Water Bath Units • Spaghetti Magic • Water Baths • Rethermalizers Front Rear Temperature Probe Low-water sensor Temperature Probe High-water sensor Low-water sensor High-water sensor Water-level sensors protect the cookpot from over or under fill.

Download Report

Transcript Water Bath Units • Spaghetti Magic • Water Baths • Rethermalizers Front Rear Temperature Probe Low-water sensor Temperature Probe High-water sensor Low-water sensor High-water sensor Water-level sensors protect the cookpot from over or under fill.

Water Bath Units
• Spaghetti Magic
• Water Baths
• Rethermalizers
Front
Rear
Temperature
Probe
Low-water
sensor
Temperature
Probe
High-water
sensor
Low-water
sensor
High-water
sensor
Water-level sensors protect the cookpot from over or
under fill.
1C
OPTIONAL BASKET LIFT
3C
24 V
71C
TRANSFORMER
GEAR
MOTOR
BASKET LIFT
SHOWN IN
UP POSITION
5C
COM
71C
6C
8C
POSITION TAP
AS REQUIRED
N.C.
OPTIONAL
AUTOFILL
N.O.
SOLENOID
24 VAC
HIGH-LIMIT
NC
11C
C
24C
COM
B
BASKET LIFT RELAY
24 VDC
TEMPERATURE
PROBE
HIGH
WATER
SENSOR
8SMS Wiring Diagram
13C
2C
43C
NO
7
A
44C
NC
2
5
LOW
WATER
SENSOR
CONTACTOR COIL
24 VAC
1C
1C
COM
7C
4C
9C
14C
12C
10C
SOUND DEVICE
NC
NC
1
2
3
4
5
1
2
3
4
5
HOT
COM
POWER IN
24 VAC
GND
NC
HEAT
NC
6
7
8
9
10
11
12
13
14
15
6
7
8
9
10
11
12
13
14
15
WATER
FILL
NO VOLTAGE
WHEN HEATING
GROUND WHEN
FILLING
24 VAC WHEN OFF
24 VAC WHEN
NOT FILLING
COMPUTER CONTROL
NC
SD
DO NOT MEASURE
WATER LEVEL PROBES
3 TO 5 VOLTS
WHEN SOUNDING
BASKET LIFT
0 VOLTS WHEN
BASKET IS DOWN
TEMPERATURE
PROBE
NC
2 to 3 VOLTS DC
NO
DEPENDING ON VOLTAGE
WATER TEMP.
13 to 17 VDC
RELAY
13 TO 17 VDC
WHEN BASKET IS
UP
ALL READINGS REFERENCED TO GROUND WITH THE COMPUTER OPERATING
8050377J
EWBS
with Pasta Package
GWBS
with Sauce
and Pasta Package
GREEN
BLUE
BROWN
200-240V
120 VAC
CORDSET
GEAR
MOTOR
GM
GM
34C
108C
BASKET LIFT SHOWN
IN UP POSITION
NC
MICRO
SWITCH
COM
7C
21C
NO
2C
13C
51C
SPLICE
SPLICE
SPLICE
CENTRIFUGAL
SWITCH
SPLICE
12C
WHT
BLK
BASKET LIFT
(OPTIONAL)
11C
9C
22C
6C
23C
BLOWER
65C
BASKET LIFT RELAY
A
7
24 VDC
C
6
4
VARISTOR
7
9
101C
2
5
B
(OPTIONAL)
5
6
1
2
7
GAS
VALVE
C
8
25C
24V
3
5C
4
10C
43C
75C
GWBS Wiring Diagram
5
6
7
8
1
2
3
4
4C
25V
(GND)
25V
25V
ALARM
VALVE
(GND)
GND
(BURNER)
25V
IGNITION
MODULE
77C
ALARM
VALVE
54C
GND
(BURNER)
NO T E: FLAME SENSO R W IRE
MUST BE CONNECTED TO THE
SAME IGNITOR AS ITS MATCHING
HIGH VOLTAGE LEAD
IGNITION
MODULE
24C
76C
57C
HIGH TEMP WIRE
