V11P V11PT Product Presentation_CP1

Download Report

Transcript V11P V11PT Product Presentation_CP1

Valor 1000 single-dual display models
CP1-0 / September, 2009
Valor 1000 Series - UPDATE
NOW with dual-display models: V11P-T
1
Internal usage only
Valor 1000 Series - Mission
Compete in low cost dry food service/
portioning segment with simple, portable
and low cost precision scale
2
Internal usage only
Valor 1000 Series - Concept
Address New Markets…
 Low cost Precision general weighing
 Low cost compact food portioning
With New Product….
 Sleek profile, large backlit display, internal battery
 Removable stainless steel pan, smooth housing
 Bench or tabletop friendly footprint
Deliver Ohaus Value
 Good performance, good quality, low cost
 Check and accumulate application modes
 Competitive pricing vs. others
3
Internal usage only
Valor 1000 Series - USP’s
Ergonomic design
 Small footprint, mid height, large stainless pan
 Bright easy-to-read backlit LCD (dual display models
now available), with audible alarm
Solid performance
 Resolutions up to 7,500d
 Level bubble and feet maximize accuracy
 Digital external span calibration
Friendly operation
 Easy to clean, Easy transport size
 Long life Standard Battery or AC power with auto shut off light
 Simple Check weigh, and accumulate functions
4
Internal usage only
Valor 1000 Series - Std Features
Standard Features
ABS plastic housing with SS pan
Weighing units: kg, lb, g, oz
Check weigh and Accumulate modes
Level bubble and adjustable feet
Four raised tactile mechanical buttons
Internal rechargeable ~80 hour lead acid battery
7-segment 6 digit backlit LCD (front / front-rear)
Stability indication, Auto zero tracking
Power saving auto shut off backlight
Subtractive Tare up to capacity
Power toggle switch
Low battery, over under accept indicators
AC power adapter
5
Internal usage only
Valor 1000 Series – Models/Apps
V11P3
V11P6
V11P15
V11P30
V11P3T
V11P6T
V11P15T
V11P30T
3kg x 0.5g
6kg x 1g
15kg x 2g
30kg x 5g
Applications
General weigh
Dry Portion
Check weigh
Production line
Ingredient mixing
6
Internal usage only
Valor 1000 Series - Competition
Capacities
Resolution
Accessories
Housing
Display
Power
Modes
Approvals
Other
List Price Range
Valor 1000
CAS SW
A&D SK
Gram DV
3-30kg
7,500d (non apvd)
2-20kg
2,000d apvd
1-30kg
5000d (2000d apvd)
1-30kg
11,000d (non apvd)
SS Pan
SS Pan
SS Pan
SS Pan
ABS plastic, with level ABS Plastic with level ABS Plastic with level
bubble and feet
bubble and feet
bubble and feet
Blue Backlit LCD
LCD
LCD
ABS plastic,
adjustable feet
Backlit LCD
(front / front-rear)
AC or Standard Lead
AC or battery 1000
6 'D' size batteries (not AC or Standard Lead
acid Battery ~80 hours hours for alkaline (not
included) or AC
acid Battery ~200
included) ~500 hours
Adapter (optional
hours
for manganese (not
$22.00)
included)
Weigh in lb,kg,oz,g
Weigh in lb,kg,oz,g
Weigh in g,kg,lb, lb:oz
Weigh in g only
Acc. Mode, Check
weigh mode
None
None
~$150-200
NTEP
NTEP
Second display option Second Display option
$250
7
~$270
None
None
$250
Internal usage only
Valor 1000 Series – OH Positioning
List Range
Cap x Read
Valor 1000
Valor 2000
Valor 3000
Valor 5000
FD
$150-$200
$220-$295
$200-$395
$350
$395
3gk x 0.5g
3kg x 0.5g
200g x 0.01g
3kg x 0.5g
3kg x 0.5g
6kg x 1g
6kg x 1g
2000g x 0.1g
6kg x 1g
6kg x 1g
15kg x 2g
15kg x 2g
15kg x 2g
15kg x 2g
3kg x 0.1g
3kg x 0.1g
6kg x 0.2g
6kg x 0.2g
15kgx 0.5g
15kgx 0.5g
30kg x 5g
30kg x 1g
Housing
IP Rating
Max d
Units
Display
Pan size
Power
Type Approvals
Certifications
Modes
ABS Plastic
ABS Plastic
SS
ABS Plastic
SS
None
All IP65
Some IP65
Some IP65
Some IP65
7,500d
7,500d
20,000d
30,000d
30,000d
kg,lb,g,oz
Backlit LCD
(front / front-rear)
kg,lb,g,oz
kg,lb,g,oz, lb:oz, dec
oz, fr oz
kg,lb,g,oz, lb:oz, dec
oz, fr oz
kg,lb,g,oz, lb:oz, dec
oz, fr oz
LED
Backlit LCD
Backlit LCD
Backlit LCD
AC and IR lead acid
AC and IR lead acid
AC or 3 C battery
AC and IR lead acid
AC and IR lead acid
None
NTEP/OIML
NTEP/OIML
NTEP/OIML
NTEP/OIML
None
NSF, USDA
NSF, USDA
NSF, USDA
NSF, USDA
Weigh, Check,
Accumulate
weigh
Weigh, % S-gravity, Fl
oz
Weigh, Check with
LED
Weigh, Check with
LED
8
Internal usage only
Valor 1000 Series– Contents
Valor Box 1000 includes:
1x Scale
1x SS platform
1x AC adapter
1x 5 language operator manual
9
Internal usage only
Valor 1000 Series– Model Numbers
V11PXT
V:
Family ID (V for Valor)
1:
Series level (1000 series)
1:
Version 1= First version of Valor 1000
P:
Housing Designator (X = Stainless steel, P= Plastic)
X:
kg Capacity Digit
T:
“T”wo display version
10
Internal usage only
Valor 1000 Series– Keypad
ZERO (enter)
Zero’s scale display not
subtractive of capacity
(Accept when used in menu,
clears accumulated value
when in accumulate)
SELECT & M+
Change weighing units
Kilograms (kg)
Pounds (lb)
Ounce (oz)
Gram (g)
TARE (down arrow)
Subtracts value on pan from
capacity
(decrement size when used
in menu)
SELECT (left arrow)
Used in conjunction with M+
to change weighing unit,
used in conjunction with zero
to enter check weigh mode
(decrements in menu)
M+ (up arrow)
Add weight on pan for
accumulate mode, when pan
empty recall current stored
weight
(increments in menu)
11
Internal usage only
Valor 1000 Series– Setup
Basics
Attach mains power
Charge battery 8-12 hours before
use
Set on firm level surface, adjust feet
for leveling
Calibrate scale before operating
12
Internal usage only
Valor 1000 Series– Setup
Changing Units
Press M+ key and SELECT key to
change unit of measure (g,kg,lb,oz)
Backlight
Press and hold ZERO button until
[b9---x] is displayed, where x=
0 = backlight is turned off
1 = backlight is on during weighing
2 = backlight is always on
Press TARE to change the setting. Press
ZERO to confirm the setting and return to
weighing.
13
Internal usage only
Valor 1000 Series– Setup
Calibration………..Important
Default settings for divisions and decimal point should always
be selected during calibration.
Changes not recommended.
Scale will not calibrate if divisions or decimal point is changed.
To restart, turn scale off and begin calibration again.
14
Internal usage only
Valor 1000 Series– Setup
Calibration
Press and hold ZERO and SELECT during
power on "SET--- " will be displayed. Short
press the SELECT key until "SET-F1" is
shown
Short press ZERO key to accept F1 and
display "A____x” (x=divisions in grams).
Short press ZERO key to accept the default
division setting.
Short press ZERO key to accept and display
"b____x” (x=decimal point). Short press
ZERO key to accept decimal and display “C
xxxxx”.
15
Internal usage only
Valor 1000 Series– Setup
Calibration
Short press ZERO key to accept the default
span calibration weight setting (short press
M+ or TARE to increment or decrement)
Short press ZERO to accept calibration
weight and display "dxxxx”. Short press
ZERO key to accept the default setting
Short press ZERO and display will show
"Load 0". Make sure pan is empty then short
press ZERO key. Display will show "CAL 0"
briefly, then "Load F”
Short press ZERO to display "Fxxxxx”. Put
displayed weight on the scale, and short
press ZERO to accept.
16
Internal usage only
Valor 1000 Series– Operation
Basic Weigh
Turn on scale by flipping toggle switch
under right side of scale
Segment check and serial number will be
displayed
Keep pan clear and wait for stability and
center of zero indicator.
Place container on scale and press Tare
key.
Place object in container – net weight will
be displayed, stability indicator will appear.
17
Internal usage only
Valor 1000 Series– Operation
Check Weigh
Use this mode to quickly compare samples
to a specified tolerance range.
 Press ZERO key to set the display to
zero.
 Place a sample on the pan and read the
weight and under / accept / over status
on display.
 Scale will beep when weight is in
tolerance or outside tolerance (user
selectable setting)
18
Internal usage only
Valor 1000 Series– Operation
Check Weigh (setup)
Over and Under Limits

