No Slide Title
Download
Report
Transcript No Slide Title
GE Interlogix
Kalatel Division
Product Update
KTD-405 Programming
& Standard Operations
KTD-405 Keypad
Programming
KTD-405 keypad (Supervisor Programming)
Boot-Up Screen
KEYPAD ADDRESS: 99
KEYPAD 99
KTD-405 keypad (Supervisor Programming)
Default display after applying power
CAMERA --MONITOR 1
KTD-405 keypad (Programming)
Navigating the menus
Key
Function
Displays the next menu
Displays the previous menu
Scrolls up when indicated by in the menus
Scrolls down when indicated by in the menus
Scrolls right when indicated by in the menus
Scrolls left when indicated by in the menus
Scrolls up, down, left or right when indicated by , , , in the menus
seq
Advances menus; exits menus if held for 3 seconds
KTD-405 keypad (Programming)
Menus that were not available in the first releases of software
are indicated by two beeps and the following display:
NOT IMPLEMENTED
Supervisor Programming
KTD-405 keypad (Supervisor Programming)
To Access Programming:
Press and hold the
key
The unit will beep and show the following display
ENTER PROGRAMMING
CODE:
Remote device programming must be accessed separately.
Supervisor programming password is 1,4,7,6,
Also includes All user programming
seq
KTD-405 keypad (Supervisor Programming)
Resetting the Factory Defaults
The first menu to display will be this one.
RESET TO DEFAULTS?
<+>=YES <->=NO
NO
NEXT
Press to advance to the next menu and to return to the
previous menu at any time without changing any existing
parameters
KTD-405 keypad (Supervisor Programming)
If you pressed “+” (yes):
The next display will show:
1=RESET ALL BUT TITLES
2=RESET ALL
Followed by:
ARE YOU SURE?
<+>=YES <->=NO
NEXT
Followed by:
INITIALIZING DEFAULTS
PLEASE WAIT
The keypad will advance to the next menu automatically
KTD-405 keypad (Supervisor Programming)
Setting The Keypad Address
The address is a “user defined” two-digit number
The address must be from 10 to 99
Each device on the RS-485 network must have a unique address
KEYPAD ADDRESS: 99
(01-99)
NEXT
Address 99 is automatically assigned when the keypad is first
connected and will remain unless changed by the user
Entering an address that is already used temporarily displays:
ADDRESS NOT AVAILABLE
Select or to skip over this menu
KTD-405 keypad (Supervisor Programming)
Backward Compatibility?
If the KTD-405 is being used in a system with:
Existing ProBridges
Existing CBR-KB3 or CBR-KB3/J keypads
KB3 PTZ PROTOCOL?
<+>=YES <->=NO
NO
NEXT
Select YES to allow the KTD-405 to communicate properly with
these devices.
Select or to skip over this menu
KTD-405 keypad (Supervisor Programming)
Allow Remote Programming by user?
If the KTD-405 is being used in a system with:
Matrix Switchers or Multiplexers
Alarm Monitoring Equipment
Programmable Dome Cameras or Receivers
ENABLE REMOTE PRGMG? YES
<+>=YES <->=NO
NEXT
Select YES to allow the user to enter the seq
9,5,1,
and program these devices
Select or to skip over this menu
password
KTD-405 keypad (Supervisor Programming)
Programming Keypad Titles
A keypad title can be up to 14 characters including:
A – Z and 0 - 9
Keypads with titles can use the “Seize Control” option
Supervisors can seize camera sites, multiplexers, VCRs, etc.
Supervisors can seize an entire zone in the ZONE mode
KEYPAD TITLE:
<>
NEXT
Use the joystick or these buttons to program the title
= ,
= ,
= ,
= ,
Select or to skip over this menu
KTD-405 keypad (Supervisor Programming)
Changing the SEIZE CONTROL code
Use the number keys to enter the new code
The keypad will advance to the next menu when the last digit is
entered
SEIZE CONTROL CODE: 8642
USE NUMBER KEYS
NEXT
Select or to skip over this menu
KTD-405 keypad (Supervisor Programming)
Changing the SEIZE CONTROL time
Use the number keys to enter the new time
This is the number of minutes of inactivity before the keypad will
exit the seize control mode
SEIZE CONTROL TIME: 5
(1-10) MINUTES
NEXT
Select or to skip over this menu
KTD-405 keypad (Supervisor Programming)
Restricting access to presets
Use the number keys to enter the new limit
This is the lowest preset number a user may change
LOWEST USER PRGMD PRESET
(01-64) 58
NEXT
Select or to skip over this menu
KTD-405 keypad (Supervisor Programming)
Programming the SOFT keys
This feature is not yet implemented
PROGRAM SOFT KEYS?
