Introduction to HUWA-SAN

Download Report

Transcript Introduction to HUWA-SAN

Introduction to HUWA-SAN
Ecological Disinfection
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
1
Opening







What is HUWA-SAN?
Difference between H2O2 and HUWA-SAN
Test results
Applications – Fields of application
Comparison Huwa-San - other disinfectants
Advantages of HUWA-SAN
Measuring and monitoring instruments
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
2
Huwa-San
 1985: Development by Dr. Heinz Hungerbach
(Germany)
 1990: Agreement Roam Chemie/Hungerbach Inc.
 Roam Chemie marketing/sales in Belgium
 1998: † Dr. Heinz Hungerbach (77)
 2001: Roam Chemie bought formula/process
 Roam Chemie production/development/
marketing/sales worldwide
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
3
What is Huwa-San?
Disinfectant based on
 Stabilised and activated hydrogen peroxide
(H2O2)
 Colloidal silver as stabiliser and activator
(Ag)
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
4
Difference between H2O2 and HUWA-SAN
Hydrogen peroxide
Decomposes slowly, spontaneously in water and oxygen
H2O2
IP
H2O + O2
water
oxygen
Not stable in closed, clean packaging!
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
5
Summary
Hydrogen peroxide
 Not stable:
slow, spontaneous
decomposition in closed
packaging
 Almost complete
decomposition in contact
with pollution
 Moderate disinfection
Huwa-San
 Stable in closed packaging
(2 – 3 years)
 Depot-storage effect:
non-reacted hydrogen
peroxide remains
stabilised
 Excellent disinfection
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
6
Applications
Surface disinfection
 First clean and rinse with water (if necessary)
 Concentration:
 Method:
 Contact period
1-2% (TR-50)
sprinkle
minimum 15 min.
 Food:
 Non-food:
let it dry or rinse if still wet
let it dry, do not rinse
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
7
Applications
Material disinfection
 First clean and rinse with water (if necessary)
 Concentration:
 Method:
 Contact period
0,5-1% (TR-50)
submerge
minimum 15 min.
 Food/non-food:
let it dry, do not rinse
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
8
Applications
Pipe system disinfection
Pre-cleaned
 Concentration:
 Method:
 Contact period
250-500 ppm (TR-50)
dosage
minimum 1 hour
 Food:
 Non-food:
empty, rinse
empty, do not rinse
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
9
Applications
Pipe system cleaning and disinfection
Not precleaned
 Concentration:
 Method:
 Contact period
0,1-0,3% (TR-50)
dosage
minimum 1 hour
 Food/non-food:
empty, rinse
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
10
Applications
Storage tank disinfection
Method 1: fill tank with Huwa-San solution
 First clean and rinse with water (if necessary)
 Concentration:
 Contact period
250-500 ppm (TR-50)
minimum 1 hour
 Food:
 Non-food:
empty, let it dry or rinse if still wet
empty, let it dry, do not rinse
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
11
Applications
Storage tank disinfection
Method 2: sprinkle tank with solution
 First clean and rinse with water (if necessary)
 Concentration:
 Contact period
1% (TR-50)
min. 15 min.
 Food:
 Non-food:
let it dry or rinse if still wet
let it dry, do not rinse
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
12
Applications
Process water
Bottle rinsing (standdisinfection)
 Concentration:
 Method:
 Contact period
60-200 ppm (TR-50)
rinsing
minimum 1 min.
 Food/non-food:
let it drip out, do not rinse
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
13
Applications
Drinking water
 Concentration:
 Method:
 Contact period
5-20 ppm (TR-50)
dosage
continuous
 Maximum 20 ppm
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
14
Fields of application
Huwa-San TR-5
Huwa-San TR-50







food processing
Dairy industry
Beverage industry & breweries
Drinking water treatment
Medical sector – nursing institutes
Agriculture
Pharmaceutical industry –
cosmetics
 Stock-breeding/meat processing
 Airconditioning – cooling towers




Restaurants – hotels –schools
Swimming pools (surface)
SPA’s – saunas (surface)
Household – leasure accomodation
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
15
Comparison
Chlorine
Aldehydes
Quat. Amm.
Huwa-San
irritating
no foam
not
irritating
no foam
not
(slightly) irritating
foam
yes
odourless
no foam
not
yes
yes
yes
food:
dry/rinse
non-food: dry/no rinsing
chlorine gas(1) chloroorg chl comp(2) methylether(3)
(1): toxic
(3): toxic
(2): irritating
no
no
no sign. risks
no sign. risks
not
biodegradable
not
biodegradable
biodegradable
Properties
Odour
Foam
Greasy
Application
Rinsing after use
Risks for user
Byproducts
Hazard
Biodegradability
not
biodegradable
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
16
Effectiveness
 Bacteria
(grampos & gramneg)
Pseudomonas aeruginosa, Escherichia coli, Staphylococcus aereus, Enterococcus faecium,
Mycobacterium smegmatis
 Spores
Bacillus subtilus, Bacillus cereus, Clostridium sporogenes
 Fungi
Absidia corymbifera, Cladosporium cladosporioides, Candica albicans, Penicillium verrucosum
Huwa-San acts as an algicide and amoebicide!
Huwa-San is extremely effective in removing biofilm and against legionella!
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
17
Advantages of HUWA-SAN






Highly effective even in low concentrations.
Effective in a wide range of temperatures up
to the boiling point.
Odourless
Produces no foam
Biodegradable (decomposes into water and oxygen)
Non-toxic.
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
18
Measuring & monitoring
 Measuring instruments
Spectrophotometer
Test strips
photometric measurement
range: 0 - 150 ppm
accuracy: 1 ppm
range: 0 -200 ppm
accuracy: 10 ppm (indicative)
 Measuring and monitoring instrument
Automatic dosage and measuring instrument to monitor the Huwa-San
concentration (process and drinking water)
photometric measurement
range: 0 - 100 ppm
accuracy: 1 ppm
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
19
Measuring & monitoring
Measuring instruments
 Spectrophotometer
photometric measurement
range: 0 - 150 ppm
accuracy: 1 ppm
 Test strips
range: 0 -200 ppm
accuracy: 10 ppm (indicative)
Kunzmann - Texcon Marketing
21/07/2015
CH-4142 Münchenstein
20