Transcript Slide 1
Air conditioning – Refreshes your life Applied Systems Single Screw STEPLESS CAPACITY CONTROL Chillers Air conditioning – Refreshes your life Single Screw Chillers STEPLESS CAPACITY CONTROL CO N T E N T What is new ? Stepless Single Screw Compressor One control platform, pCO² digital controller PE - Condenser Coils Max. Protection & Easy Installation Nomenclature New chiller ranges : EWAP 110 ~ 540 MBYNN EWAD 120 ~ 340 MBYNN ERAP 110 ~ 170 MBYNN EWWD 120 ~ 540 MBYNN EWLD 120 ~ 540 MBYNN (EUWA - MZY) (EUWA - KBXY) (ER - MZY) (EUW - MAXY) (EUWL - MXY) Air conditioning – Refreshes your life Stepless Single Screw Compressor History F-type G-type G-type stepless time 2000 Slide valve (New design) 2003 Gate rotor shaft (Strong type) 2005 Implications Increased COP 5% to 10% New high efficiency motor New shape of the screw Air conditioning – Refreshes your life Stepless Single Screw Compressor History F-type G-type G-type stepless time 2000 2003 2005 Robustness, reliability = Robustness, reliability Performance = Performance Dimensions = Dimensions Limited control (stepped) ≠Extended control (stepless) The stepless compressor is a DAIKIN development ! Designed, tested and manufactured in Daikin’s own laboratories. Air conditioning – Refreshes your life Stepless Single Screw Compressor Launch of STEPLESS capacity control (Sales launch: August 2005) Better control of the chiller at partial load WHAT YOU WANT IS WHAT YOU GET G-type stepless More accurate control of the temperature OUTLET CONTROL (+/- 0,5°C) If water quantity chiller + system ≥ minimum water quantity No buffertank required Saves the environment’s resources … and nevertheless your own resources DAIKIN compressor = the compressor that you can count on Designed, tested and manufactured in Daikin’s own laboratories. Air conditioning – Refreshes your life Stepless Single Screw Compressor STEPLESS capacity regulation The compressor has built-in capacity control by 15 – 100% by stepless slide valve mechanism, and adjustable volumetric ratio Chiller Load Chiller Load 100% 100% 30% Starting position 12% Demand Single Circuit 15% 12% Starting position Demand Double Circuit Designed, tested and manufactured in Daikin’s own laboratories. Air conditioning – Refreshes your life Stepless Single Screw Compressor STEPLESS capacity regulation How does it work ? Pilot Valve Loading and unloading via Pilot Valve: -Pilot valve is driven by rod mechanism -The rod mechanism is driven by shaded-pole motor Loading Unloading High pressure side Rod mechanism Air conditioning – Refreshes your life Stepless Single Screw Compressor STEPLESS capacity regulation How does it work ? Pilot Valve Balancing hole Bleedhole for pilot valve High pressure side Loading Unloading Rod mechanism Air conditioning – Refreshes your life Stepless Single Screw Compressor Sliding Vane Spring Gate rotor HP (High Pressure) @ 100% Position of PILOT VALVE is not changed! Load/unload mechanism HP HP dHP Low Pressure Small bleed Towards LPside (Indicated by the green circle) Pilot Valve Low Pressure HP dHP (ΔP = 2kg/cm²) HP = dHP Main screw Dynamic HP Bearing of the rotor HP (High Pressure) Rod mechanism driven by shaded-pole motor SLIDING VANE stays @ position 100% Air conditioning – Refreshes your life Stepless Single Screw Compressor Position of pilot vane moves to right side (towards 90%) @ 100% Position of PILOT VALVE moves right HP HP dHP Low Pressure Bigger bleed Towards LPside Low Pressure HP HP > dHP dHP Unloading from 100% to 90% SLIDING VANE moves to right decrease CC Air conditioning – Refreshes your life Stepless Single Screw Compressor @ 95% Position of PILOT VALVE moves right HP HP dHP Low Pressure Bigger bleed Towards LPside Low Pressure dHP HP > dHP HP SLIDING VANE moves to right decrease CC Air conditioning – Refreshes your life Stepless Single Screw Compressor @ 90% Position of PILOT VALVE is not changed! HP HP dHP Low Pressure Small bleed Towards LPside (Indicated by the green circle) (ΔP = 2kg/cm²) Low Pressure dHP HP HP = dHP SLIDING VANE stays @ position 90% Air conditioning – Refreshes your life Stepless Single Screw Compressor Small bleed HP LP dHP Position of PILOT VALVE Does not move Towards LPside HP = dHP Bigger bleed HP LP dHP Position of PILOT VALVE moves RIGHT Towards LPside NO bleed dHP Chiller Load 100% t0 = t1 