Duct Sealing Savings: SEEM Modeling compared to ETO Evaluation Results Regional Technical Forum October 13, 2009
Download ReportTranscript Duct Sealing Savings: SEEM Modeling compared to ETO Evaluation Results Regional Technical Forum October 13, 2009
Duct Sealing Savings: SEEM Modeling compared to ETO Evaluation Results Regional Technical Forum October 13, 2009 • SEEM SEEM Runs - Portland Weather - Electric Forced Air Furnace Baseline Duct System Duct R-Value Supply Return Duct Prototype UA (Supply / Leak Leak Sys Return) Fraction Fraction Eff SF 1344 345 4/4 0.15 0.10 76% SF 2200 512 4/4 0.15 0.10 74% SF 2688 576 4/4 0.06 0.10 91% MH 924 247 20/infinite 0.15 0.00 79% MH 1568 359 20/infinite 0.15 0.00 82% MH 2352 504 20/infinite 0.15 0.00 82% Prototype Weightings Prototype (SF/MH) Site Built Manuf Home Small (1344/924) 75% 80% Medium (2200/1568) 16% 16% Large (2688/2352) 9% 4% Average Size (sqft) 1,602 1,084 PTCS Duct System Duct Seal Supply Return Duct Savings Leak Leak Sys (kWh/yr) Fraction Fraction Eff 0.05 0.03 88% 1,298 0.05 0.03 86% 2,601 0.01 0.01 100% 1,215 0.05 0.00 93% 865 0.05 0.00 93% 1,133 0.05 0.00 93% 1,672 Weighted SEEM Savings (kWh/yr) Portland 1,499 • ETO ETO Savings - Converted to Electric FAF Savings Savings Range Gas FAF Eff Savings (kWh) Low (46 therms) 75% 1,011 High (55 therms) 90% 1,451 Discussion • With these assumptions, SEEM over-predicted savings – but not by much • However, the specific characteristics of the houses in the ETO study are different than what was modeled in SEEM – – – – Pre/Post duct system efficiency levels Gas furnace efficiency Average house size Average house insulation levels • SEEM model used cost-effective limit, ETO homes likely not quite there on average – making this adjustment would cause higher SEEM savings – Climate – Takeback • What additional steps, if any, should be taken to calibrate SEEM runs? (The RTF uses it for a number of residential measures)