SENA One-Stop Solution in Device Networking HelloDevice Super series SS100/110/400/800 www.sena.com Dec, 2004 Contents Overview Configuration Ways Text-based Interface Web-based Interface Features Operation Modes TCP/UDP Multiple Remote Hosts
Download ReportTranscript SENA One-Stop Solution in Device Networking HelloDevice Super series SS100/110/400/800 www.sena.com Dec, 2004 Contents Overview Configuration Ways Text-based Interface Web-based Interface Features Operation Modes TCP/UDP Multiple Remote Hosts
SENA One-Stop Solution in Device Networking HelloDevice Super series SS100/110/400/800 www.sena.com Dec, 2004 Contents Overview Configuration Ways Text-based Interface Web-based Interface Features Operation Modes TCP/UDP Multiple Remote Hosts Security PC Card Support Data Logging Event Handling SNMP Dynamic Domain Name Customization Support Case Studies Door Access Application (Customized) Medical Application (Customized) Bridge Monitoring System www.sena.com 2 Overview (1) • Linux-based Open platform (kernel 2.4.2) • Supports 1/4/8 serial port (RS232/422/485) • 1 PCMCIA slot – ATA flash memory, LAN/WLAN, PSTN/CDMA Modem • Flexible host mode mode – TCP/UDP single/multi-session support – Primary/Secondary host support • Powerful Security – Industry-standard encryption support • SSL v3, and TLS v1 – Encryption algorithm support • 3DES, and RC4 • Flexible customization – Linux CLI with development environment – Source file add/modify/compile/link in 1MB user space – Web customization www.sena.com 3 4 Overview (2) Connections Remote Host Device Host (SS) • LAN • RS-232 • Wireless (802.11b) • RS-422 • PSTN • RS-485 • Mobile (CDMA) www.sena.com Any device with serial interface Configuration Ways 1. Text-based Interface 2. Web-based Interface www.sena.com Text-based Interface 1. 2. 3. System Console Telnet (port 23) or SSH (port 22) Privileges • Admin user can access and edit configuration parameters. • Root user can have full control on SS via CLI, in addition to access and configuration rights. www.sena.com 6 Web-based Interface Web-based interface using web browsers such as IE, Netscape and Opera www.sena.com 7 Features 1. 2. 3. 4. 5. 6. 7. 8. www.sena.com Operation Modes TCP/UDP Multiple Remote Hosts Security PC Card Support Data Logging and Event Handling SNMP Dynamic Domain Name Customization Support 9 Operation modes Various operation modes Remote host •TCP/UDP device TCP/UDP socket •modem emulation Remote host DTE TCP socket •Dial-in/out mode Remote host TCP socket modem modem www.sena.com DTE TCP/UDP Multicasting 1. 2. 3. 4. 5. www.sena.com Overview Configuration Connection Application Diagram Application Areas Overview • SS supports an enhancement transmission method "TCP/UDP multicasting", which transmits serial device data to multiple hosts simultaneously. • Max. 32 hosts (incoming+outgoing) per one port allowed. • Max. 16 outgoing connections (registered remote hosts) per one port allowed • Each registered TCP host can have a backup host • UDP host mode does not support backup host since there is no way to check status of primary remote host. • Multicasting feature is very useful in application areas where user needs to transmit a message to several display signboard devices simultaneously. www.sena.com 11 Configuration • Access the SS web interface – Choose Serial port --> Configuration --> Port # --> Remote host configuration www.sena.com 12 Connection www.sena.com 13 Application Diagram www.sena.com 14 Application Areas Applications which require Multiple data transmission include: • LED Signboard, • Electronic Metering, • Any customer requiring Multiple data transmission. www.sena.com 15 Security 1. 2. 3. 4. 