IAEA Training Material on Radiation Protection in Diagnostic and Interventional Radiology RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 15.8: Optimization of protection in radiography Practical.
Download ReportTranscript IAEA Training Material on Radiation Protection in Diagnostic and Interventional Radiology RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 15.8: Optimization of protection in radiography Practical.
IAEA Training Material on Radiation Protection in Diagnostic and Interventional Radiology RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 15.8: Optimization of protection in radiography Practical exercise - Grid IAEA International Atomic Energy Agency Contents/Overview • Subject matter : quality control of general radiography system • Step by step procedure to be followed to assess the grid performance • Interpretation of results IAEA 15.8: Optimization of protection in radiography 2 IAEA Training Material on Radiation Protection in Diagnostic and Interventional Radiology Part 15.8: Optimization of protection in radiography Grid (system factor, homogeneity) IAEA International Atomic Energy Agency What Minimum Equipment is Needed? • Dosimeter • Acrylic 20 cm thick • Densitometer IAEA 15.8: Optimization of protection in radiography 4 Antiscatter grid - grid system factor (I) • The grid system factor can be measured with a dosimeter • Produce two images, one with and one without the grid system • Use manual exposure control to obtain images with an optical density of about 1.00. IAEA 15.8: Optimization of protection in radiography 5 Antiscatter grid - grid system factor (II) • The first image is made with the cassette in the bucky tray (with grid system) and acrylic on top of the table, and the second with the cassette on top of the table (without grid system) and acrylic on top of the cassette IAEA 15.8: Optimization of protection in radiography 6 Antiscatter grid - grid system factor (III) • The grid system factor is calculated by dividing the exposures, corrected for the inverse square law and optical density differences Limiting value : Grid system factor 3. Frequency : Initially and when dose or exposure time increases suddenly IAEA 15.8: Optimization of protection in radiography 7 Grid imaging • To assess the homogeneity of the grid in case of suspected damage or looking for the origin of artefacts, the grid may be imaged by automatic exposure of the bucky at the lowest position of the AEC-selector, without any added acrylic • In general, this gives a good image of the gridlines IAEA 15.8: Optimization of protection in radiography 8 Where to Get More Information Quality Control in Diagnostic Imaging, Gray JE, Winkler NT, Stears J, Frank ED. Available at no cost. http://www.diquad.com/QC%20Book.html IAEA 15.3: Optimization of protection in radiography 9