SUN StorEdge Library Installation &
Operating Manual(ADIC OEM)
Dae suk, Kim([email protected])
Storage Business Dept. 1 Team
LOIT Co., Ltd
SUN StorEdge L8 Tape Library

OEM of ADIC FastStor

Supported Drive Type

LVD SCSI Only : LTO1, LTO2, SDLT320

21 DLT or 25 LTO slots

Max Capacity : 1.6 TB

Max # of Drives : 1

Barcode Label : Optional

Desttop and Rackmount Configurations

2U rack height

User friendly LCD and 4 button keypad

Software Bundle optional

Optional Barcode Reader

80,000 hours MTBF
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Feature


Multi-function Operator Panel

4개의 LED, 4개의 button, 16 character 2line LCD로 구성

Operator Panel은 autoloader 상태 모니터링과 모든 기능을 컨트롤 가능
Cleaning Cartridge


Cartridge Pre-Check


Autoloader의 power를 켤때마다 카트리지 스토리지, 드라이브를 스캔하고 체크가
끝난 후 카트리지 위치를 LCD에 표시
Built-in Diagnostics


Cleaning Cartridge가 슬롯을 점유하고 있지 않아도 필요시 수동으로 Operator Panel을
통해 Cleaning Cartridge를 import시켜 clean가능
Diagnostic firmware를 포함하고 있어 head cleaning이 필요한 경우 메시지를 보내고, 진
단 결과나 드라이브 운영 상태를 레포팅
Rackmount Ready

2U Rack Space로 rack mount가능
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Hardware 구성도
Terminator
X6758A(Ultra3 HBA)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Library Setup Order

1. Host에 Scsi Cable연결 & Library Power On (11번 Slide참조)

2. Library Inventory 종료 후 Media Import (11번 Slide 참조)

3. OS상에서의 St Driver & Ultra3 Patch확인, Patch(6번Slide 참조)
4. Tape Device생성

가. OK mode : OK> boot –r

나. MultiUser Mode : # reboot -- -r or #drvconfig;tapes;(Online Rebuild)




5. OS상에서의 Device생성 확인
가. #luxadm inq /dev/rmt/테잎순서 or
# /dev/rmt/밑에 device생성되었는지 확인
나. Netbackup or NetWorker상에서 changer & tape확인
#sgscan –v changer;sgscan –v tape (Netbackup Utility)
#inquire (Networker Utility)
6. Robot Test
가. #/usr/openv/volmgr/bin/robtest로 미디어 제어확인
ex) init , test_ready etc …
2004 Loit Co., Ltd Storage Business Dept. 1 Team
ST Driver Patch Required


Scsi Type에 맞는 HBA Card장착

Ultra3 SCSI(LVD) 160m/s : X6758A

Ultra2 SCSI(LVD) 80m/s : X2222A

Ultra Differential(HVD) 40m/s : X6541A

Ultra Differential Fast/Wide(HVD) 40m/s : X6749A(EOL)
Device Server쪽에 current version st.conf 등록


Version별 Patch Name
 Solaris 2.6 : 105847

Solaris 7 : 107460

Solaris 8 : 108725

Solaris 9 : 13277
LVD tape drive는 Solaris 7, 이하 버전 지원못함
Device Server쪽에 Ultra3 patch(Ultra 3 Scsi일 경우)


SUNWqus.tar.Z [66K]
SUNWqusx.tar.Z [68K]

SUNWqusu.tar.z [3K]
SUNWqusux.tar.Z [4K]
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Performance Tunning

HBA의 최대 속도와 Library의 속도 확인

X6758A(Ultra3 SCSI)의 경우
HBA속도 : 160m/s(Dual Port), 한 개 Port는 Maximun 80m/s지원



LTO2 Drive(초당 30m/s)지원
L8 Library의 경우 Robot과 Drive가 같은 Port를 사용하므로 X6758 한 개 Port만으로도
드라이브 속도를 충분히 소화할수 있음
Drive가 여러 개인 경우 / Robot Scsi Port가 분리된 경우(L25/L100/L180)

HBA의 한 개 Port의 Maximun Speed와 드라이브 속도 체크

Ex) Drive가 3개인 경우

Library쪽 port는 Maximum 4ea(Robot 1ea / Drive 3ea)

Robot 3ea를 Jumping할 경우 90m/s를 지원해야 함



따라서 X6758의 경우 80m/s밖에 지원이 안되므로 나머지 port를 사용하여
Library쪽에서두개의 Line을 사용하는 것이 바람직함
(Robot+Drive1ea = 1개 channel / Drvie2ea = 1개 channel)
Robot에 연결된 Scsi Fail시 Drive작동이 전혀 불가하므로 가능하면 Scsi Cable을 분리
하여 잉여 드라이브를 사용 권장
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Normal Operation

Home Screen, Drive Empty


카트리지 인벤토리 완료후 slot number별로 표
시

Empty Slot은 dash(-)로 표시

! -> invaild cartridge type or media-related error인 경우

불량 media는 export 시킴
Drive loaded



Tape drive가 카트리지를 로드하게 되면 Drive
loaded라고 Top line에 표시
현재 드라이브에 로드된 카트리지는 black
block으로 표시
카트리지의 load, unload, import, export시 black
block표시
2004 Loit Co., Ltd Storage Business Dept. 1 Team
LED & Operator Panel Control

LED Indicators

Ready/Activity(GREEN)

Power-On시 점등, 오토로더 activity시 Blinking
Cleaning Drive(Amber)

Tape drive cleaning이 필요할시 점등
Media Attention(Amber)

Tape fault시 점등, 해당 카트리지 export 요망
Error(Red)





