IDEM RFID non-contact switch

Download Report

Transcript IDEM RFID non-contact switch

SECTION 13
LPF & SPF - RFID CODED NON CONTACT SAFETY SWITCHES
RFID Coded Non Contact Types: LPF-RFID & SPF-RFID
FEATURES & APPLICATION:
IDEM’s LPF-RFID and SPF-RFID Non Contact Coded switches have been developed to provide and maintain a high level of functional safety whilst
providing a very high anti-tamper coded activation.
Coding is achieved by using magnetic and radio frequency techniques, both principles need to be satisfied for the switch to operate safely.
They will connect to most popular standard Safety Relays to achieve up to PLe to ISO13849-1.
They are offered in high specification plastic housings and can be used in almost any environments including areas where high pressure cleaning is
a requirement following contamination from foreign particles.
Both switches have IP69K ingress protection and are suitable for CIP and SIP processes.
The typical sensing distance “on” is 14mm with wide tolerance to guard misalignment after setting.
The RFID sensing provides a tamper resistant operation when the actuator is in the sensing range of the switch.
LPF-RFID and SPF-RFID switches are both available in two types either coded by series or uniquely coded.
TYPE 1: LPF-M-RFID or SPF-M-RFID
Master Code - by series (any actuator will operate any switch) - used when unique door activation is not required, but the benefit of
RFID makes it virtually impossible to be overridden or by-passed by simple means.
TYPE 2: LPF-U-RFID or SPF-U-RFID
Unique Code - 32,000,000 unique codes. These switches are factory set and used when unique activation is required in areas where
there are many interlocked doors and security of individual areas is required.
IP69K
LPF-RFID-U (Uniquely Coded)
LPF-RFID-M (Master Coded by Series)
IP69K
SPF-RFID-U (Uniquely Coded)
SPF-RFID-M (Master Coded by Series)
MAIN USER BENEFITS:
● RFID provides a high degree of anti-tamper thereby making it virtually impossible to be overridden.
● Unique RFID or series coding RFID available - this is dependent upon the user’s risk assessment.
● Able to connect to most popular Safety Relays to achieve up to PLe ISO13849-1.
● Connect up to 20 switches in series.
● Ability to connect other switches and E-Stops in series.
www.idemsafety.com
FUNCTIONAL SPECIFICATION:
124
High Functional Safety to ISO13849-1.
Connects to most Safety Relays to maintain PLe.
RFID Coded actuation to provide high tamper proof interlock security on Guard Doors.
Diagnostic LED: LED Green - Indication of Safety Circuits Closed.
2NC Safety Outputs short circuit protected.
1NO Auxiliary Output for indication of door open.
No moving parts - high switch life and resistance to shock and vibration.
M12 Male 8-way Quick Connector versions available (Flying Lead 250mm (10”)).
For all IDEM switches the normally closed (NC) circuits are
closed when the guard is closed and the actuator is present.
PRINCIPLE:
Quick Connect M12
versions fitted with
250mm (10”) cable
Single switch connected to an SCR-21-i or SCR-31-i to give Dual Channel Monitoring with Manual Start.
Safety Classification and Reliability Data:
Minimum switched current:
Dielectric Withstand:
Insulation Resistance:
Recommended setting gap:
Switching Distance:
ISO14119 EN60947-5-3 EN60204-1 ISO13849-1
EN62061 UL508
10V.dc 1mA
250V.ac
100 Mohms
5mm
Sao 10mm Close
Sar 20mm Open
Tolerance to Misalignment: 5mm in any direction from 5mm setting gap
Switching frequency: 1.0 Hz maximum
Approach speed: 200mm/m to 1000mm/s
Body material: Polyester
Temperature Range: -25/80C
Enclosure Protection: IP67
Cable Type: PVC 6 or 8 core 6mm OD Conductors 0.25mm2
Mounting Bolts: 2 x M4 Tightening torque 1.0 Nm
Mounting Position: Any
Characteristic Data according to IEC62061 (used as a sub system):
Safety Integrity Level SIL3
PFH (1/h) 4.77E-10 Corresponds to 4.8% of SIL3
PFD 4.18E-05 Corresponds to 4.2% of SIL3
Proof Test Interval T1 20a
Characteristic Data according to EN ISO13849-1:
Performance Level e If both channels are used in combination with a
SIL3/PLe control device
Category Cat4
MTTFd 1100a
Diagnostic Coverage DC 99% (high)
Number of operating days per year: dop = 365d
Number of operating hours per day: hop = 24h
B10d not mechanical parts implemented
When the product is used deviant from these assumptions (different load, operating
frequency, etc.) the values have to be adjusted accordingly.
