Smith Environmental Products Save 20 to 30%

On your air conditioning costs

Improving energy efficiency is the best short-term answer to today’s energy problems.

Until cleaner and sustainable sources of energy become available on a large scale, improving the energy efficiency of today’s systems is the best way to reduce co 2 emissions and save energy.

Air Conditioning has a huge potential for efficiency improvements

   Air conditioning is one of the largest energy consumers in the residential and industrial sector. Thousands of Air Conditioners put high demands on the electricity networks. On a smaller scale, air conditioning probably accounts for a significant part of your energy bill.

Many existing air conditioners use old and quite inefficient technology. Although improved technology has become available in more expensive systems (e.g. inverter technology), the payback time of these systems is still very long.

Instead of investing a lot of money into an expensive new system, there is an easy and affordable way to improve the energy efficiency of your unit…

It is a retrofit product that adds intelligence to air-conditioning systems, which saves KWh and extends compressor life.

* Sensor driven software algorithms designed to detect thermodynamic saturation and optimize compressor run times *Provides anti-short cycling; mandatory compressor off time after thermostat reaches set point (3 minutes) or loss of power (1 minute).

*Reduces equipment operating temperature and prevents evaporator freeze-over by properly cycling the compressor.

*Constantly adapting its settings to inside demand requirements and outside weather conditions.

*AircoSaver is engineered and Manufactured in Germany for 9 plus years.

How does the AircoSaver Work?

First we will see what the shortcomings are of a typical AC System Then let’s take a look at what a typical cooling cycle with excess capacity looks like Last, let’s find out how the AircoSaver compensates these shortcomings.

Shortcomings of a Typical AC System

  When switched on, typical air conditioning systems operate continuously until the room thermostat senses the desired temperature and turns the system off. As the room warms up, the thermostat switches the air conditioner back on and the cycle repeats Air conditioning systems are usually dimensioned to cope with the extreme cooling demands of the few hottest days of the year (plus a safety margin).

most of the time.

However, in most operational conditions, this maximum output is not required and the system is oversized. So running the system continuously until the room thermostat switches it off means that the system operates with excess capacity

A typical cooling cycle with excess capacity looks like this:

   When the cycle starts, the compressor pushes cooling energy into the heat exchanger which acts as an energy storage. At this stage, the system works with high efficiency because compressors operate most efficiently when fully loaded.

In normal weather conditions, the energy storage Is soon fully “charged up”. From this point onwards, the compressor provides more cooling energy than the heat exchanger can take up (thermodynamic saturation).

Running the compressor beyond this stage does NOT increase the cooling effect any more.

The AircoSaver compensates these shortcomings and adds intelligence to your AC Systems

   

This is where the AircoSaver cuts in

. It’s sensor driven software algorithms are designed to detect thermodynamic saturation and to optimize the compressor accordingly.

When overcapacity is detected, the AircoSaver switches the compressor off and avoids inefficient overcooling.

Your unit switches into “saver mode”. The fan keeps running and your system makes maximum use of the stored cooling energy in the heat exchanger. Once the stored energy is used up, the compressor can work efficiently again and is switched back on.

The set room temperature is reached without the inefficient parts of the cooling cycle. This results in significant energy savings without compromising cooling comfort.

Since the correct point to switch the compressor varies from unit to unit and changes with different weather conditions, the AircoSaver is constantly adapting its settings to ensure efficient operation of your air conditioning system at all times.

A very simple AircoSaver Analogy

          Imagine a sink with a drain and tap The tap can only be turned full on or completely off. Nothing in-between.

The tap usually can deliver more water than the drain can take (partial loads).

So when the tap is turned on, the water in the sink will rise The aim is to achieve a constant flow out of the drain without spilling any water.

The water level rises and rises At one stage the water will start to spill over the sink (thermodynamic saturation) At this stage the tap can be turned off and the water in the sink will continue to flow out of the drain.

Later, the tap is turned on again before the sink is empty and the sink fills up again.

So, no spillage-that means best efficiency.

Package Units (RTU)

Split Systems

PTAC

Window Units

Wall Units

Approximate increase in efficiency with the installation of the AircoSaver

Manufacturers

Actual EER 9 10 11 12 13 14

20 %

New EER 11 13 14 15 16 18

Savings Potential 30 %

New EER 13 14 16 17 19 20

40 %

New EER 15 17 18 20 22 23

50 %

New EER 18 20 22 24 26 28 This table shows the equivalent increase in the efficiency (Energy Efficiency Rate “EER”) of Air Conditioning installed after AircoSaver. For example, an AC with an EER of 10, taking AircoSaver with savings of 30%, increases its efficiency to an EER of 14.