<+>=YES <->=NO
NEXT
Select -, or to skip over this menu
Pressing + displays the following message:
NOT IMPLEMENTED
KTD-405 keypad (Supervisor Programming)
Programming the ACCESS codes
This feature is not yet implemented
CHANGE ACCESS CODES?
<+>=YES <->=NO
NEXT
Select -, or to skip over this menu
Pressing + displays the following message:
NOT IMPLEMENTED
User Programming
KTD-405 keypad (User Programming)
To Access User Programming:
Press and hold the
key
The unit will beep and show the following display
ENTER PROGRAMMING
CODE:
User programming password is 5,7,9,
seq
KTD-405 keypad (User Programming)
Changing the Operating Mode
Two choices are available:
Digiplex
Zone
OPERATING MODE: DIGIPLEX
<,>=SELECT
NEXT
Use the joystick or these buttons to select the mode
= ,
=
Select or to skip over this menu
KTD-405 keypad (User Programming)
DigiPlex mode Menus
Setting the system size
Enter the highest camera number in your system
SYSTEM SIZE:
<CAMERAS> 511
NEXT
Select or to skip over this menu
KTD-405 keypad (User Programming)
DigiPlex mode Menus
Setting the system size
Enter the highest monitor number in your system
SYSTEM SIZE:
<MONITORS> 64
NEXT
Select or to skip over this menu
KTD-405 keypad (User Programming)
DigiPlex mode Menus
Setting the system size
Enter the highest multiplexer number in your system
SYSTEM SIZE:
<MPLXS>
32
NEXT
Select or to skip over this menu
KTD-405 keypad (User Programming)
DigiPlex mode Menus
Setting the system size
Enter the highest VCR number in your system
SYSTEM SIZE:
<DSR/VCR> 32
NEXT
Select or to skip over this menu
KTD-405 keypad (User Programming)
DigiPlex mode Menus
Setting the system size
Enter the highest preset number in your system
SYSTEM SIZE:
<PRESETS> 63
NEXT
Select or to skip over this menu
KTD-405 keypad (User Programming)
DigiPlex mode Menus
Restricting system access
This menu restricts access to specified cameras
CAMERA 000 ACCESS?
<+>=YES <->=NO
YES
NEXT
Use the joystick or these buttons to select the camera
= , =
Select or to skip over this menu
KTD-405 keypad (User Programming)
DigiPlex mode Menus
Restricting system access
This menu restricts access to specified cameras
CAMERA 000 ACCESS?
<+>=YES <->=NO
YES
NEXT
Use the joystick or these buttons to select the camera
= , =
Select or to skip over this menu
KTD-405 keypad (User Programming)
DigiPlex mode Menus
Restricting system access
This menu restricts access to specified monitors
MONITOR 01 ACCESS?
<+>=YES <->=NO
YES
NEXT
Use the joystick or these buttons to select the monitor
= , =
Select or to skip over this menu
KTD-405 keypad (User Programming)
DigiPlex mode Menus
Restricting system access
This menu restricts access to specified recorder
DSR/VCR 01 ACCESS?
<+>=YES <->=NO
YES
NEXT
Use the joystick or these buttons to select the recorder
= , =
Select or to skip over this menu
Pressing “+” displays this menu:
VCR 01 MATRIX INPUT:
000 <0=NONE>
NEXT
Enter a number from 0 to 511, or 0 for NONE or
Select or to skip over this menu
KTD-405 keypad (User Programming)
DigiPlex mode Menus
Restricting system access
This menu restricts access to specified multiplexer
MPLX 01 ACCESS?
<+>=YES <->=NO
YES
NEXT
Use the joystick or these buttons to select the multiplexer
= , =
Select or to skip over this menu
KTD-405 keypad (User Programming)
DigiPlex mode Menus
If you pressed “+” (yes):
The next display will show:
MPLX01
BRAND CBR DVMRe
<,>=SELECT
NEXT
Followed by:
MPLX 01 MATRIX INPUT?
