Kemper Roof Pres.ppt

Download Report

Transcript Kemper Roof Pres.ppt

The Kemper Arena Roof Collapse
Group 5
Introduction





History
What happened
Technical factors
Human factors
Summary
History




Built in 1973 as a
basketball arena
Capacity of 17,000
Contemporay
design
AIA conference on
day preceeding
disaster
What happened





June 1979 roof collapse
70 mph storm
Pooling of water on roof
4000 m2 of roof collapsed
Rapid increase in air pressure
Technical factors





Steel trusses
supported RC roof
4 A490 bolts
Bolts subjected to
24,000 oscillations
Caused metal to
fatigue
Bolts failed at 1/3
capacity
Technical factors






Temporary reservoir on roof
Drainage inadequate
8 10” drains
“Ponding” effect caused instability
Bolts failed in one hanger
Disproportionate collapse
Technical factors
Human factors

Poor bolt selection



Inadequate drainage design



High strength, low ductility
Neglected metal fatigue
City codes required 55 drains
One in 10 year storm
Insufficient hangers
Summary

Reasons for collapse




Bolt failure
Ponding effect
Disproportionate collapse
Lessons to be learned



Dynamic loading on bolts
Building standards
Better load distribution