Water Bath Units • Spaghetti Magic • Water Baths • Rethermalizers Front Rear Temperature Probe Low-water sensor Temperature Probe High-water sensor Low-water sensor High-water sensor Water-level sensors protect the cookpot from over or under fill.
Download ReportTranscript Water Bath Units • Spaghetti Magic • Water Baths • Rethermalizers Front Rear Temperature Probe Low-water sensor Temperature Probe High-water sensor Low-water sensor High-water sensor Water-level sensors protect the cookpot from over or under fill.
Water Bath Units • Spaghetti Magic • Water Baths • Rethermalizers Front Rear Temperature Probe Low-water sensor Temperature Probe High-water sensor Low-water sensor High-water sensor Water-level sensors protect the cookpot from over or under fill. 1C OPTIONAL BASKET LIFT 3C 24 V 71C TRANSFORMER GEAR MOTOR BASKET LIFT SHOWN IN UP POSITION 5C COM 71C 6C 8C POSITION TAP AS REQUIRED N.C. OPTIONAL AUTOFILL N.O. SOLENOID 24 VAC HIGH-LIMIT NC 11C C 24C COM B BASKET LIFT RELAY 24 VDC TEMPERATURE PROBE HIGH WATER SENSOR 8SMS Wiring Diagram 13C 2C 43C NO 7 A 44C NC 2 5 LOW WATER SENSOR CONTACTOR COIL 24 VAC 1C 1C COM 7C 4C 9C 14C 12C 10C SOUND DEVICE NC NC 1 2 3 4 5 1 2 3 4 5 HOT COM POWER IN 24 VAC GND NC HEAT NC 6 7 8 9 10 11 12 13 14 15 6 7 8 9 10 11 12 13 14 15 WATER FILL NO VOLTAGE WHEN HEATING GROUND WHEN FILLING 24 VAC WHEN OFF 24 VAC WHEN NOT FILLING COMPUTER CONTROL NC SD DO NOT MEASURE WATER LEVEL PROBES 3 TO 5 VOLTS WHEN SOUNDING BASKET LIFT 0 VOLTS WHEN BASKET IS DOWN TEMPERATURE PROBE NC 2 to 3 VOLTS DC NO DEPENDING ON VOLTAGE WATER TEMP. 13 to 17 VDC RELAY 13 TO 17 VDC WHEN BASKET IS UP ALL READINGS REFERENCED TO GROUND WITH THE COMPUTER OPERATING 8050377J EWBS with Pasta Package GWBS with Sauce and Pasta Package GREEN BLUE BROWN 200-240V 120 VAC CORDSET GEAR MOTOR GM GM 34C 108C BASKET LIFT SHOWN IN UP POSITION NC MICRO SWITCH COM 7C 21C NO 2C 13C 51C SPLICE SPLICE SPLICE CENTRIFUGAL SWITCH SPLICE 12C WHT BLK BASKET LIFT (OPTIONAL) 11C 9C 22C 6C 23C BLOWER 65C BASKET LIFT RELAY A 7 24 VDC C 6 4 VARISTOR 7 9 101C 2 5 B (OPTIONAL) 5 6 1 2 7 GAS VALVE C 8 25C 24V 3 5C 4 10C 43C 75C GWBS Wiring Diagram 5 6 7 8 1 2 3 4 4C 25V (GND) 25V 25V ALARM VALVE (GND) GND (BURNER) 25V IGNITION MODULE 77C ALARM VALVE 54C GND (BURNER) NO T E: FLAME SENSO R W IRE MUST BE CONNECTED TO THE SAME IGNITOR AS ITS MATCHING HIGH VOLTAGE LEAD IGNITION MODULE 24C 76C 57C HIGH TEMP WIRE 