000 <0=NONE
NEXT
Followed by:
SELECT MAX OUTPUTS:
<,>=SELECT
02
NEXT
The keypad will advance to the next multiplexer menu
automatically
KTD-405 keypad (User Programming)
Programming the monitor offset
DigiPlex mode Menus
Enter a number for the offset needed in your system
MONITOR OFFSET
NUMBER: 0
NEXT
Select or to skip over this menu
KTD-405 keypad (User Programming)
DigiPlex mode Menus
Queuing and announcing call-ins
If you select “+” in this display:
ANNUNCIATION?
<+>=YES <->=NO
NO
NEXT
You need to select either SINGLE or MULTIPLE tone here:
CALL TONE TYPE? MULTIPLE
<,>=SELECT
NEXT
Also specify a monitor to display the queued calls:
SPOT MONITOR NUMBER:
<0=UNASSIGNED>
0
NEXT
Select or to skip over this menu
KTD-405 keypad (User Programming)
DigiPlex mode Menus
End of menus notification
Pressing from the previous menu will cause the keypad to
display this message:
PRESS <SEQ> FOR 3
SECONDS TO EXIT
Select or press and hold
seq
for 3 seconds to exit the menus
KTD-405 keypad (User Programming)
Changing the Operating Mode
Two choices are available:
DigiPlex
Zone
OPERATING MODE:
<,>=SELECT
ZONE
NEXT
Use the joystick or these buttons to select the mode
= ,
=
Select or to skip over this menu
KTD-405 keypad (User Programming)
Programming the Mode label
Zone mode Menus
This menu allows you to select one of several labels for the LCD
display during normal operations
LCD DISPLAY LABEL: ZONE
<,>=SELECT
NEXT
Selections Include:
ZONE, MPLX, DVMR, TERR, BLDG
FLR, DEPT, STA, SITE, AREA
Select or to skip over this menu
KTD-405 keypad (User Programming)
Programming the zone titles
Zone mode Menus
This menu allows you to select a title to display when the
specified zone is being accessed.
ENTER ZONE ADDRESS: 01
(01-16)
NEXT
Select or to skip over this menu
Enter a two-digit code and the keypad will advance to the
following menu automatically
ZONE 01 TITLE:
<>
(01-16)
NEXT
Program the label characters the same way as keypad titles
Select or to skip over this menu
KTD-405 keypad (User Programming)
Programming the Zone type
Zone mode Menus
This menu allows you to identify the specific device that makes
up a zone:
ZONE 01 HUB: CBR DVMRe
<,>=SELECT
NEXT
Selections Include:
CALIBUR MMX, CBR DVMRe, CBR TRIPLEX,
CBR DUPLEX, CBR SIMPLEX, MATRIX SWCH,
Select or to skip over this menu
KTD-405 keypad (User Programming)
Zone mode Menus
Setting the zone size (monitors)
This menu restricts access only to available zone monitors
ZONE 01 MON. OUTPUTS?
01 TO 02
NEXT
Use the number buttons to set the number of monitors
Select or to skip over this menu
Setting the zone size (cameras)
This menu restricts access only to available zone cameras
Choices include 4, 9, 10, 16 and 32
ZONE 01 CAM. INPUTS?
<,>=SELECT
16
NEXT
Use the joystick or these buttons to select the mode
Select or to skip over this menu
= ,
=
KTD-405 keypad (User Programming)
Programming zone access privileges
Zone mode Menus
Program the cameras that this keypad can access:
ZONE 1 CAM 01 ACC?
<+>=YES <->=NO
YES
NEXT
Program the monitors that this keypad can access:
ZONE 1 MON 01 ACC?
<+>=YES <->=NO
YES
NEXT
Program user access to the zone’s recorder :
ZONE 1 RECORDER ACC? YES
<+>=YES <->=NO
NEXT
You should deny access unless you have a Triplex or MMX
connected to a VCR using sub-macros.
