J-Field Feasibility Study
Download
Report
Transcript J-Field Feasibility Study
Shelter In Place
Measures of Protection
August 2005
Presented by
Weston Solutions, Inc.
Proprietary Information
Copyright © 2005, Weston Solutions, Inc.
05M-0044.1
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Outline of Presentation
05M-0181.2
Why Discuss Shelter in Place
Review Types of Shelter In Place Systems
How to Evaluate Facilities for SIP Protection
Review of SIP Sealing Measures
Prior Experience
Discussion
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Two Potential Responses to
Contaminated Airborne Incidents
Evacuate - Flee
Take Refuge – SIP
-
05M-0181.3
Sustainability to Continue Operations
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Why Shelter In Place
Types of Threats
05M-0181.4
Acts of Terrorism
-
Dirty Bomb – Radioactive Dust
-
Chemical Weapons – Nerve or Blister
-
Biological Spores – Anthrax
Toxic Industrial Chemicals (TIC’s)
-
Chlorine
-
Phosgene
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Measure of Toxic Chemical Threat
Immediate Danger to Life and Health
IDLH is a condition that poses a threat of
exposure from airborne contaminants when that
exposure is likely to cause death or have a
delayed permanent adverse health effect.
05M-0181.5
AGENT
TYPE
IDLH
GA/GB
Nerve
0.2 mg/m3
GD
Nerve
0.06 mg/m3
VX
Nerve
0.02 mg/m3
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Shelter-In-Place
Measures of Protection
05M-0181.6
Normal Sheltering
Expedient Sheltering
Enhanced Sheltering
Enhanced Plus Filtration
Collective Protection Overpressure
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Normal Sheltering
05M-0181.7
Taking Refuge in an existing unmodified
building to prevent and/or reduce exposure to
toxic chemicals.
Protection involves closing doors, windows,
and deactivating HVAC.
Normal Sheltering helps protect individuals
from exposure when emergency action is
precautionary, plume passage is short, and
concentrations are low.
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Expedient Sheltering
05M-0181.8
Taking Refuge in an existing unmodified building
to prevent and/or reduce exposure to toxic
chemicals.
Protection involves closing doors, windows, and
deactivating HVAC.
Measures includes providing plastic sheeting &
duct tape to windows, doors, and air vents.
Expedient Sheltering provides adequate
protection when airborne chemical release is
low to moderate and exposure time is less than
2 to 3 hours.
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Enhanced Sheltering
05M-0181.9
Taking Refuge in an existing building that has
previously been retrofit to reduce air infiltration.
Retrofit measures include permanent sealing measure
modifications to buildings protective perimeter
reducing outside air infiltration changes per hour.
Protection measures incorporate architectural sealing
measures with automated mechanical isolation
dampers and controls to deactivate existing HVAC.
Enhanced Sheltering provides adequate protection
when airborne chemical release is low to moderate
and exposure time is less than 2 to 3 hours.
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Enhanced Plus Filtration Sheltering
05M-0181.10
Taking Refuge in an existing building that has be
previously retrofit to reduce air infiltration and provide
filtered outside air through existing HVAC systems
creating a slight overpressure relative to atmosphere.
Protection measures incorporate sealing measures,
and controls to filter (Particulate & Chemical) outside
air intake through filtration system providing toxic free
air to existing HVAC systems.
Enhanced Plus Filtration Sheltering provides adequate
protection when airborne chemical release is moderate
to high and exposure is less than filter life.
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Collective Protection Overpressure
Sheltering
05M-0181.11
Taking Refuge in an existing building that has be previously
retrofit to reduce air infiltration and provide filtered outside air
through dedicated Filtrated HVAC systems.
Protection measures incorporate architectural sealing
measures, mechanical isolation dampers, electrical and
controls to deactivate existing HVAC and
Provide dedicated Filtered HVAC air to maintain 0.2” (50 pa)
positive pressure within the building envelope relative to the
atmosphere.
Collective Protection Overpressure Sheltering provides
adequate protection when airborne chemical release is
moderate to high and exposure time is less than filter life or
available backup utility.
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Engineering Assessment
of Facilities
05M-0044.12
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Engineering Assessment
for Anticipated Threats
05M-0181.13
Define Purpose and Use of Building
Number and Types of Occupants
Length of Time for Protection
Existing HVAC Systems
Facility Construction Type and Leakage Rates
Life Safety Systems
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Evaluate the Selected Protective Perimeter
05M-0181.14
Buildings have three
methods of air exchange
-
Forced Ventilation
-
Natural Ventilation
-
Infiltration Ventilation
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Forced Ventilation
05M-0181.15
Mechanical conditioning of outside air that is
pumped into and out of the buildings interior.
