SLAC Aerial View SLAC Timing System Specifications Blue Book: (~1968) PEP – II: (~1998) - Resolution: 50 nSec - Resolution: 2.1 nSec - Jitter: 15 nSec - Jitter:

Download Report

Transcript SLAC Aerial View SLAC Timing System Specifications Blue Book: (~1968) PEP – II: (~1998) - Resolution: 50 nSec - Resolution: 2.1 nSec - Jitter: 15 nSec - Jitter:

SLAC Aerial View
SLAC Timing System Specifications
Blue Book:
(~1968)
PEP – II:
(~1998)
- Resolution: 50 nSec
- Resolution: 2.1 nSec
- Jitter: 15 nSec
- Jitter: 20 pSec
- Main Trigger Line
- NIM Level
Waveform:
Waveform:
+ / - 400 Volts
0 to –0.7 V into 50 Ohms
Historical MCC Timing Units
Machine Cycle
1 / 360 Second = 2.78 mSec
Timing System Enclosure
Waveforms: 476 MHz with FIDUCIALS
LINAC
PEP - 2
Waveforms: 119 MHz and NIM Pulse
FIDO Output
PDU Output
SLAC Landscape
Trigger Generation, simplified
Sector 0 Trigger Generation, oversimplified
Trigger Generation, simplified
Area Three, Rack One
Area One, Rack One CAMAC
Trigger Distribution: Sector 0 and 1
476 Mhz
FROM
MDL
COUPLER
AMPLIFIER
AND SPLITTER
476 Mhz TO
DAMPING RING
SECTOR 0
FEEDBACK
FIDO
119
DISTRIBUTION
119 Mhz
to CID
VAULT
FIDO
119
DISTRIBUTION
119 Mhz
to SECTORS
0 and 1
Klystron Gallery
Trigger Distribution: Damping Rings
476 Mhz
from
S0 Alcove
FIDO
476 Mhz
119
DISTRIBUTION
119 Mhz
to
South Ring
FIDO
119
DISTRIBUTION
119 Mhz
to
North Ring
LINAC Rack, Front
LINAC Rack, Rear
MDL Coupled Output
LINAC Timing Sector TEN
MDL Coupler
476 Mhz
476 Mhz
Splitter
SECTOR 10
SUBBOOSTER
476 Mhz
FIDO
119 Mhz
PDU
PDU
PDU
Li09 Cr 4
Li10 Cr 2
Li10 Cr 3
LINAC Timing Diagnostic
Fiber Optic Xmtr
Fiber Optic Link
Bldg 407
TOP of S-30 SUB-Booster
FIBER OPTIC
TRANSMITTER
FIBER OPTIC
RECEIVER
476 MHz
Bldg 407
Bldg 062
NLCTA
476 MHz
AMPLIFIER
and
SPLITTER
TERM
NLCTA Trigger Distribution
NLCTA Triggers
Bldg 407
Bldg 407
FIBER OPTIC
RECEIVER
AMPLIFIER
and
SPLITTER
476 Mhz
476 Mhz
Bldg 062
476 Mhz
Distribution
476 Mhz
TERM
RF REFERENCE
SYSTEM
FIDO
PDU
119 Mhz
Distribution
PDU
PDU
NLCTA Beam Line
PEP – 2 Timing Generation
MAIN DRIVE LINE
PEP - 2
CONTROL
LINE
DIST
CHASSIS
PEP 2 FIDUCIAL GENERATOR
125-843
PHASE LOCK
AND
INJECTION
FIDUCIAL
DETECTOR
PEP - 2
MASTER
OSCILLATOR
476 Mhz
POWER AND
VOLTAGE
MONITORS
PEP – 2 Timing Equipment
PEP – 2 Timing Distribution
TPLD
REGION
12
TPLD
REGION
2
TPLD
REGION
10
PEP - 2
MASTER
OSCILLATOR
TPLD
REGION
8
PEP - 2
FIDUCIAL
GENERATOR
TPLD
REGION
6
TPLD
REGION
4
PEP – 2 Klystrons
SLC Timing Distribution
S30 MAIN DRIVE LINE
SECTOR 30
MDL
DISTRIBUTION
476 Mhz
476 Mhz
FIDO
119 Mhz
119 DIST
119 Mhz
119 DIST
119 DIST
119 DIST
119 DIST
119 DIST
119 DIST
PDU
Bldg 725
Spltr
Bldg 669
Bldg 136
Bldg 750
Bldg 757
119 DIST
Bldg 751
119 Mhz
PDU
Bldg 136 Trigger Distribution
119 MHz Propagation in SLC
Sector 30 “Source”
Final Focus
Some Timing Modules
•
•
•
•
•
FIDO
PDU (SLC)
PDU (PEP – 2)
Simple Timing Buffer
VDU
• 476 MHz Distribution
• 119 MHz Distribution
• PEP – 2 Timing Phase
Lock and Distribution
FIDO Unit
FIDO B. D.
2.5 mSec
LOCKOUT
476 Mhz
Splitter
BANDPASS
FILTER
RESET
INHIBIT
FIDUCIAL
DETECTOR
8 nSec
ONE-SHOT
DIVIDE
By 4
DRIVER
PDU
OUTPUTS
DIVIDE
By 4
DRIVER
PSU
OUTPUTS
PDU – SLC Style
119 Mhz
Counter
Detector
Glue
Logic
RE-USE
To CAMAC
Upper Timing
Backplane
Register
Sixteen channels per PDU;
One channel shown
Differential
ECL Output
From
CAMAC
LINAC Timed Crate
PDU, Backplane, and STB
119 MHz
STB
PDU
CAMAC
Upper Timing
BACKPLANE
Front
Panel
16 Channels
LEMO
Connectors
NIM
Level
Outputs
16
Channels
Delay Output Generator
Voltage Monitor Interval Timer
Designer’s original module names. Refer to Proverbs 26:11, KJV
PEP – 2 Timed Crate
Vernier Delay Unit
476 Distribution Unit
476 MHz Distribution B.D.
476 Mhz
Variable
Attenuator
AMP
Splitter
AMP
Splitter
476 Mhz
To FIDOs
Splitter
476 Mhz
To FIDOs
FIDOs and 119 Distribution
119 MHz Distribution B.D.
Variable
Attenuator
119 Mhz
AMP
Splitter
119 Mhz
To PDUs
Splitter
Variable
Attenuator
AMP
119 Mhz
To Next
Distribution Unit
TPLD Chassis Front Panel
Timing Phase Lock Distribution B.D.
Graphic by E.L.Cisneros
TPLD SCP Diagnostics 1
TPLD SCP Diagnostics 2
Some Triggered Devices
• Kickers
• Single Beam Dumper
Logic
• Beam Position
Monitors
• Toroid Charge
Monitors
• Trigger Gate and
Synchronizer
Damping Ring Kicker Triggers
Single Beam Dumper Logic Module
Toroid Charge Monitor B.D.
Ch 11 Trig
Ch 12 Enable
TOROID
on Beam Line
Rocks
Some Common Timing Problems
• Jitter
• FIDO – related
Failures
• Connections
• Bucket Jump
• Undocumented
modifications
280