An Echidna-style positioner for DESpec
Will Saunders
AAO
27th June 2011
General considerations
• DESpec requires ~4000 fibres over 450mm focal plane:
Nfibres = 1832 (10/p)2  7mm pitch (or less!)
• WFC delivers F/2.88 – F/2.96 - perfect for standard fibres
• Plate scale 17.6"/mm + 1.8" apertures  ~100m core fibres.
• Fibre systems want telecentric input  curved focal plane
• Wide Field Corrector > 1 metre diameter - lots of room
• Cost, simplicity, modularity, paramount.
• FMOS instrument for Subaru needed 400 fibres in 150mm diameter
focal plane - so needed a completely new and very compact design.
• Echidna uses 'spines’ – fibres in carbon-fibre spines, with a piezodriven magnetic stick-slip mechanism to position fibres.
• 7.2mm pitch between fibres
• Few m positioning accuracy
• Very short repositioning times*
Echidna features
• 400 fibres, 7.2mm pitch.
• Few seconds per repositioning iteration,
spines reposition in parallel*, several
iterations per fibre.
• <10 m final positioning error.
• Spines introduce inevitable focal errors,
(up to 86 m for Echidna).
• Spines also introduce telecentricity
errors, up to 2.75 for Echidna.
• Patrol radius allows 3-fold covering of
focal plane. When Ntargets  Nfibres,
fibering efficiency is ~85%, versus 63%
for LAMOST-style positioner.
NOT TO SCALE
Echidna in operation
WFMOS-Echidna proposal
2005 proposal for 4500 fibre positioner for Gemini, primarily to
study dark energy. Very close to DESpec requirements!
WFMOS concept design
•
•
•
•
•
Proposal evolved into concept design for Subaru.
500mm FOV, 3000 spines, 8.7mm pitch, adjustable length.
Curved focal plane (5m ROC).
Fully prototyped at AAO
Lost out to COBRA!
WFMOS-A concept design
•
•
•
•
•
2008 proposal for WFMOS for AAT
1600 spines over 450mm FOV, 11.2mm pitch
Simplified design, 7 spine parts  3, no glue
Pitch limited to ~8.5mm by 8mm ball bearing
Smaller pitch requires ¼" ball-bearing, would give
<7mm pitch. Should be fine but must prototype!
Metrology and positioning times
• Must back-illuminate spines. Either back-illuminate science
fibres, or add extra metrology fibres to spines.
• Image from single 4Kx4K camera mounted in Cass chimney,
1/20 pixel centroiding (easy) gives 6m precision.
• Individual moves < 10s, but need few iterations to reach
10m precision ("Par 3"). 130s conservative overall budget.
WFMOS-A concept design
Rest of Package:
•
•
•
•
AAO provides whole data
taking package, based on our
2dF, 6dF, AAOmega, Echidna,
Ozpos, HERMES experience.
Now routine to modify package
for different instruments and
telescopes. Package includes:
Observing planning software
Configuring software
Interface between instrument
and telescope (instrument
usually drives telescope)
Data reduction pipeline
Configuring software
Configuring software
includes guide stars,
target priorities,
checking for validity
over range of Hour
Angles, etc.
Now based on
simulated annealing,
can't do better!
Configuring software
Configuring software
includes guide stars,
target priorities,
checking for validity
over range of Hour
Angles, etc.
Now based on
simulated annealing,
can't do better!
Patrol radius vs yield
Yield (fraction of fibres
used) and completeness
(fraction of targets
observed) both increase
with patrol radius.
Product peaks at 70%,
when Ntargets ~ Nfibres
7mm pitch, 4-7mm patrol
radius (1.5 field)
Data reduction
• AAO has state-of-the-art fibre spectroscopy
data reduction pipeline. Very flexible and robust.
• PCA (Principal Component Analysis) sky
subtraction now routine  Poisson-limited sky
subtraction with dedicated sky-fibres.
Data reduction
• AAO has state-of-the-art fibre spectroscopy
data reduction pipeline. Very flexible and robust.
• PCA (Principal Component Analysis) sky
subtraction now routine  Poisson-limited sky
subtraction with dedicated sky-fibres.
Proposed DESpec design
• R&D program to determine minimum viable spine pitch, aim for
6.75mm (4000 fibres total).
• Use Polymicro FBP fibre – cheap, available, excellent FRD and
transparency (few % over 30m for 600-1000nm).
• Use 104/125m core/cladding: fits standard telco connectors,
cladding thickness ok to 1m (10), gives 1.83" aperture on sky.
• Make modules curved (only 3.2mm sag) and tapered, to fit
together to form section of sphere. All modules identical, all
spines same length, all telecentric.
• Maximum defocus 57m, (1/3"), ~2% light loss.
• Maximum telecentricity error 2, vs 10 beam radius, ~2 % light
loss.
Spectrograph thoughts: Plan A
• 6000Å -10000Å coverage @ 3Å resolution (R=3300@10000Å)
 1333 spectral resolution elements.
• Can cover with single 4K detector if PSF FWHM  3 pixels.
• 100m fibres, 3 pixel FWHM  camera speed  F/1.4
 Schmidt optics
• VPH gratings have high efficiency only over small field angles, so
want long camera  large beam-size (250mm minimum).
• Large beam also means small obstruction losses for Schmidt
cameras, so attractive option. Obstruction losses partially
shadowed by prime focus obstruction anyhow.
• Schmidt correctors cheaper now with MRF technology.
• Smart to design for 2 x 2K x 4K detectors in each camera, would
need ~6 spectrographs only.
Spectrograph thoughts: Plan A
Schmidt/Schmidt design, 250mm beam, F/1.3
camera. F/2.75 collimator  2 correctors needed.
Fixed format, so can put prisms between VPH and
correctors, to reduce air-glass surfaces. Almost all
cheap glass.
Optics are good (rms radius < 10m).
Cost of optics $80K ROM
Dewar is whole camera or CCD + field flattener?
Spectrograph thoughts: Plan B
• 2-armed design removes many constraints.
• 5000Å -10000Å coverage @ 2.5Å resolution (R=4000@10000Å)
 2000 spectral resolution elements.
• Can cover with 2 x 4K detector if PSF FWHM  4 pixels.
• 100m fibres, 4 pixel FWHM  camera speed  F/1.85
 transmissive design is fine (and more efficient).
• VPH angles  still want long camera and large beam-size.
• Smart to design for 2 x 2K x 4K detectors in each camera, would
need ~8 spectrographs.
Spectrograph thoughts: Plan B
• JHU WFMOS (evolution of SDSS to 4K x 4K detectors) is very
efficient, compact, and affordable @ $1M each.
• 159mm beam, f/1.5 cameras. Would need to add collimator
correctors for DESpec
• Smart to design for 2 x 2K x 4K detectors in each camera, would
need ~8 spectrographs.