
9
Copyright 2010 ITRI工業技術研究院
1.
•
•
•
2.
3.
•
•
•
•
•
•
•
•
•
•
•
•
Initialize the analyzer.
Press [Preset] [DO PRESET].
Press [Active Trace] [A B].
Press [Meas Data] [FREQ RESP 2/1].
Connect the device-under-test (DUT) as shown in the illustration below.
Specify the measurement parameters.
Press [Freq] [START] <number> <unit>, then press [STOP] <number> <unit>.
Press [Input].
Press [CHANNEL 1 2 3 4] to highlight 1.
Press [CHANNEL 1 RANGE] <number> <unit>.
Press [CHANNEL 1 2 3 4] to highlight 2.
Press [CHANNEL 2 RANGE] <number> <unit>.
Press [Window] [FORCE EXPO].
Press [FORC EXPO SETUP].
Press [CHANNEL 1 FORC EXPO] to highlight FORC.
Press [FORCE WIDTH] <number> <unit>.
Press [CHANNEL 2 FORC EXPO] to highlight EXPO.
Press [EXPO DECAY] <number> <unit>.
10
Copyright 2010 ITRI工業技術研究院
4. Specify the triggering and averaging parameters.
•
•
•
•
•
•
5.
•
•
•
•
•
6.
•
•
Press [Trigger] [CHANNEL 1 2 3 4] to highlight 1.
Press [TRIGGER SETUP] [CHANNEL LEVEL] <number> [PERCENT %]
Press [CHANNEL 1 DELAY] [+/-] <number> <unit>.
Press [CHANNEL 1 2 3 4] to highlight 2.
Press [CHANNEL 2 DELAY] [+/-] <number> <unit>.
Press [Avg], then press [AVERAGE ON OFF] to highlight ON.
Configure the display.
Press [Trace Coord] [X-AXIS LIN LOG] to highlight LIN.
Press [Active Trace] [B].
Press [Trace Coord] [PHASE].
Press [Active Trace] [A B].
Press [Scale], then press[AUTOSCALE ON OFF] to highlight ON.
Measure the DUT.
Press [Start].
Slowly tap the device 10 times with the impact hammer at or near the
accelerometer.
11
Copyright 2010 ITRI工業技術研究院