OPERATING DIRECTIONS:
Quick Connect QC
M12 8 Way Male Plug
Pin view from Switch
8
5
4
6
7
Flying
Lead
Colour
Orange
Brown
Yellow
Green
Black
1
2
3
White
Red
Blue
Circuit
(Actuator Present)
Auxiliary NO
Auxiliary NO
Safety NC2
Safety NC2
Safety NC1
Safety NC1
Supply +24Vdc
Supply 0Vdc
Output Types
Solid State
200mA Max. 24Vdc
200mA Max. 24Vdc
200mA Max. 24Vdc
Supply 24Vdc
+/- 10%
SALES
NUMBER
404001
404002
404003
404004
UNIQUELY CODED
(every switch unique activation)
LPF-U-RFID
LPF-U-RFID
LPF-U-RFID
LPF-U-RFID
CABLE
LENGTH
2M
5M
10M
QC-M12
SALES
NUMBER
405001
405002
405003
405004
UNIQUELY CODED
(every switch unique activation)
SPF-U-RFID
SPF-U-RFID
SPF-U-RFID
SPF-U-RFID
CABLE
LENGTH
2M
5M
10M
QC-M12
SALES
NUMBER
404101
404102
404103
404104
404201
MASTER CODED
(same code every switch)
LPF-M-RFID
LPF-M-RFID
LPF-M-RFID
LPF-M-RFID
Replacement Actuator Master Coded
CABLE
LENGTH
2M
5M
10M
QC-M12
SALES
NUMBER
405101
405102
405103
405104
405201
MASTER CODED
(same code every switch)
SPF-M-RFID
SPF-M-RFID
SPF-M-RFID
SPF-M-RFID
Replacement Actuator Master Coded
CABLE
LENGTH
2M
5M
10M
QC-M12
For all IDEM switches the normally closed (NC) circuits are
closed when the guard is closed and the actuator is present.
140101
140102
Female QC Lead
Female QC Lead
M12 Female 5m. 8 way
M12 Female 10m. 8 way
www.idemsafety.com
Standards:
SECTION 13
CONNECTION EXAMPLE:
LPF & SPF - RFID CODED NON CONTACT SAFETY SWITCHES
RFID Coded Non Contact Types: LPF-RFID & SPF-RFID
125
SECTION 14
RAMZSense LPZ - RFID CODED NON CONTACT WITH AUTO TEST
RFID Coded Non Contact with Auto Test Type: RAMZSense
FEATURES & APPLICATION:
IDEM’s RAMZSense Intelligent Series Non Contact Coded switch has been developed to provide and maintain a high level of functional safety whilst
providing tamper proof RFID coded activation.
They will connect to most popular standard Safety Relays to maintain a PLe Safety Level even with switches connected in series.
They are offered in high specification plastic housings and can be used in almost any environment including areas where high pressure cleaning
following contamination from foreign particles is a requirement.
They have IP69K ingress protection and are suitable for CIP and SIP processes.
They have easy to understand LED diagnostic functions and provide auxiliary outputs for extra diagnostic signals to PLCs or computers.
The typical sensing distance “ON” is 12mm with wide tolerance to guard misalignment after setting.
Coding is achieved by using magnetic and radio frequency techniques, both principles need to be satisfied for the switch to operate safely.
The RFID sensing provides a tamper resistant operation when the actuator is in the sensing range of the switch.
The RAMZSense switches are available in 2 Versions:
VERSION 1: Type M Master code - by series (any actuator will operate any switch) used when unique door activation is not required, but the
benefit of RFID makes it virtually impossible to be overridden or by-passed by simple means.
VERSION 2: Type U 32,000,000 Unique codes - these switches are factory set and used when unique activation is required in areas where
there are many interlocked doors and security of individual areas is required.