5. www.sena.com SSL Encryption: Overview SSL Encryption: Configuration SSL Encryption: Connection Other Security Features Application Areas SSL Encryption: Overview • SSL creates a secure connection between a client and a server, over which any amount of data can be sent securely. • By setting the cryptography method as one of SSLv2, SSLv3, SSLv3 rollback to v2 or TLSv1, the Super Series can communicate with other device supporting SSL/TLS cryptography method in encrypted sessions. • SSL configuration settings are available only when the host mode is set to TCP or Modem Emulation mode. • SSL works by using a private key to encrypt data that's transferred over the SSL connection. www.sena.com 17 SSL Encryption: Configuration • Access the SS web interface – Choose Serial port --> Configuration --> Port # --> Host mode configuration – Choose Serial port --> Configuration --> Port # --> Cryptography configuration www.sena.com 18 SSL Encryption: Connection • Run SSL or TLS client application – openssl s_client –connect 192.168.0.2:6001 –ssl3 www.sena.com 19 Other Security Features Serial data encryption 3DES, RC4 Static Key encryption Secured Web interface HTTPS IP filtering serial port based IP filtering box based IP filtering Secured file uploading SCP www.sena.com 20 Application Areas Applications which require more secure communications include: • • • • • Financial, Retail/POS, Government, Medical, and Any customer requiring enhanced security to protect sensitive information. www.sena.com 21 PC Card Support 1. 2. 3. 4. 5. www.sena.com Overview CF Memory card configuration Modem card configuration LAN card configuration WLAN card configuration Overview • PC card types that can be added to the SS include a serial modem, compact-flash card, wireless LAN card, and a network LAN card. www.sena.com 23 CF Memory card configuration • Access the SS web interface – Choose PC Card --> Configuration www.sena.com 24 Modem card configuration • Access the SS web interface – Choose PC Card --> Configuration www.sena.com 25 LAN card configuration • Access the SS web interface – Choose PC Card --> Configuration www.sena.com 26 WLAN card configuration • Access the SS web interface – Choose PC Card --> Configuration www.sena.com 27 Data Logging and Event Handling 1. 2. 3. 4. www.sena.com Overview Data Logging Configuration Data Event Handling Configuration Data Event Handling Test Overview 29 • The SS can capture all system and port data, and save it into a log file. This buffer can be viewed from the web, saved to memory, or saved to a Flash Card, syslog server or NFS server. • System logs track events such as logins, authentication failures, system configuration changes, and more. • Port logs document the data flow through the SS serial ports. • In addition, the SS can be configured for system alerts and notifications. It can send email messages when an alarm message is detected in the serial port data. • The SS uses SMTP for sending email notifications and SNMP for trap alerts. www.sena.com Data Logging Configuration • Access the SS web interface – Choose Serial port --> Configuration --> Port # --> Port logging www.sena.com 30 Data Event Handling Configuration • Access the SS web interface – Choose Serial port --> Configuration --> Port # --> Port logging www.sena.com 31 Data Event Handling Test • Event Handling via SNMP browser and SMTP email www.sena.com 32 SNMP 1. Overview 2. Configuration 3. Connection www.sena.com Overview • SS supports SNMP that provides status and performance of connected serial devices through their Ethernet connections. • Applications such as NMS or an SNMP browser can exchange information with the SS. • The SS supports SNMP authentication, Login, and Link up traps. • The SS supports both versions 1 and 2 of the SNMP protocol and delivers the System and Port alerts as traps. www.sena.com 34 Configuration • Access the SS web interface – Choose Network --> SNMP configuration www.sena.com 35 Connection • Authentication, Login, and Link up traps in Kiwi SNMP browser www.sena.com 36 Dynamic Domain Name 1. Overview 2. Configuration and Connection www.sena.com Overview • Dynamic DNS Protocol enables users to access the SS via a domain name for floating IP environments such as DSL line and DHCP. • To use this service, users must set-up an account in Dynamic DNS Network Services and add domain name, user name and password on the SS DDNS configuration page. • Whenever user reboots the SS in floating IP environments, it sends updated IP address to Dynamic DNS Network Services. www.sena.com 38 Configuration and Connection • Access the SS web interface – Choose Network --> Dynamic DNS configuration • Access the SS web interface and use domain name • For e.g., ismdemo.dyndns.biz www.sena.com 39 Customization Support 1. 