110C
HIGH TEMP WIRE
66C
35C
SOLENOID
24 VAC
50C
LOW
WATER
SENSOR
59C
TEMP PROBE
HIGH
WATER
SENSOR
31C
SOUND DEVICE
27C 29C
RED
TROUBLE
LIGHT
71C
70C
1
55C
SPARK MODULE (RIGHT)
SPARK MODULE (LEFT)
2
3
NC
4
6
5
NC
7
8
9
NC
COMPUTER
10
11
12
13
14
15
NC
FAUCET SWITCH
17C
EWBS w-Computer Wiring
Diagram
BASKET LIFT WIRING
VIEWED FROM FRONT
FAUCET SOLENOID
36C
31C
32C
RED
ORG
OPTIONAL
YLW
TEMP PROBE
BRN
29C
YLW
HIGH LEVEL PROBE
OPTIONAL BASKET LIFT
TO OPTIONAL
BASKET LIFT
OPTIONAL BASKET LIFT
L1
28C
L1
TO C1
PIN 13
LOW LEVEL PROBE
TO C1
PIN 13
BASKET LIFT
SHOWN IN
UP POSITION
GEAR MOTOR
GEAR MOTOR
33C
BASKET LIFT
SHOWN IN
UP POSITION
27C
34C
N.C.
32C
25C
44C 23C
22C
N.C.
COM
27C
16C
5C
32C
2C
18C
LEFT
BASKET LIFT SWITCH
12
11
10
9
8
7
6
5
4
3
2
1
21C
19C
25C
RIGHT
BASKET LIFT SWITCH
22C
72C
GRN/YLW
20C
44C
23C
30C
39C
54C
55C
40C
41C 42C
LOAD
208/24V
208/12V
LINE
LINE
18C
16C
5C
2C
19C
N.C.
R 1 2 3 4 5 6 7 8 9
1H
95C
WHT
93C
BLK
57C
56C
3 2 1 B1
3H
4H
5H
6H
58C
59C
2
4
5
BLK
2H
21C
44C 20C
BLK
6
WHT
15 PIN CABLE
TO COMPUTER
J4
PIN 1
J2
LOAD
WHT
J3
J5
N.O.
N.O.
C1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
COM
3
PIN 1
J1
32C
HIGH-LIMIT
1
5
4
3
2
1
SOUND
DEVICE
COM
HEAT
CONTACTOR
WATER SOLENOID
HEAT
CONTACTOR
13C
30C
44H
55H
66H
3
2 1 B1
31C
2
1
32C
SKIM SWITCH
CONTROLS
CIRCUIT
ELEMENT
WIRING
BLK
PIN 1
OPTIONAL COLD WATER TAP
COLD WATER TAP
LEFT SIDE
17C
EWBS w/Thermostat Wiring
Diagram
COLD WATER TAP
RIGHT SIDE
2
1
3
SOLENOID
17C
36C
37C
34C
12C
18C
2
1
3
28C
GRN/YLW
38C
11C
19C
1
35C
2
POWER SWITCH
43C
10C
3
9C
4
7C
5
25C
C1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
HIGH LIMIT
42C
41C
6
COMMON
72C
7C
GRN/YLW
J1
44C
26C
39C
40C
20C
PANEL LIGHT
CONTACTOR
COIL
LOAD
24V
2
1
3
WHITE
24C
RED
208V/240V
LINE
6C
15C
95C
WHT
1
BOIL SWITCH
3 POSITION
93C
BLK
2
3
4C
THERMOSTAT
4
3C
J2
3 PHASE 4 WIRE
3 PHASE 3 WIRE
4H
2H 4H 1H 5H 3H 6H
5H
14C
6H
1
NC
2
NC
J3
SOLENOID
13C
44H
55H
1H 2H3H
66H
44H
93C BLK
95C WHT
93C BLK
95C WHT
N
L3
L2
L1
2
1
3
66H
55H
SKIM SWITCH
N
L3
L2
L1
LOW PROBE
HIGH PROBE
Rethermalizers
• Heats vacuumed packed meats, sauces
• Available in LP or Natural gas models
• Prevents overcooking
• Safeguarded against boilover
• 18x24 cookpot area
• Auto fill available
FBR18 with
digital
controller
Upper/Lower water-level sensor and probe/probe
guard
INSULATOR
MUST SEAT IN
HOLE BEFORE
TIGHTENING
NUT
Screw-in
water-level
sensors
protect
against over
or under
filling