CFX12 04 Solver

Download Report

Transcript CFX12 04 Solver

Chapter 4
Solver Settings
Introduction to CFX
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-1
April 28, 2009
Inventory #002598
Solver Settings
Overview
Training Manual
• Initialization
• Solver Control
• Output Control
• Solver Manager
Note: This chapter considers solver settings for steady-state simulations.
Settings specific to transient simulation are discussed in a later chapter.
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-2
April 28, 2009
Inventory #002598
Solver Settings
Initialization
Training Manual
•
Iterative solution procedures require that all solution variables are
assigned initial values before calculating a solution
•
A good initial guess can reduce the solution time
•
In some cases a poor initial guess may cause the solver to fail
during the first few iterations
•
The initial values can be set in 3 ways:
1. Solver automatically calculates the initial values
2. Initial values are entered by the user
3. Initial values are obtained from a previous solution
•
Initial values can be set on a per-domain basis or globally for all
domains
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-3
April 28, 2009
Inventory #002598
Solver Settings
Initialization – Setting Initial Values
•
Insert Global Initialisation
from the toolbar or by rightclicking on Flow Analysis 1
•
Edit each Domain to set initial
values on a per-domain basis
–
–
Training Manual
When both are defined the
domain settings take
precedence
Solid domain must have
initial conditions set on a perdomain basis
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-4
April 28, 2009
Inventory #002598
Solver Settings
Initialization – Setting Initial Values
Training Manual
• The Automatic option means that the
CFX-Solver will calculate an initial value
for the solved variable unless a previous
results file is provided
– Will be based on boundary condition
values and domain settings
• The Automatic with Value option means
that the specified value will be used
unless a previous results file is provided
– Can use a constant value or an expression
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-5
April 28, 2009
Inventory #002598
Solver Settings
Initialization – Using a Previous Solution
Training Manual
• To use a previous solution as the
initial guess enable the Initial Values
Specification toggle when launching
the Solver
– You can provide multiple initial values
files
• When simulating a system you can
provide previous solutions for each
component of the system as the initial
guess
• Usually each file would correspond to a
separate region of space
• It is best if domains in the Solver Input
File do not overlap with multiple initial
values files
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-6
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Editing
Training Manual
• Edit the Solver Control object in the Outline tree
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-7
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Options
Training Manual
• The Solver Control panel contains
various controls that influence the
behavior of the solver
• These controls are important for the
accuracy of the solution, the stability of
the solver and the length of time it takes
to obtain a solution
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-8
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Advection Scheme
Training Manual
• The Advection Scheme refers to the way the
advection term in the transport equations is
modeled numerically
– i.e. the term that accounts for bulk fluid motion
– Often the dominant term
Unsteady
Advection
Diffusion
Generation
• Three schemes are available, High
Resolution, Upwind and Specified Blend
– Discussed in more detail next
• There is rarely any reason to change from the
default High Resolution scheme
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-9
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Advection Scheme Theory
Training Manual
• Solution data is stored at nodes, but variable values are required at
the control volume faces to calculate fluxes
• The upstream nodal values (fup) are interpolated to the integration
points (fip) on the control volume faces using:
f ip = f u p + b  f   r
f i p = gradient
fup + b 
f   r is the vector between the
– Where  f is the variable
and
upstream node and the integration point
– In other words, the ip value is equal to the upstream value plus a
correction due to the gradient
– b can have values between 0 and 1 …
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-10
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Advection Scheme Theory
Flow is misaligned
with mesh
f ip = f u p + b  f   r
Training Manual
Theory
1
• If b = 0 we get the Upwind advection
scheme, i.e. no correction
0
– This is robust but only first order accurate
– Sometimes useful for initial runs, but
usually not necessary
Upwind Scheme
• The Specified Blend scheme allows you to
specify b between 0 and 1 (i.e. between no
correction up to full correction)
– But this is not guaranteed to be bounded,
meaning that when the correction is
included it can overshoot or undershoot
what is physically possible
• The High Resolution scheme maximizes b
throughout the flow domain while keeping
the solution bounded
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-11
b=1.00
High Resolution
Scheme
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Turbulence Numerics
Training Manual
• Regardless of the Advection Scheme
selection, the Turbulence equations
default to the First Order (Upwind)
scheme
– Usually this is sufficient
• The High Resolution scheme can be
selected for additional accuracy
– Can give better accuracy in boundary
layers on unstructured meshes
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-12
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Convergence Control
Training Manual
• The Solver will finish when it reaches Max.