Press and hold ZERO and press SELECT until
[SET---] is displayed.


Press SELECT to display [SET-F0]


Press , ,  to edit the upper limit.

Press , ,  to edit the lower limit.
Press SELECT to view the upper limit
[000000].
Press ENTER to confirm the setting and
display the lower limit [000000].
 Press ENTER to confirm the lower setting
and display the alarm setting [run__x],
19
Internal usage only
Valor 1000 Series– Operation
Check Weigh (setup con’t)







X=0 Alarm and under / accept / over indicators
are off.
X= 1 Under / accept / over indicators are
displayed, alarm beeps when weight is outside
accept range.
X= 2 Under / accept / over indicators are
displayed, alarm beeps when weight is within
accept range.
X=3 Under / accept / over indicators are
displayed, alarm is off..
Press SELECT to change the alarm setting.
Press ENTER to confirm setting and display
[End]
Press and hold ZERO key and press SELECT
to return to weighing.
20
Internal usage only
Valor 1000 Series– Operation
Σ
Accumulate
Press ZERO to set the display to zero.
Place the sample on the pan.
Press M+ to store the weight of the
Accumulate
sample. Storage is confirmed by the
display [n x], where n is the sample
number.
Remove the sample and place the next
sample on the pan and press M+.
21
Internal usage only
Valor 1000 Series– Operation
Σ
Accumulate (con’t)
Repeat this process until all samples have
Accumulate
been weighed.
Review the accumulation data by pressing
M+ when the display is at zero.
The display first shows the number of
samples [n
x]
Press M+ to view the maximum sample
weight [Hxxxxx].
Press M+ to view the minimum sample
weight [Lxxxxx].
Press M+ to view the total sample weight
[xxxxx].
22
Internal usage only
Valor 1000 Series– Value Prop
Customer Needs:

Inexpensive,
compact design

Portable with good
performance

Easy to keep clean
and store after day
of use
Ohaus Solution:
Customer Value:

Efficient, full ABS
plastic design

Best of both worlds, low
cost, yet Ohaus quality

Lightweight, battery
powered- Up to
7,5000d resolution

Easy to transport, no
power cord needed,
precision accuracy

Smooth shapes, no
gaps, or ridges,
removable pan,
portable size

Low maintenance
Trouble free operation
USP
USP
USP
23