KTD-405 keypad (User Programming)
If the Zone type is set to MATRIX SWCH:
Zone mode Menus
The zone size and access menus displays are slightly different
ZONE 02 HUB: MATRIX SWCH
<,>=SELECT
NEXT
KTD-405 keypad (User Programming)
Zone mode Menus
Programming zone size
Program the first camera input number for this zone:
SELECT START INPUT: 032
<,>=SELECT
NEXT
Program the number of monitors for this zone:
ZONE 02 MON. OUTPUTS:
01 TO 16
NEXT
Program the number of camera inputs on this zone:
ZONE 02 CAM. INPUTS: 64
<,>=SELECT
NEXT
Choices include 4, 9, 10, 16 and 32
KTD-405 keypad (User Programming)
Programming zone access privileges
Zone mode Menus
Program the cameras that this keypad can access:
ZONE 02 CAM 01 ACC?
<+>=YES <->=NO
YES
NEXT
Program the monitors that this keypad can access:
ZONE 02 MON 01 ACC?
<+>=YES <->=NO
YES
NEXT
Program user access to the zone’s recorder :
ZONE 02 RECORD ACC? YES
<+>=YES <->=NO
NEXT
You should deny access unless you have a Triplex or MMX
connected to a VCR using sub-macros.
KTD-405 keypad (User Programming)
Zone mode Menus
Queuing and announcing call-ins
If you select “+” in this display:
ANNUNCIATION?
<+>=YES <->=NO
NO
NEXT
You need to select either SINGLE or MULTIPLE tone here:
CALL TONE TYPE? MULTIPLE
<,>=SELECT
NEXT
Also specify a monitor to display the queued calls:
SPOT MONITOR NUMBER:
<0=UNASSIGNED>
0
NEXT
Select or to skip over this menu
KTD-405 keypad (User Programming)
Zone mode Menus
End of menus notification
Pressing from the previous menu will cause the keypad to
display this message:
PRESS <SEQ> FOR 3
SECONDS TO EXIT
Select or press and hold
seq
for 3 seconds to exit the menus
Remote Programming
KTD-405 keypad (Remote Programming)
To Access Remote Programming:
Press and hold the
key
The unit will beep and show the following display
ENTER PROGRAMMING
CODE:
User programming password is 9,5,1,
seq
Correct password entry will cause the following display:
1=SWITCHER/MPLX 2=ALARMS
3=CAMERA/RCVR
EXIT
Each selection generates a different set of menus
KTD-405 keypad (User Programming)
Switcher/Multiplexer Programming
Switcher/Mux Menus
Identify the device to be programmed
1=440
2=CALIBUR
3=340/348
BACK
If you select “1” (440) enter the monitor number to use for
programming the switcher
ENTER MONITOR NUMBER:
(1-64)
BACK
The keypad will display this message
SEE MONITOR FOR MENUS
HOLD SEQ <3 SEC> TO EXIT
KTD-405 keypad (User Programming)
Identify the device to be programmed
1=440
Switcher/Mux Menus
2=CALIBUR
3=340/348
BACK
If you select “2” (CALIBUR) enter the RS-485 address of the
unit to be programmed
ENTER CALIBUR ADDRESS:
(1-32)
BACK
The keypad will display this message
SEE MONITOR FOR MENUS
HOLD SEQ <3 SEC> TO EXIT
KTD-405 keypad (User Programming)
Identify the device to be programmed
1=440
Switcher/Mux Menus
2=CALIBUR
3=340/348
BACK
If you select “3” (340/348) enter the monitor number to use for
programming the switcher
ENTER MONITOR NUMBER:
(1-64)
BACK
The keypad will display this message
SEE MONITOR FOR MENUS
HOLD SEQ <3 SEC> TO EXIT
KTD-405 keypad (User Programming)
Alarm Programming
The keypad will display this message
SEE MONITOR FOR MENUS
HOLD SEQ <3 SEC> TO EXIT
Alarm Menu
KTD-405 keypad (User Programming)
Camera/Receiver Programming (DigiPlex)
Camera/Receiver
Menus
Identify the device to be programmed
1=CYBERDOME
3=AUXILIARY
2=PTZ
BACK
If you select “1” (CYBERDOME) enter the camera address to
be programmed
ENTER CYBERDOME SITE
NUMBER
BACK
The keypad will display this message
SEE MONITOR FOR MENUS
HOLD SEQ <3 SEC> TO EXIT
KTD-405 keypad (User Programming)
Camera/Receiver Programming (Zone)
Camera/Receiver
Menus
Identify the device to be programmed, AND Make sure you
have selected the Zone before you enter programming
1=CYBERDOME
2=PTZ
3=AUXILIARY
BACK
If you select “1” (CYBERDOME) enter the camera address to
be programmed (address must be within the zone)
ENTER ZONE
NUMBER__
1
CAMERA
BACK
The keypad will display this message
