Fresenius Peritoneal Dialysis Connections

Download Report

Transcript Fresenius Peritoneal Dialysis Connections

Fresenius Medical Care Peritoneal Dialysis
Connections
Baxter to Safe-Lock Connection
Connections using Fresenius Medical
Care products
This inservice is not intended to replace the advice
or training from your physician. Refer to the
Instructions For Use (IFU) for detailed device
description, instructions, contraindications,
warnings, and precautions.
Fresenius Medical Care, DEL-CLAMP, Stay●Safe,
Safe-Lock, DELFLEX and FREEDOM are
trademarks of Fresenius Medical Care Holdings
Inc. or its affiliated companies. All other
trademarks are the property of their respective
owners.
Fresenius Products
Baxter is a trademark of Baxter International Inc. or its
affiliates.
Instructions on how to use Baxter products were reproduced
from the manufacturer’s literature and were current at the
time of print. Instructions are included for the patient's
convenience but Fresenius Medical Care North America
does not specifically endorse the use of these products or
assume any liability related to their use. Should there be
any differences between the instructions listed in this
manual and the instructions for use provided with the
medical devices referenced, the instructions provided with
the medical device should be taken as accurate."
Connections using Fresenius Medical
Care products
Note: for clarity the model is shown not
wearing personal protective equipment
(PPE). Follow your facility’s policies and
procedures for use of personal protective
equipment.
It is vital to maintain sterility of the
connectors during connection procedures.
Safe-Lock Systems
Please note Safe-Lock systems include:
1.
2.
3.
4.
5.
Delflex Premier Plus exchange set
Freedom Y-set with snap disconnect
All Freedom cycler tubing sets
Newton cycler set with safe lock connectors
8 Lead Safe-Lock Manifold set
Safe-Lock Connections
Catheter adapter on catheter
4 inch convertible extension set
Extension set with roller clamp
Premier transfer set
Patient catheter
or extension
tubing segment with
Del-clamp
The patient’s Safe-Lock connector or extension set will look like one
of the above. These are photos of the patient catheter or catheter
extension set with a tubing segment secured with a DEL-CLAMP
clamp attached.
Baxter patient to Safe-Lock system
A Convertible Extension Set or Premier Transfer Set with Luer
Patient Connector will allow the patient with a Baxter PD system
to use Fresenius Safe-Lock supplies while in the hospital.
Convertible Extension
Premier Transfer
Set with Luer
Patient Connector
Patient using Baxter
Safe-Lock Supplies
Baxter patient to Safe-Lock system
1. Gather supplies
4 inch Convertible
Extension (P/N # 05040026)
or
8 inch Premier Transfer Set
with Luer Patient Connector
(P/N # 050-30034)
Safe-Lock solution set
and related supplies for
transfer set connection
and exchange procedure.
Baxter patient to Safe-Lock system
1. Remove blue sterility cap at small
end of Fresenius adapter.
2. Remove the mini-cap from the
Baxter patient extension set.
1
3
2
3. Attach the Fresenius
set to the end of the
Baxter extension set.
Proceed with exchange
as per procedure.
3
DISCHARGE INSTRUCTIONS
FOR ALL CONNECTIONS
• The patient should return to his/her
home or clinic with the additional
extension in place. This practice will
allow the patient to return home and
resume dialysis without interruption.
• Instruct the patient to remove any
adaptors added to their extension set at
the beginning of the next exchange or
as directed by the PD clinic nurse.
Choose the type of catheter or transfer set and the type of system utilized.
Look down the column and across the row to the adapter needed. Click
on the icon in the box to take you to the procedure
Select the catheter or transfer set used by the patient.
Select the
System
the
Hospital
Uses
Catheter
or
With LuerLock Adapter
Titanium
With SafeLock Adapter
Transfer Set
or
With Baxter
Transfer Set
Hospital
Uses Baxter
Supplies
Add
Baxter Transfer
Set
5C4484
Hospital
Uses
Fresenius
(FMC) SafeLock
Supplies
Add Safe-Lock
Transfer Set with
Luer Lock Adapter
050-30034
No Change
Needed OR
Add a FMC SafeLock Transfer Set
with a Safe-Lock
Adapter
Add Convertible
Extension
050-40026
Hospital
Uses FMC
Stay-Safe
Supplies
Add
Stay● Safe
Extension Set
with Luer lock
Patient Connector
050-95004
Add
Stay● Safe
Extension Set
with Safe lock
Patient Connector
050-95001
Add Stay● Safe
Luer Lock Adapter
050-95003 and a
Baxter Transfer
Set 5C4484
Add FMC
Universal
Connector
050-30026 or
pre-filled
050-30031
No Change
Needed
or
With
Fresenius
Safe-Lock
transfer Set
With
Fresenius
Stay-Safe
Transfer Set
Add FMC
Convertible
Adapter 05040393 and Baxter
5C4484
Add
Stay●Safe Luer
Lock Adapter 4”
050-95003
No Change
Needed
Add Stay● Safe
Extension set
with Safe-Lock
Patient connector
050-95001
Add
4” Stay●Safe
Safe-Lock
Adapter
050-95006
No Change
Needed
Please contact your Fresenius
Clinical Sales Representative at
1-800-662-1237 if you have
questions regarding the use of a
Fresenius PD system or adapter.
CD Available through Customer Service