2. 3. 4. Overview User Web Customization - HTML pages User Web Customization – CGI & Java pages Serial Filter Application www.sena.com Overview • Web customization options – Plain HTML files – CGI written in C • User application implementation – Filter applications in C – Other applications in C or shell scripts • To quickly develop custom applications that run on the HelloDevice Super Series, SDK (Software Development Kit) is needed. • SS SDK is a 256MB CF card composed of executable binaries (including gcc), header files, and library files. – Executable binaries run on SS (MPC855T Linux) – Header files and Library files are compatible with SS platform • With SS SDK, users can compile their own C/C++ source code to run on SS without installing cross-compile utilities on their PC. www.sena.com 41 User Web Customization - HTML pages (1/3) Preparation • If you are using Windows, using SCP (secure copy protocol) client tools for Windows will be handy for file transfer from/to SS • Winscp (GUI) – Download @ http://winscp.sourceforge.net/eng/ – Install as other applications • Pscp (command line interface) – Download pscp.exe @ http://www.chiark.greenend.org.uk/~sgtatham/putt y/download.html – Copy pscp.exe into C:\Windows directory www.sena.com 42 User Web Customization - HTML pages (2/3) Running User HTML file • Prepare index.html file and other related files (e.g. index.html and webtest.swf) • Just copy the files to SS, /usr2/usrweb directory using SCP tools (e.g. winscp) and it will work! www.sena.com 43 User Web Customization - HTML pages (3/3) Browsing SS User Web Pages www.sena.com 44 User Web Customization – CGI & Java pages (1/3) Preparation: Recognizing SDK Card • After recognition, SDK is mounted on /mnt/flash/ directory [email protected]:~# editconf -----------------------------------------------------------------------------Welcome to SS-110 configuration page … IP mode: DHCP IP address: 192.168.0.15 -----------------------------------------------------------------------------Select menu: 1. Network configuration … <Enter> Refresh ---> 3 -----------------------------------------------------------------------------PC Card configuration -----------------------------------------------------------------------------Currently configured PC card: (none) Select menu: 1. Change card configuration 2. Stop the card service to disable or remove card 3. Probe a new card <ESC> Back, <Enter> Refresh ---> 3 Do you want to probe a new pc card? (y/n): y A new PC card is discovered. www.sena.com -----------------------------------------------------------------------------PC Card configuration -----------------------------------------------------------------------------Currently configured PC card: ATA/IDE fixed disk card Model: SanDisk SDP 5/3 0.6 Size: 257 MB File system: ext2 … ---> -----------------------------------------------------------------------------Welcome to SS-110 configuration page … -----------------------------------------------------------------------------Select menu: 1. Network configuration … 6. Exit without saving 7. Exit and apply changes 8. Exit and reboot <Enter> Refresh ---> 7 Are you sure to save changes? (y/n): y Saving.. Configuration is saved successfully Are you sure to apply changes? (y/n): y Applying........ Configuration is applied successfully 45 User Web Customization – CGI & Java pages (2/3) Compiling and Copying files • Make working directory such as /mnt/flash/work • Copy cgi source file (e.g. ex.c) into the working directory • Compile *.c file with the option of “–L/mnt/flash/lib” (Library path) • Copy *.cgi binary file to /usr2/cgi-bin/ directory • Copy index.html that has CGI link in it to /usr2/usrweb/ directory www.sena.com 46 User Web Customization – CGI & Java pages (3/3) Sample CGI Source file and Output [email protected]:/mnt/flash/work# cat ex.c #include <stdio.h> #include <stdlib.h> #include <string.h> main(int argc, int *argv[]) { printf("Content-type: text/html\n\n"); printf("<html>"); printf("<body bgcolor=\"#0000C0\">"); printf("<b><font color=\"#FF0000\">This is a sample CGI page</font></b>\ n"); printf("</body>"); printf("</html>\n"); fflush(stdout); } [email protected]:/mnt/flash/work# gcc -o ex.cgi ex.c -L/mnt/flash/lib [email protected]:/mnt/flash/work# cp ex.cgi /usr2/cgi-bin/ [email protected]:/mnt/flash/work# www.sena.com 47 48 Serial Filter Application (1/4) SS Serial Filter Structure • Users just need to write filter application only to customize serial port application rather than writing whole source code • Typical situation for serial application customization: – Add/remove protocol header – Periodically check serial device www.sena.com 49 Serial Filter Application (2/4) Sample file • Location = /mnt/flash/sample/filter • periodic_filter.c – Periodic query of the serial device application might start from here • empty_filter.c – Do nothing. Adding/removing header application might start from here www.sena.com 50 Serial Filter Application (3/4) How to • Log into the SS (Telnet or SSH) • Copy sample file from SDK to working directory (e.g. /mnt/flash/work) • Compile source file (Be careful with compile options) gcc -o myfilter myfilter.c -L/mnt/flash/lib –lpthread • Copy compiled binary to /usr2 directory • Specify filter application and arguments using configuration web or menu configuration www.sena.com 51 Serial Filter Application (4/4) Sample Filter and Output [email protected]:/mnt/flash/work# cp /mnt/flash/sample/filter/periodic_filter.c ./myfilter.c [email protected]:/mnt/flash/work# gcc -o myfilter myfilter.c -L/mnt/flash/lib -lpthread [email protected]:/mnt/flash/work# cp myfilter /usr2 [email protected]:/mnt/flash/work# editconf … -----------------------------------------------------------------------------Serial port configuration - Port #1 --> Filter application -----------------------------------------------------------------------------Select menu: 1. Filter application path name: /bin/ss.filter 2. Filter application arguments: <ESC> Back, <Enter> Refresh ---> 1 Enter a filter application full path name(ex: /bin/filter) ---> /usr2/myfilter -----------------------------------------------------------------------------… 1. Filter application path name: /usr2/myfilter 2. Filter application arguments: <ESC> Back, <Enter> Refresh ---> 2 Enter filter application arguments ---> 'You will see this msg every 1 sec' 1 www.sena.com Case Studies 1. Door Access Application (Customized) 2. Medical Application (Customized) 3. Bridge Monitoring System www.sena.com Door Access Application (Customized) www.sena.com 53 Door Access Application (Customized) • Target Device : RF-ID Card Reader • Application Details: – Customer has added a user customized filtering program that transmits only needed serial-based RF's to the management station through the SS110. – As a result, the time that is required to process visitor’s door access requests has been dramatically minimized. – Why SS instead of the PS? • Fast response required Local protocol parser application is required on the SS to reduce the network traffic www.sena.com 54 Bridge Monitoring System System Architecture SS110 www.sena.com 55 Bridge Monitoring System • Target Device : Gage length deformation sensors on a Railway Bridge • Application Details: – Long gage length deformation sensors (GPS) that are installed throughout a railway bridge to gain actionable information from the bridge – Why SS110? • Powerful logging capability (Syslog server) • Wireless LAN thru PCMCIA slot www.sena.com 56 Medical Application • Target Device: Medical Monitoring Device • Application Details: – Serial based medical devices are connected to Ethernet using the SS400/800 – Medical devices are reset remotely by sending “serial-break” signal thru the SS – “Serial-break” feature is implemented using the SS customization feature www.sena.com 57 Contact SENA SENA Technologies, Inc. [email protected] Phone:+82-2-529-7025 Fax: +82-2-573-7710 Web Address: http://www.sena.com 210 Yangjae-dong Seocho-gu Seoul 137-130, South Korea www.sena.com 58