Introducing Belliss USA Inc. BELLISS INDIA LIMITED A SUBSIDIARY OF

Download Report

Transcript Introducing Belliss USA Inc. BELLISS INDIA LIMITED A SUBSIDIARY OF

Introducing
Belliss USA Inc.
A SUBSIDIARY OF
A LEADING INTERNATIONAL
STEAM TURBINE MANUFACTURER
BELLISS INDIA LIMITED
1
Belliss USA Inc.
Steam
Turbines
International
Sourcing
Component Eng/Dftg
Manufacturing Services
Installation
Project
Field
Management
Services
2
Belliss India Limited









Incorporated in 1960 - OVER 48 YEARS
Originally turbines built under license from
W.H. ALLEN (UK)
Previously a division of Rolls Royce
Product range -100KW TO 20,000KW
0ver 2,500 turbines shipped to date
55,000 square feet of manufacturing and
test space
Turbines consistent with API/ISO standards
Units installed in 11 different industries
Units operating in 15 different countries
3
Belliss USA Inc.
Bhadreshar Works
4
Belliss USA Inc.
Worldwide Installations
We have not only made our mark in India but in other countries such as…







AUSTRALIA
BANGLADESH
FIJI ISLAND
NEPAL
NEW ZEALAND
NIGERIA
SINGAPORE







SPAIN
SOUTH AFRICA
TANZANIA
UGANDA
VIETNAM
PHILIPINES
UGANDA
The first Indian company to export to South Africa and Australia
5
Belliss USA Inc.
Technical Strength





Technology company with 250 engineers
designing, manufacturing and servicing steam
turbines
Partnering with USA design engineering
company with extensive steam turbine design
and packaging experience
Products consistent with international
standards including, NEMA, ISO and API
Design and performance tools used for the
design of thousands of turbines by Belliss and
W.H. Allen
Development tools including 3-D design and
modeling software
6
Belliss USA Inc.
Infrastructure

Three (3) Manufacturing, assembly and test facilities

Bucket and rotor shop with multi-axis NC machining

In house fabrication and machining of diaphragms

Fully computerized engineering and design facility

Proven analysis software and design tools

Project execution team

Over 50 Field service engineers on staff

Steam testing facility

In house parts warehouse

Complete lubrication system design and testing

Digital and mechanical controls expertise including
system integration and testing
7
Belliss USA Inc.
Bio Mass – Turbine Generator Sets for Uruguay
Two fundamental choices for steam turbine exhaust:


Non Condensing-Exhaust above atmospheric pressure

Pros: Steam at lower pressures can be used in food processing,
heating, air conditioning, process or for other small turbine
drivers.

Cons: Since exhaust pressure is high, depending on the
pressure level, it will require 2 to 3 times as much steam to make
the same output.

Potentially 100% Make up water will have to be treated.
Condensing Turbine –Vacuum or sub-atmospheric

Pros: Due to the higher available energy, more power will be
generated for the available steam.

Cons: Requires a condenser, cooling towers and a larger turbine

Only choice if no steam host available
8
Belliss USA Inc.
Bio Mass – Turbine Generator Sets for Uruguay
NON CONDENSING (SNC)
STRAIGHT CONDENSING (SC)
45 Kg/cm²g/@450 ºC
Turbine
1.5-5 Kg/cm²g
Gear
Generator
Condenser
Belliss USA Inc.
Bio Mass – Turbine Generator Sets for Uruguay

Belliss India Limited has experience in both
Condensing and Non Condensing turbines in this
size range.

Geared turbine generator sets are the norm for this
size range to take advantage of higher speed
turbine designs

If High power sales is key, a condensing turbine is
best
If Process steam is more valuable, a non
condensing turbine may be best

10
Belliss USA Inc.
Bio Mass – Turbine Generator Sets for Uruguay
Required steam data:
(If steam flow is known, output will be calculated)
Note: Every turbine/generator set is custom designed
Turbine
Generator
Inlet Steam
Inlet Flow
Exhaust
Speed
Kwe
Conditions
kg/hr
Conditions
Normal
450
___ Kg/cm² g/ ____°C
___Kg/cm² ABS
Rated
495
___ Kg/cm² g/ ____°C
___Kg/cm² ABS
Inlet steam conditions:
(The higher pressure & temperature, the greater the available energy
will be but, the cost of hardware will likely increase as will the plant
piping)
11
Belliss USA Inc.
Single Stage Turbine
MODEL SS4A
Max Output
• 700 HP
Rated Speed
• 7,000 RPM
Max Inlet Pressure • 640 Psig
Max Inlet Temp
• 842 °Ftt
Max Exhaust
• 80 Psig
Number of Hand Valves: 2
Standards Followed BS/NEMA/API
Application: Mechanical Drives
& Power Gen
12
Belliss USA Inc.
Single Stage Turbine
MODEL SS6A
Max Output
• 1,200 HP
Rated Speed
• 6,000 RPM
Max Inlet Pressure
• 640 Psig
Max Inlet Temp
• 842 °Ftt
Max Exhaust Pressure • 80 Psig
S6H : 1,200 HP @ 256 Psig Exhaust
Number of Hand Valves: 2
Standards Followed: BS/NEMA/API
Application: Mech. Drives & Power Gen
Typical Scope









Turbine
Gear
Generator
Oil System
Turbine Controls
Generator Excitation and Protection
Base mounted turbine, gear and generator
Steam testing
Condenser when required
13
Belliss USA Inc.
After Market Support

Large spare parts inventory at Kolkata
factory

Fifty (50) Experienced service
engineers trained and ready for
deployment world wide

Association with USA Engineering and
service companies
14
Belliss USA Inc.
Summary Belliss Turbines









Incorporated in 1960
Heritage from W. H ALLEN/ ROLLS
ROYCE
Over 1200 single stage turbines in service
Over 1300 multi stage turbines in service
Highly standardized frame sizing designs
Complete packaging including controls and
oil system
Detail design and analysis on every unit
ISO 9001:2000 Certified
Material certification and inspection by
LLOYDS
15
Belliss USA Inc.