Unrecoverable tape drive, autoloader error발생시 점등

해당 Message LCD에 Display
Control Buttons

Cancel : 현재 메뉴 옵션을 취소하고 전 메뉴 레벨이나 Home screen 복귀

Previous : 현재 디스플레이된 메뉴 전 아이템, Value선택

Next : 현재 디스플레이된 메뉴 다음 아이템, Value선택

Enter : 현재 메뉴를 실행하거나 LCD Pannel에 디스플레이된 현재 옵션 실행
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Operator Panel Menu Structure
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Power up & Importing Cartridges

Power ON


펜슬로 power-switch의 left Side를
누름
Importing / Exporting Cartridges









주의 : DATA Backup도중 media import or export시 backup Failure
Write-Protected 상태 점검
Home Screen or main menu에서 Press + or – Until Command appears
Command 커서에서 Enter
Press + or – Until Import/Export appears / Enter Select
Press + or – Until desired slot number appears / Enter Select
Insert Cartridge Slot이 LCD에 Display되면 open된 Mail Slot에 Media 삽입
Importing Cartridge가 완료되면 Press Cancel
LCD Panel에 import/Export한 카트리지 확인
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Loading & Unloading Cartridges


Loading Cartridges

Home Screen or main menu에서 Press + or – Until Command appears

Command 커서에서 Enter

Press + or – Until Load Cartridges appears / Enter Select

Press + or – Until desired slot number appears / Enter Select

카트리지가 로딩되는도중 LCD 스크린에 status message 확인

Operation완료 후 Drive Stopped message appears
Unloading Cartridges

Home Screen or main menu에서 Press + or – Until Command appears

Command 커서에서 Enter

Press + or – Until UnLoad Cartridges appears / Enter Select

Press + or – Until desired slot number appears / Enter Select

카트리지가 언로딩되는도중 LCD 스크린에 status message 확인

Operation완료 후 Drive Empty message appears
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Cleaning the Tape Drive

Clean Drive LED가 점등되면 Clean Required

Cleaning Time은 LED Blinking되는 동안 수초, 수분간 cleaning

수동으로 Operator Panel Command로 Clean할 경우에는 Command -> Clean Drive Select

Home Screen or main menu에서 Press + or – Until Command appears

Command 커서에서 Enter

Press + or – Until Clean Drive appears / Press Enter

만약, 빈 Slot이 없으면 LCD Screen Displays “No slot free for transfer”
한 개 카트리지 임시로 export시킨 후 Retry

Insert Clean Cartridges -> Cleaning

만약, import시킨 카트리지가 클리닝 카트리지가 아니면 LCD Diplays
“Invaild Tape and the cartridge will be exported”

클리닝 완료시, Clean Drive LED turn Off 됨.

클리닝 하기 위해 빼낸 기존 카트리지 import
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Troubleshooting and Diagnostics

Installation Issues

Install시 발생하는 문제들은 대부분 SCSI Bus Configuration, Application software configuration
error가 대부분으로 application software install후에 autoloader와 통신상에 문제가 있을때 다
음과 같은 것을 확인

SCSI ID : autoloader는 Drive용으로 1개의 scsi ID / Robot을 위한 scsi ID 1개로 기존 scsi ID와의 충
돌 여부를 확인

SCSI Cabling : Scsi Type과 Length 확인

Termination : SE/LVD등 적합한 Terminator 확인

Backup Application Installation : backup S/W 지원하는 module 확인

Device Driver Installation : OS level에서 지원되는 H/W Driver Install확인
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Troubleshooting Matrix

Troubleshooting Table





Autoloader does not power on : power cord연결 상태 확인 / Front panel의 power switch On position인지
확인 / Power outlet상태 확인 / Power cord 교체
No display messages appear : power cord연결 상태 확인 / autoloader firmware download
Cannot write to or read from tape : 카트리지 write enabled switch확인 / Tape Drive에서 호환 가능한
media type인지 확인 / 다른 Backup Software에서 backup받은 format인지 확인하여 erase, format,
labeling / Backup Software의 보관주기 영향으로 overwrite protection scheme 확인
Changed drive SCSI ID, but the host server does not recognize the new ID : Host에 연결된 다른 scsi장비와
의 충돌 문제, Narrow(50-pin) Type일 경우 0번에서 7번까지의 ID만 가능 / Reboot the host Server
The autoloader is not efficiently backing up data : Host computer에서의 network bandwidth 확인 / 네트웍
을 통한 backup이라면 local backup과 속도비교 / Clean Drive / 노후된 카트리지의 경우 bad spot
으로 인해 tape require retry가 많이 발생할수 있으므로 카트리지 교환 / 파일 싸이즈 확인(작
은 싸이즈의 많은수의 파일은 백업에 영향) / Backup application의 block Size는 최소한 32K이상 /
각각의 Backup application 문서의 Tunning Guide참조
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Removing Stuck Cartridges

Power Fail등으로 인해 Media를 export시킬수 없는 상태일
경우

Power Switch & Scsi Cable분리

Screw driver로 뒷부분 분리

Top cover lift & 분리

Carrier마다 cartridge lever를 당겨서 carrier에서 media 분리


Carrier재장착후 belt를 앞뒤로 돌려서 제대로 install되었는
지 확인
Top cover Replace, reinstall Screw / mounting
2004 Loit Co., Ltd Storage Business Dept. 1 Team
View Event Logs / Firmware Ver.


View Event Logs

Home Screen or main menu에서 Press + or – Until Information appears

Information 커서에서 Enter

Press + or – Until View Enent Log appears / Enter Select

The most recent log is Number 0

Press CANCEL
Firmware Version

Home Screen or main menu에서 Press + or – Until Information appears

Information 커서에서 Enter

Press + or – Until Firmware Rev appears / Enter Select


3개의 Firmware 확인 : Ultrium Tape Drive Controller, Autoloader SCSI Controller, Autoloader Robotics