HVAC Systems
Controlled Air Source
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Natural Ventilation
05M-0181.16
Exchange of building air with outside air using
intentional openings of a building
Doors and Windows
Controlled Air Source
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Infiltration Ventilation
05M-0181.17
Exchange of building air with outside air using
unintentional openings of a building
Cracks, joints, seams, pores, and voids
Effected by wind speed and temperature
difference
Uncontrolled Air Source
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
ASTM E779-99
Determine Air Leakage Rate By Fan Pressurization
05M-0181.18
Blower Door Testing
Measures
-
Equivalent leakage
Area (ELA)
-
Uncontrolled Air
Changes per Hour
(ACH)
or total Air
Infiltration
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
From Blower Door Test Data
Evaluate Corrective Measures
05M-0181.20
Select Type of Shelter In Place Measures
Architectural Changes
Mechanical Changes
Electrical Changes
Control Changes
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
05M-0181.21
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Architectural Measures
Apply liquid foam that solidifies to wall and
ceiling interfaces, cracks, voids, and
penetrations through perimeter walls.
Framing and installing GWB ceilings
Weatherize perimeter doors
Weather-stripping
- Door Bottoms & Thresholds
-
05M-0181.22
Install new windows and doors
Provide weatherized glass door fronts
separating zones
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
05M-0181.23
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
05M-0181.24
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Architectural
05M-0181.25
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Mechanical Measures
05M-0181.26
Install low leakage dampers at air handler
inlets, unit ventilators, supply ductwork, and
exhaust fans.
Provide Filtration Unit System
-
Filter & Housing assembly
-
Air Cooled Condensing Units
-
DX Coil – heat exchanger
-
Gas Fired Burner
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Mechanical
Mechanical Isolation Dampers with Actuator
05M-0181.27
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
05M-0181.28
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
05M-0181.29
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
05M-0181.30
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Electrical Measures
05M-0181.31
Dedicated Power Distribution Switchgear
Emergency Backup systems
-
Auxiliary Generator
-
Automatic Transfer Switch
-
Emergency Lighting
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
05M-0181.32
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
05M-0181.33
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Control Measures
05M-0181.34
Automate and Monitor existing HVAC.
Monitor Perimeter Door Position.
Stroke mechanical isolation dampers.
Engage filtration system.
Engage Emergency Backup system.
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
05M-0181.35
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
05M-0181.36
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Weston Experience
05M-0044.37
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Current Client List
05M-0181.38
US Army Corps of Engineers
-
Clarks Moore Middle & Waco Elementary School –
Collective Protection Over Pressurization
-
Richmond Child Care Center – Enhanced SIP
-
Telford Terrace – Enhanced SIP
-
Willis Manor – Enhanced SIP
-
McCready Manor – Enhanced SIP
-
Madison County Senior Citizens Center –
Enhanced SIP
-
Pattie A. Clay Hospital – Enhanced SIP + Filtration
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Current Client List
US Postal Service (SIP Assessment)
- Anniston
- Blue
Mountain Post Office
- Oxford
- Fort
Post Office
Post Office
McCullen Post Office
- Bynum
Post Office
- Middlesex
05M-0181.39
Essex Post Office
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Current Client List
US Army Corps of Engineers
- Confidential
05M-0181.40
Command Center
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Facilities at Risk
All Government Facilities
05M-0181.41
Federal/State/Local
-
Command & Control Centers
-
Air Traffic Control Towers
-
Emergency Response Facilities
-
Postal Facilities
-
Military Bases
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Facilities at Risk
Public Gathering Facilities at higher risks
of occupancy (can not evacuate)
- Public
- Child
and Private Schools
Care Centers
- Homes
for the Elderly
- Hospitals
05M-0181.42
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
Thank You for Your
Time and Participation
05M-0044.43
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.
For More Information, Contact:
Mr. Chris Young
Client Service Manager
Weston Solutions, Inc.
1400 Weston Way
West, Chester, PA 19380
610.701.3411
Or
Mr. Hal Blakemore
Project Manager
Weston Solutions, Inc.
1400 Weston Way
West Chester, PA 19380
610.701.3403
05M-0044.44
Information contained herein is the property of and is proprietary to Weston Solutions, Inc. and shall not
be reproduced, disclosed, or used without the prior written permission of Weston Solutions, Inc.