SEE MONITOR FOR MENUS
HOLD SEQ <3 SEC> TO EXIT
KTD-405 keypad (User Programming)
PTZ OR Auxiliary Programming
If you select “2” or “3” from this menu
1=CYBERDOME
2=PTZ
3=AUXILIARY
BACK
The keypad will display this message
NOT IMPLEMENTED
PTZ/Auxiliary Menus
Standard Operation
KTD-405 keypad (Standard Operation)
Default display after applying power
DigiPlex mode
CAMERA --MONITOR 1
Zone Mode
ZONE – ZONE TITLE
CAMERA --
MONITOR -
KTD-405 keypad (Standard Operation)
Accessing System Information:
mon
Press and hold the
key to display the system information
The keypad will display
KEYPAD ADDRESS: 99
KEYPAD 99
NEXT
Use or to move between these additional system information
displays
VERSION
0.1.07
Dec 20 2001 09:32:44
CAM MN MX RC PS QS MO AT
511 64 32 32 63 58 00
W
KTD-405 keypad (Standard Operation)
Accessing Help displays:
Press
esc
+ mon
to display the Help menu
In the help menus:
Pressing any key displays that key’s function
esc
+ “key” displays that key’s shifted function
The help display will cease display after 10 seconds of inactivity
KTD-405 keypad (Standard Operation)
Selecting a monitor:
There are two ways:
Enter the monitor number with any preceding zeroes
Example: 1 (systems with less than 10 cameras)
Example: 01 (systems with more than 9 cameras)
Enter the monitor number, then press
Example: 1 +
CAMERA ---
MONITOR 1
KTD-405 keypad (Standard Operation)
Selecting a camera:
There are two ways:
Enter the camera number with any preceding zeroes
Example: 3 (systems with less than 10 cameras)
Example: 03 (systems with less than 100 cameras)
Example: 003 (systems with more than 99 cameras)
Enter the camera number, then press
Example: 3 +
CAMERA ---
MONITOR 1
KTD-405 keypad (Standard Operation)
Controlling a camera:
Select the camera to be controlled
CAMERA 003
MONITOR 1
Pan, Tilt and Zoom can be controlled by the joystick
Up/Down for Tilt control
Left/Right for Pan control
Twist the joystick for Zoom or use
the
+zoom Use the +iris-
and
+focus-
key
keys for these functions
KTD-405 keypad (Standard Operation)
Setting a preset:
Position the camera
Press the Store key
store
Enter the preset number in one of three ways:
Enter the two-digit number (Ex. 05 or 16)
Use the AUX-1, AUX-2, AUX-3 or AUX-4 keys for 58-61 aux 1
Use
and
for presets 62 and 63 (left and right Auto-Pan
limits. Presets 62 and 63 can not be set by entering the two-digit
numbers. On with these two keys
and
.
KTD-405 keypad (Standard Operation)
Programming a Groups (salvos) and Tours:
Requires a RS-485 connection and zone selected
DigiPlex
Mode
Requires Switcher monitor groups to be previously programmed
Press Storestore
seq
+ Sequence
This menu will display:
ENTER MONITOR GROUP
(1-64)--
OR <TOUR>
Enter a number from 1 to 64 calls that group of cameras on the
monitors
tour
If you press the Tour
key the following menu is displayed:
ENTER GROUP SEQUENCE
(1-12)--
Enter a number from 1 to 12 TO START that group sequence on the
monitors
KTD-405 keypad (Standard Operation)
Controlling a recording device:
Digiplex Mode
Requires a KTD-93 interface (RS-422 to RS-232)
Key
Function DSR/VCR
Function DVMRe
Starts recording
Starts recording
Stops record or playback
Stops record or playback
Starts playback
Starts playback
Pauses playback
Pauses playback or live mode
Fast Forward
Fast Forward
Fast Reverse (rewind)
Fast Reverse (rewind)
Frame advance
Play forward (from reverse play)
Depends on device (DSR/VCR)
Frame advance (in pause mode)
Frame reverse
Play reverse (from forward play)
Depends on device (DSR/VCR)
Frame reverse (in pause mode
n/a
2X digital zoom toggle
n/a
Activates play and displays search menu
KTD-405 keypad (Standard Operation)
Controlling a recording device:
Digiplex Mode
Requires a KTD-93 interface (RS-422 to RS-232)
Key
Function DSR/VCR
Function DVMRe
In Play or Pause modes:
↻ Twist right = variable rate forward
↺ Twist left = variable rate reverse
Skip forward 2MB (about 15 sec.)