Domino’s store# 6711 5 Ton AC before & after Airco Saver

No Airco Installed

File C:\PowerSight\Dominos 5ton Before Airco.log File C:\PowerSight\Dominos 5ton After Airco.log Test began at 6/22/08 12:30:00

With AircoSaver Installed

Test began at 6/21/08 10:30:00 Test ended at 6/23/08 12:15:00 Test ended at 6/22/08 10:00:00

Measurement

Voltage, A Phase, Ave: Voltage, B Phase, Ave: Voltage, C Phase, Ave: Current, A Phase, Ave: Current, B Phase, Ave: Current, C Phase, Ave: Total True Power: Total VA Power: Energy, A Phase: Energy, B Phase: Energy, C Phase: Energy, Total Elapsed:

Energy, estimated per month:

Cost, Total Elapsed:

Cost, estimated per month: Before

121.6 122.0 121.1 9.0 10.9 11.5 3347.0 3812.4 22.456 29.534 27.502 79.491

2445.0

$7.55

$232.28 After Units

121.4 122.0 121.0 7.1 9.4 10.0 2780.7 volts volts volts amps amps amps Watts 3227.6 VA 17.321 KWH 25.232 KWH 22.795 KWH 65.347 KWH

2031.3 KWH

$6.21

$192.97 Change

-0.2 -0.1 -0.1 -1.9 -1.5 -1.5 -566.3 -584.8 -5.135 -4.302 -4.707 -14.144

-413.7

$-1.34

$-39.31 %Change

-0.2 % -0.1 % -0.1 % -20.9 % -14.0 % -13.2 % -16.9 % -15.3 % -22.9 % -14.6 % -17.1 % -17.8 %

-16.9 %

-17.8 %

-16.9 %

(at $0.095/KWH)

Peak Demand (15min):

Demand Period: Peak Ave VA: Peak VA Period: Data Logging Eq: PowerSite PS300 by Summit Technology, Inc Report Software: PowerSite Manager version 3.1Z10 Report Prepared By: Fred Trejo SEP 9330 Corporate Dr, Suite 510 Selma, TX 78154 Phone: Email:

6611.2

6/22/08 14:15:00 7400.8 6/22/08 14:15:00 210-386-1447 [email protected]

5040.0 Watts

6/21/08 14:45:00 5724.0 VA 6/21/08 14:45:00

-1571.2

-1676.8

-23.8 %

-22.7 %

DATA

Average Outside Temp Average Outside RH Average Heat Index KW Demand Rate Average KWh/day

BEFORE AIRCO INSTALL (June 2008)

80.2

65.5

83 29 442.7

AircoSaver Savings Domino’s Store # 6711 San Antonio, TX AFTER AIRCO INSTALL (July 2008)

82.3

AFTER AIRCO INSTALL ( Aug 2008)

81.4

67.0

86 27 395.2

71.8

86 27 389

Change

1.6

3.9

3.0

-2.0

-50.6

% Change

2.06% 5.95% 3.61% -6.90% -11.43% *KWh per month 13,281 *Cost per month @ $.095 per KWh Projected Annual Savings $1,261.70

$15,140.34

* Per month data is based on a 30 day month

11,856 $1,126.32

$13,409.82

11,670 $1,108.65

-1,518 -$144.21

-$ 1730.52

-11.43% -11.43% -11.43%

COMMENTS:

The average temperature, relative humidity and heat index were all higher after the AircoSavers were installed which lowered the overall savings. Also, the KW Demand savings was almost 7%, but was not figured into the savings listed above.

The data above was compiled from the following sources: CPS Energy monthly electric bills for Jun, Jul, and Aug 2008. The weather data was downloaded from weatherunderground.com station KTXSANAN78.