110C HIGH TEMP WIRE 66C 35C SOLENOID 24 VAC 50C LOW WATER SENSOR 59C TEMP PROBE HIGH WATER SENSOR 31C SOUND DEVICE 27C 29C RED TROUBLE LIGHT 71C 70C 1 55C SPARK MODULE (RIGHT) SPARK MODULE (LEFT) 2 3 NC 4 6 5 NC 7 8 9 NC COMPUTER 10 11 12 13 14 15 NC FAUCET SWITCH 17C EWBS w-Computer Wiring Diagram BASKET LIFT WIRING VIEWED FROM FRONT FAUCET SOLENOID 36C 31C 32C RED ORG OPTIONAL YLW TEMP PROBE BRN 29C YLW HIGH LEVEL PROBE OPTIONAL BASKET LIFT TO OPTIONAL BASKET LIFT OPTIONAL BASKET LIFT L1 28C L1 TO C1 PIN 13 LOW LEVEL PROBE TO C1 PIN 13 BASKET LIFT SHOWN IN UP POSITION GEAR MOTOR GEAR MOTOR 33C BASKET LIFT SHOWN IN UP POSITION 27C 34C N.C. 32C 25C 44C 23C 22C N.C. COM 27C 16C 5C 32C 2C 18C LEFT BASKET LIFT SWITCH 12 11 10 9 8 7 6 5 4 3 2 1 21C 19C 25C RIGHT BASKET LIFT SWITCH 22C 72C GRN/YLW 20C 44C 23C 30C 39C 54C 55C 40C 41C 42C LOAD 208/24V 208/12V LINE LINE 18C 16C 5C 2C 19C N.C. R 1 2 3 4 5 6 7 8 9 1H 95C WHT 93C BLK 57C 56C 3 2 1 B1 3H 4H 5H 6H 58C 59C 2 4 5 BLK 2H 21C 44C 20C BLK 6 WHT 15 PIN CABLE TO COMPUTER J4 PIN 1 J2 LOAD WHT J3 J5 N.O. N.O. C1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 COM 3 PIN 1 J1 32C HIGH-LIMIT 1 5 4 3 2 1 SOUND DEVICE COM HEAT CONTACTOR WATER SOLENOID HEAT CONTACTOR 13C 30C 44H 55H 66H 3 2 1 B1 31C 2 1 32C SKIM SWITCH CONTROLS CIRCUIT ELEMENT WIRING BLK PIN 1 OPTIONAL COLD WATER TAP COLD WATER TAP LEFT SIDE 17C EWBS w/Thermostat Wiring Diagram COLD WATER TAP RIGHT SIDE 2 1 3 SOLENOID 17C 36C 37C 34C 12C 18C 2 1 3 28C GRN/YLW 38C 11C 19C 1 35C 2 POWER SWITCH 43C 10C 3 9C 4 7C 5 25C C1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 HIGH LIMIT 42C 41C 6 COMMON 72C 7C GRN/YLW J1 44C 26C 39C 40C 20C PANEL LIGHT CONTACTOR COIL LOAD 24V 2 1 3 WHITE 24C RED 208V/240V LINE 6C 15C 95C WHT 1 BOIL SWITCH 3 POSITION 93C BLK 2 3 4C THERMOSTAT 4 3C J2 3 PHASE 4 WIRE 3 PHASE 3 WIRE 4H 2H 4H 1H 5H 3H 6H 5H 14C 6H 1 NC 2 NC J3 SOLENOID 13C 44H 55H 1H 2H3H 66H 44H 93C BLK 95C WHT 93C BLK 95C WHT N L3 L2 L1 2 1 3 66H 55H SKIM SWITCH N L3 L2 L1 LOW PROBE HIGH PROBE Rethermalizers • Heats vacuumed packed meats, sauces • Available in LP or Natural gas models • Prevents overcooking • Safeguarded against boilover • 18x24 cookpot area • Auto fill available FBR18 with digital controller Upper/Lower water-level sensor and probe/probe guard INSULATOR MUST SEAT IN HOLE BEFORE TIGHTENING NUT Screw-in water-level sensors protect against over or under filling