Iterations unless convergence is achieved
sooner
– If Max. Iterations is reached you may not have
a converged solution
– Can be useful to set Max. Iterations to a large
number
• When the Solver finishes you should always
check why it finished
• Fluid Timescale Control sets the timescale in
a steady-state simulation …
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-13
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Timescale Background
Training Manual
• ANSYS CFX employs the so called False Transient Algorithm
– A timescale is used to move the solution towards the final answer
• In a steady-state simulation the timescale provides relaxation of the
equation non-linearities
• A steady-state simulation is a “transient” evolution of the flow from the
initial guess to the steady-state conditions
– Converged solution is independent of the timescale used
Initial Guess
50 iterations
100 iterations
150 iterations
Final Solution
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-14
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Timescale Selection
Training Manual
• For obtaining successful
convergence, the selection of the
timescale plays an important role
– If the timescale is too large, the
convergence becomes bouncy or
may even lead to the failure of the
Solver
– If the timescale is too small, the
convergence will be very slow and
the solution may not be fully
accurate
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-15
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Timescale Selection
Training Manual
• For advection dominated flow, a fraction of the fluid residence time is
often a good estimate for the timescale
– A timescale of 1/3 of (Length Scale / Velocity Scale) is often optimal
– May need a smaller timescale for the first few iterations and for complex
physics, transonic flow,…..
• For rotating machines, 1/ ( in rad/s) is a good choice
• For buoyancy driven flows, the timescale should be based on a
function of gravity, thermal expansivity, temperature difference and
length scale (see documentation)
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-16
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Timescale Control
Training Manual
• Timescale Control can be Auto Timescale,
Physical Timescale or Local Timescale
Factor
• Physical Timescale
– Specify the timescale. Usually a constant but
can also be variable via an expression
– Can often set a better timescale than Auto
Timescale would produce – faster
convergence
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-17
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Timescale Control
Training Manual
• Auto Timescale
– The Solver calculates a timescale based on
boundary / initial conditions or current solution
and domain length scale
– Use a Conservative or Aggressive estimate for
the domain length scale, or a specified value
– Timescale is re-calculated and updated every
few iterations as the flow field changes
– Can set a Maximum Timescale to provide an
upper limit
– Tends to produce a conservative timescale
– Timescale factor (default = 1) is a multiplier
which can be changed to adjust the
automatically calculated timescale
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-18
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Timescale Control
Training Manual
• Local Timescale Factor
– Timescale varies throughout the domain
Local Mesh Length Scale
Local Timescale =
Local Velocity Scale
Smaller Timescale in high
velocity and/or fine mesh regions
– Can accelerate convergence when vastly different local velocity scales exist
• E.g. a jet entering a plenum
– Best used on fairly uniform meshes, since small element will have a small
timescale which can slow convergence
– Local Timescale Factor is a multiplier of the local timescale
– Never use as final solution; always finish off with a constant timescale
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-19
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Convergence Criteria
Training Manual
• Convergence Criteria settings determine
when the solution is considered converged
and hence when the Solver will stop
– Assuming Max. Iterations is not reached
• Residuals are a measure of how accurately
the set of equations have been solved
– Since we are iterating towards a solution, we never
get the exact solution to the equations
– Lower residuals mean a more accurate solution to
the set of equations (more on the next slide)
– Do not confuse accurately solving the equations
with overall solution accuracy – the equations may
or may not be a good representation of the true
system!