Call SEP for a copy of this report

90 Min. Before & After test In 24 hr. operational site Measurement Voltage, Phase 1, Ave: Voltage, Phase 2, Ave: Current, Phase 1, Ave: Current, Phase 2, Ave: True power, Phase 1, Ave: True power, Phase 2, Ave: Total True Power Ave: VA Power, Phase 1, Ave: VA Power, Phase 2, Ave: Total VA power Ave: Energy, Total Elapsed: Energy, estimated per month: Cost, Total Elapsed: Cost, estimated per month: Before 119.1

115.5

11.9

12.1

1288.1

1262.6

2551.1

1420.2

1395.0

2815.6

3.78348

1863.3

$0.66

$326.07

AircoSaver Test 3 ton Bard wall unit in Telecom Hut Dallas, TX 06-09-09

After Units 118.7

117.0

9.4

9.3

1015.6

984.7

Volts Volts Amps Amps Watts Watts Change -0.4

1.4

-2.5

-2.7

-272.5

-277.9

2000.6

1117.1

1087.8

Watts VA VA -550.5

-303.2

-307.1

2205.2

2.967

1461.2

$0.52

$255.71

VA KWH KWH -610.3

-0.816

-402.1

$-0.14

$-70.36

% Change -0.4% 1.2% -20.9% -22.8% -21.2% -22.0% -21.6% -21.3% -22.0% -21.7% -21.6% -21.6 % -21.6% -21.6%

Thermostat

Y1

Intercept Y1 from thermostat and re-route through AircoSaver AircoSaver Installation AircoSaver Supply 24V to AircoSaver Control Board 24 Volts Blower Install sensor in supply Air Flow or on evaporator (whichever is coldest) Evaporator

Supply Air Y1

Return Air Compressor

Page 5 of 5 * Contact SEP for a copy of this report

Calculation Methods

At each site, air conditioner supply voltage was recorded. Air conditioner power was derived from the formula- (measured volts X measured amps X assumed power factor of .85) = power. Only one site, SD0364 was supplied with three phase power for air conditioners. The three phase power conversion factor of 1.732 was used to calculate power consumption at that site. Pre period average hourly power consumption was compared to post period average hourly power consumption and the result was annualized to determine annual energy savings. No air conditioner performance corrections were made for increased ambient (external) temperature. At eight of the nine sites average temperature during the post period was higher than during the baseline test period. An examination of compressor kW VS ambient temperature showed little difference.

Project Results and Discussion

Average hourly power savings was calculated for each site and extrapolated to annual energy savings. Overall air conditioning savings was 20% of baseline air conditioner energy consumption, and averaged 7071 kWh for the nine sites. Energy savings averaged 6.8% of site total energy consumption.

The Aircosaver control system may be incentivized through the Standard Performance Contract Program at nine cents per annual kWh saved. The incentive is limited to ½ the installed cost, or the calculated incentive, whichever is less.

At an average site electric cost of 14.4 cents/kWh Annual energy savings for installing the AircoSaver at each site is around $1,000 per year.

AircoSaver Summary Data From Each Test Site Cell Site Total Before Airco Amp hrs.

Total After Airco Amp hrs.

Avg Before inside Temp Avg After Inside Temp Avg Before Outside temp Avg After Outside Temp Avg Before kW Avg After kW % HVAC energy savings Total kWh saved per year SD0329 8229 6705 71.9

72.7

73 80.5

4.92

4.01

18% 7972 SD0332 3165 2557 75.5

75.4

70 73 3.29

2.66

19% 5519 SD0364 3904 3116 78.5

79 73 84 3.49

2.78

20% 6220 SD0368 9745 7564 74.07

73.73

74.36

73.78

5.83

4.52

22% 11427 SD0385 8579 7061 74.2

75 71 80 4.38

3.61

18% 6745 SD0402 4543 3737 77.3

76.5

70 72 2.63

2.16

18% 4117 SD0432 6827 4940 7502 75.4

70 75 3.33

2.62

21 % 6220 SD0442 8194 6399 75 75 73.7

76.9

4.32

3.37

22% 8322 SD0454 7155 5669 78.2

78.8

70 79 3.9

3.09

21% 7096 Average 6705 5305 901 76 72 77 4.01

3.20

20% 7071

Test report issued September 18, 2009 by CR Harmstead, SDGE and Adam Fitzpatrick, ENERGE Corporation: C.Rocky Harmstead [email protected]

Adam Fitzpatrick – [email protected]

Major Wireless Carrier Cell Site Evaluation of AircoSaver HVAC Savings

Johnny E. Smith President [email protected]

Fred Trejo VP Tech Support [email protected]

Ph # 210-386-1447 Solving Problems $aving Money 9330 Corporate Dr.

Suite # 510 Selma, TX 78154 Ph: 210-651-6663 Fax: 210-651-5595