Joystick
Skip backward 2MB (about 15 sec.)
↻ Twist right = variable rate forward
Fast Forward
↺ Twist left = variable rate reverse
Fast Reverse (rewind)
Return to center position resumes
pause mode
In 2X Zoom mode:
functions
Tilt up
Tile down
Pan right
Pan left
KTD-405 keypad (Standard Operation)
Controlling a multiplexer:
Zone Mode
Requires RS-485 connection
Key
Function VCR/DSR
Function Multiplexer
Starts recording
Starts recording
Stops record or playback
Stops record or playback
Starts playback
Starts playback
Pauses playback
Pauses playback or live mode
Fast Forward
Fast Forward
Fast Reverse (rewind)
Fast Reverse (rewind)
Frame advance
Frame advance (in pause mode)
Frame reverse
Frame reverse (in pause mode
2X digital zoom toggle
n/a
Activates play and displays search menu
n/a
Multiplexer must support sub-macro VCR interface
KTD-405 keypad (Standard Operation)
Controlling a multiplexer:
Zone Mode
Requires a RS-485 connection
Key
Function Multiplexer
Function DSR/VCR
In Play or Pause modes:
↻ Twist right = variable rate forward
Joystick
↺ Twist left = variable rate reverse
n/a
In 2X Zoom mode:
Tilt up
Tile down
functions
Pan right
Pan left
Multiplexer must support sub-macro VCR interface
KTD-405 keypad (Standard Operation)
Programming a multiplexer AutoList sequence:
Requires a RS-485 connection and zone selected
Press Store store
Press Sequence
Zone Mode
seq
This menu will display:
ENTER SEQUENCE CAMERA
CANCEL
DONE
Enter the first camera number in the sequence
Wait the desire amount of time you want this camera displayed
Enter the next camera number in the sequence
Wait the desire amount of time you want this camera displayed
Repeat procedure until all cameras have been entered in the
sequence
Press to cancel or to exit and save the sequence and exit
KTD-405 keypad (Standard Operation)
Controlling a recording device:
Requires a KTD-93 interface (RS-422 to RS-232)
Key
Function DSR/VCR
Starts recording
Stops record or playback
Starts playback
Pauses playback
Fast Forward
Fast Reverse (rewind)
Frame advance
Depends on device (DSR/VCR)
Frame reverse
Depends on device (DSR/VCR)
Joystick
↻ Twist right = variable rate forward
↺ Twist left = variable rate reverse
Zone Mode
KTD-405 keypad (Standard Operation)
Programming a Calibur™ multiplexer:
Zone Mode
Requires RS-485 connection
seq9,5,1,
Enter programming via the Remote Programming code
Select 1 for switcher/multiplexer
Select 2 for Calibur
Enter the Calibur RS-485 address
Press
(ENTER)
Enter the Calibur password for the device
KTD-405 keypad (Standard Operation)
Programming a Calibur™ multiplexer:
Zone Mode
Navigate the Calibur multiplexer menus with these keys:
Key
Function
Joystick moves left, right, up, down in menus
Makes selections
Backspaces out of selections or exits programming from the main menu
Move up in menus
Move down in menus
Move right in menus
Move left in menus
Same as
esc
Same as
KTD-405 keypad (Standard Operation)
Keys with special functions:
These keys have some special applications:
Key
Function
Programmable two ways:
view
Use with number keys to display mult-image views (if supported)
Used to sequence through multi-display image views (if supported)
aux 1
OPEN or Preset 58
aux 2
CLOSE or Preset 59
aux 3
STOP or Preset 60
aux 4
TALK or Preset 61
tour
Used for activating tours or Auto-Pan mode
find
Used to send the selected camera to a preset (if camera is capable)
esc
Clears numerical menu entries (future function clears alarms)
auto
focus
dsr/vcr
Places selected CyberDome in auto-focus
Addresses remote recording device
KTD-405 keypad (Standard Operation)
Keys with special functions:
These keys have not been implemented yet:
Key
alarm
1st
Function
Alarm key
1st (First) key
PYTANIA