– Residuals are just one measure of accuracy and
should be combined with other measures:
• Monitor Points (ch. 8) and Imbalances (below)
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-20
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Residuals Theory
Training Manual
• The continuous governing equations are discretized into a set of linear
equations that can be solved. The set of linear equations can be written in
the form:
[A] [Φ] = [b]
where [A] is the coefficient matrix and [Φ] is the solution variable
• If the equation were solved exactly we would have:
[A] [Φ] - [b] = [0]
• The residual vector [R] is the error in the numerical solution:
[A] [Φ] - [b] = [R]
• Since each control volume has a residual we usually look at the RMS
average or the maximum normalized residual
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-21
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Residuals
Training Manual
• Residual Type
– MAX: Convergence based on maximum
residual anywhere
– RMS: Convergence based on average
residual from all control volumes
– Root Mean Square =

2
Ri
i
n
• Residual Target
– For reasonable convergence MAX residuals
should be 1.0E-3, RMS should be at least
1.0E-4
– The targets dependent on the accuracy
needed
• Lower values may be needed for greater
accuracy
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-22
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Conservation Target
Training Manual
• The Conservation Target sets a target for the
global imbalances
% Imbalance

Flux In  Flux Out
Maximum
Flux
• The imbalances measure the overall
conservation of a quantity (mass, momentum,
energy) in the entire flow domain
• Clearly in a converged solution Flux In should equal Flux Out
• It’s good practice to set a Conservation Target and/or monitor the
imbalances during the run
• When set, the Solver must meet both the Residual and Conservation Target
before stopping (assuming Max. Iterations is not reached)
• Set a target of 0.01 (1%) or less
– Flux In – Flux Out < 1%
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-23
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Elapsed Time and Interrupt Control
Training Manual
• Elapsed Time Control
– Can specify the maximum wall clock time
for a run
– Solver will stop after this amount of time
regardless of whether it has converged
• Interrupt Control
– Can specify other criteria for stopping
the Solver based on logical CEL
expressions
– When the expression returns true the
solver will stop
• Any value >= 0.5 is true
– Examples
• If temperature exceeds a specified value
if(areaAve(T)@wall>200[C],1,0)
• If mesh quality drops below a specified value in a moving mesh case
– More on logical expressions in the CEL lecture
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-24
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Solid Timescale Control
Training Manual
• This option is only available when a solid
domain is included in the simulation
• The Solid Timescale should be selected such
that it is MUCH larger than the fluid timescale
(100 times larger is typical)
– the energy equation is usually very stable in
the solid zone
– solid timescales are typically much larger than
fluid timescales
• The fluid timescale is estimated using Length Scale / Velocity Scale
• The solid timescale is automatically calculated as function of the length
scale, thermal conductivity, density and specific heat capacity
– Or you can choose the Physical Timescale option and provide a timescale
directly
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-25
April 28, 2009
Inventory #002598
Solver Settings
Solver Control – Equation Class Settings
Training Manual
• The Equation Class Settings tab is an
advanced option that can be used to
set Solver controls on an equation
specific basis
– Not usually needed
– Will override the controls set on Basic
Settings for the selected equation
• Advanced Options
– Advanced solver control options
– Rarely needed
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-26
April 28, 2009
Inventory #002598
Solver Settings
Output Controls – Results
Training Manual
• The Output Control settings control the output
produced by the Solver
– The Trn Results, Trn Stats and Export tab only apply to
transient simulations and are covered in the Transient
chapter
• The Results tab controls the final .res file
– Generally do not use the Selected Variables (or None!)
option since it probably won’t contain enough
information to restart the run later
– Output Equation Residuals is useful if you need to
check where convergence problems are occurring
– Extra Output Variables List
contains variables that are not
written to the standard results
file
• E.g. Vorticity
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-27
April 28, 2009
Inventory #002598
Solver Settings
Output Controls – Backup
Training Manual
• The Backup tab controls if and when
backup results files are automatically
written by the Solver
• Recommend for long Solver runs in case
of power failure, network interruptions, etc
• Option:
– Standard: Like a full results file
– Essential: Allows a clean solver restart
– Smallest: Can restart the solver, but
there’ll be a jump in the residuals
– Selected Variables: Not recommended
• Can also manually request a backup file
from the Solver Manager at any time
Frequency of output can be adjusted
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-28
April 28, 2009
Inventory #002598
Solver Settings
Output Controls – Monitor
Training Manual
• The Monitor tab allows you to create Monitor
Points
– These are used to track values of interest as
the Solver runs
• The Cartesian Coordinates Option is used to
track the value of a variable at a specific X, Y,
Z location
• The Expression Option is used to monitor the
values of a CEL expression
– E.g. Calculate the area average of Cp at the