IP69K
SAFETY RELIABILITY:
The RAMZSense switches employ two microprocessors and they use IDEM’s intelligent system to check all switches at each safety demand.
Safety Reliability up to ISO13849-1 PLe.
MAIN USER BENEFITS:
● RFID provides a high degree of anti-tamper - virtually impossible to override.
● Unique RFID or series coding RFID available - depending upon user's risk assessment.
● Maintains PLe by employing IDEM's technique at each safety demand.
● Connect up to 20 switches in series.
www.idemsafety.com
● Able to connect to most popular Safety Relays without the need for special controllers.
126
● Ability to connect to other switches and Emergency Stops in series.
FUNCTIONAL SPECIFICATION:
High Functional Safety to ISO13849-1 - connects to most Safety Relays to maintain PLe.
RFID Coded actuation to provide high tamper proof interlock security on Guard Doors.
Safety Outputs short circuit protected.
One Auxiliary circuit for indication of door open.
No moving parts - high switch life and resistance to shock and vibration.
M12 Male 8-way Quick Connector versions available (Flying Lead 250mm (10”)).
PRINCIPLE:
DIMENSIONS:
Standards:
Safety Classification and Reliability Data:
Minimum switched current:
Dielectric Withstand:
Insulation Resistance:
Recommended setting gap:
Switching Distance:
Tolerance to Misalignment:
Switching frequency:
Approach speed:
Body material:
Temperature Range:
Enclosure Protection:
Cable Type:
Mounting Bolts:
Mounting Position:
ISO14119 EN60947-5-3 EN60204-1
ISO13849-1 EN62061 UL508
10V.dc 1mA
250V.ac
100 Mohms
5mm
Sao 10mm Close
Sar 20mm Open
5mm in any direction from 5mm setting gap
1.0 Hz maximum
200mm/m to 1000mm/s
Polyester
-25/80C
IP67
PVC 6 or 8 core 6mm OD Conductors 0.25mm2
2 x M4 Tightening torque 1.0 Nm
Any
Characteristic Data according to IEC62061 (used as a sub system):
Safety Integrity Level SIL3
PFH (1/h) 4.77E-10 Corresponds to 4.8% of SIL3
PFD 4.18E-05 Corresponds to 4.2% of SIL3
Proof Test Interval T1 20a
SECTION 14
CONNECTION EXAMPLE:
RAMZSense LPZ - RFID CODED NON CONTACT WITH AUTO TEST
RFID Coded Non Contact with Auto Test Type: RAMZSense
Characteristic Data according to EN ISO13849-1:
Performance Level e If both channels are used in combination with a
SIL3/PLe control device
Category Cat4
MTTFd 1100a
Diagnostic Coverage DC 99% (high)
Number of operating days per year: dop = 365d
Number of operating hours per day: hop = 24h
B10d not mechanical parts implemented
When the product is used deviant from these assumptions (different load, operating
frequency, etc.) the values have to be adjusted accordingly.
Flying Lead
Colour
Circuit
(Actuator Present)
Brown
Blue
Black
Red
Orange
4
1
3
Yellow
White
Green
Supply +24Vdc
Supply 0Vdc
Safety Input 1
Safety Output 1
Safety Input 2
Safety Output 2
Auxiliary
Not used
For all IDEM switches the normally closed (NC) circuits are
closed when the guard is closed and the actuator is present.
UNIQUELY CODED
(every switch unique activation)
RAMZSense LPZ-U
RAMZSense LPZ-U
RAMZSense LPZ-U
RAMZSense LPZ-U
SALES
NUMBER
402001
402002
402003
402004
402200
MASTER CODED
(same code every switch)
RAMZSense LPZ-M
RAMZSense LPZ-M
RAMZSense LPZ-M
RAMZSense LPZ-M
Replacement Actuator Master Coded
140101
140102
Female QC Lead
Female QC Lead
CABLE LENGTH
2M
5M
10M
QC-M12
CABLE LENGTH
2M
5M
10M
QC-M12
M12 Female 5m. 8 way
M12 Female 10m. 8 way
www.idemsafety.com
Quick Connect QC
M12 8 Way Male Plug
Pin view from Switch
2
7
5
8
6
SALES
NUMBER
402101
402102
402103
402104
127