inlet boundary: areaAve(Cp)@inlet
– E.g. Mass flow of particular fluid through an
outlet: oil.massFlow()@outlet
• In steady-state simulations you should create
monitor points for quantities of interest
– One measure of convergence is when these
values are no longer changing
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-29
April 28, 2009
Inventory #002598
Solver Settings
Solver Manager
Training Manual
• The CFX-Solver Manager is a graphical user interface used to:
–
–
–
–
Define a run
Control the CFX-Solver interactively
View information about the emerging solution
Export data
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-30
April 28, 2009
Inventory #002598
Solver Settings
Solver Manager – Defining a Run
Training Manual
• Define a new Solver run
• Solver Input File should be the .def file
– Can also pick .res, .bak or _full.trn files to restart a
previous incomplete run
• To make a physics change and restart a solution,
create a new .def file and provide it as the Solver
Input File then select the .res, .bak or _full.trn file
in the Initial Values Specification section
– If both files have the same physics, this is the same
as picking the .res/.bak/_full.trn file as the input file
• Use Mesh From selects which mesh to use. If the
meshes are identical can use either option,
otherwise:
– If you use the Solver Input File mesh, the Initial
Values solution is interpolated onto the input file
– If you use the Initial Values mesh only the physics
from the Solver Input File is used
• Continue History From carriers over convergence
history and iteration counters
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-31
April 28, 2009
Inventory #002598
Solver Settings
Solver Manager – Defining a Parallel Run
Training Manual
• By default the Solver will run in serial
– A single solver process runs on the local
machine
• Set the Run Mode to one of the parallel options
to make use of multiple cores/processors
– Requires parallel licenses
– Allows you to divide a large CFD problem into
smaller partitions
• Faster solution times
• Solve larger problems by making use of memory
(RAM) on multiple machines
• The Local Parallel options should be used
when running on a single machine
• The Distributed Parallel options should be
used when running across multiple machines
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-32
April 28, 2009
Inventory #002598
Solver Settings
Solver Manager – Defining a Parallel Run
Training Manual
• Serial
• Local Parallel
• Distributed Parallel
• Different communication methods are available (MPICH2, HP MPI, PVM)
– See documentation “When To Use MPI or PVM” for more details, but HP MPI is
recommended in most cases
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-33
April 28, 2009
Inventory #002598
Solver Settings
Solver Manager – Define Run Advanced Controls
Training Manual
• The Show Advanced Control toggle enables the
Partitioner, Solver and Interpolator tabs
• On the Partitioner tab you can pick different
partitioning algorithms
– Partitioning is always a serial process
– Can be a problem for v.large cases since you
cannot distribute the memory load across multiple
machines
– The default MeTiS algorithm uses more memory
than others, so if you run out of memory use a
different method (see documentation for details)
• Multidomain Option:
– Independent Partitioning: Each domain is
partitioned into n partitions
– Coupled Partitioning: All domains are combined
and then partitioned into n partitions
• There’s a specific option for Transient Rotor Stator
cases
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-34
April 28, 2009
Inventory #002598
Solver Settings
Solver Manager – Define Run Advanced Controls
Training Manual
• On the Solver tab you can select the Double
Precision option
– The solver will use more significant figures in its
calculations
– Doubles solver memory requirements
– Use when round-off error could be a problem – if
‘small’ variations in a variable are important,
where ‘small’ is relative to the global range of
that variable, e.g:
• Many Mesh Motion cases, since the motion is often
small relative to the size of the domain
• Most CHT cases, since thermal conductivity is
vastly different in the fluid and solid
• If you have a wide pressure range, but small
pressure changes are important
– Small values by themselves do not need DP
• The Solver estimates its memory requirements upfront
• Memory Alloc Factor is a multiplier for this estimate
– Use when the solver stops with an “Insufficient Memory Allocated” error
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-35
April 28, 2009
Inventory #002598
Solver Settings
Solver Manager – Interactive Solver Control
Training Manual
• During a solution Edit Run in Progress lets you make changes on the fly
– Models generally cannot be changed, but timescales, BC’s, etc can
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-36
April 28, 2009
Inventory #002598
Solver Settings
Solver Manager – Additional Solution Monitors
• By default monitor plots
are created showing the
RMS residuals for each
equation solved, plus one
plot for any monitor points
• Right-click to switch
between RMS and MAX
• Additional monitors can be
selected showing:
Training Manual
New Monitor
– Imbalances
– Boundary fluxes (FLOW)
– Boundary forces
• Tangential (viscous)
• Normal (pressure)
Right-click
– Source terms …
Monitor Plot
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
4-37
.out file
April 28, 2009
Inventory #002598
Solver Settings
Solver Manager – Additional Icons
Training Manual
• By dragging the cursor over any icon, the feature
description will appear
Start a new
Simulation
Monitor
Finished Run
Stop Current
Run
Monitor Run
in Progress
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
Switch
Residual Plot
between
RMS and
MAX
Save Current
Run
4-38
April 28, 2009