15% Demand SLIDING VANE moves to right decreased CC Chiller Load 100% t0 t1 HP > dHP HP LP SLIDING VANE does not move no CC change 15% Demand SLIDING VANE moves to left increased CC Chiller Load Position of PILOT VALVE moves LEFT Towards LPside 100% t1 t0 HP < dHP 15% Demand Air conditioning – Refreshes your life One control platform, pCO² digital controller The pCO² gives you stronger control functions … • Ensures efficient & harmonious operation of unit • Efficient control of the chilled water temperature • Control operating range of unit • Manage safe operation of unit • Provide useful information to the user Schedule time groups (4) Floating set point according to ambient temp. Comprehensive control logic for independent free cooling Load shedding through capacity setback (night setback) Customized control by programmable input/outputs D.I.C.N. = Daikin Integrated Chiller Network Combine up to 4 Daikin chillers as if they were 1 unit STANDARD Air conditioning – Refreshes your life Better control enables you to use your air conditioning in many more ways … UNIT Remote Controller pCO² - Controller EKRUPC pCO-controller BMS (Building Management System) EKAC200A Gateway RS232/485/422 EKBMSMBA EKBMSBNA Air conditioning – Refreshes your life PE – Condenser Coils All our AIR HEAT EXCHANGER Have a high corrosion resistance that guarantees you a longer operational life and reliability. Polyacryl pre-coated Change from ‘Chromate Treated’ coils to ‘PE - coated’ coils: Similar resistance as chromate treated coils Applied successfully on VRV, Split, Sky-Air, Small Chillers Company’s quality and environmental policies A) Waffle louvre fins B) Cross fin coil with Hi-X tubes (Aluminum) Lubricant layer Hydrophilic layer Colouring & Corrosion proof Corrosion proof layer Air conditioning – Refreshes your life Max. Protection and Easy Installation To secure the safety of YOUR installation + EASY INSTALLATION Delivered as a kit Perforation diameter = 1mm Supplied standard with units with BPHE + Previous New: Factory Mounted Air conditioning – Refreshes your life NEW Nomenclature for Chillers ! Machine Type AAA EWA Air-Cooled Chiller C/O EWT Air Cooled Chiller C/O + H/R EWY Air-Cooled Chiller H/P EWC Air-Cooled Chiller Centr. Fan EWW Water-Cooled Chiller EWL Remote Condenser Chiller ERA C/O = Cooling Only H/P = Heat Pump H/R = Heat Recovery Air Cooled Condensing unit C/O Air conditioning – Refreshes your life NEW Nomenclature for Chillers ! AAA B Kind of Refrigerant D: R- 134a P: R- 407C Q: R- 410A Air conditioning – Refreshes your life NEW Nomenclature for Chillers ! AAA B CCC Capacity Class kW(!) Cooling From 1 to 950 kW Above 950 kW: Use multiples of C (Roman Character for 100) 1000 kW = C10 (100x10) 2500 kW = C25 (100x25) Air conditioning – Refreshes your life NEW Nomenclature for Chillers ! AAA B CCC DD Model Series First Character Letter A,B,… Major Modification Second Character Letter A,B,… Minor Modification Air conditioning – Refreshes your life NEW Nomenclature for Chillers ! AAA B CCC DD EE Power Supply W1 : 3N~ / 400V / 50Hz Y1 : 3~ 380-415V / 50Hz V1 : 1~ / 220-240V / 50Hz V3 : 1~ / 230V / 50Hz T1 : 3~ / 230V / 50Hz YN : 3~ / 400V / 50Hz Air conditioning – Refreshes your life NEW Nomenclature for Chillers ! AAA B CCC DD EE F Hydraulic Module N: NO Hydraulic components P: Pump B: Buffer Tank + pump M: Modular Air conditioning – Refreshes your life NEW Nomenclature for Chillers ! AAA B CCC DD EE F *** Option Code *** : 3 digits Air conditioning – Refreshes your life NEW Nomenclature for Chillers ! AAA B CCC DD EE F *** 12 characters = base model Fixed position for all characters Quick nominal capacity selection kW Air conditioning – Refreshes your life Single Screw Chillers STEPLESS CAPACITY CONTROL CO N T E N T What is new ? Stepless Single Screw Compressor One control platform, pCO² digital controller PE - Condenser Coils Max. Protection & Easy Installation Nomenclature New chiller ranges : EWAP 110 ~ 540 MBYNN EWAD 120 ~ 340 MBYNN ERAP 110 ~ 170 MBYNN EWWD 120 ~ 540 MBYNN EWLD 120 ~ 540 MBYNN (EUWA - MZY) (EUWA - KBXY) (ER - MZY) (EUW - MAXY) (EUWL - MXY) Air conditioning – Refreshes your life Single Screw Chillers STEPLESS CAPACITY CONTROL Water-Cooled Air-Cooled 40 50 60 70 80 90 100 EUWA EWAP EUWA EWAD ER ERAP EUW EWWD 110 140 160 200 280 120 140 340 160 400 * 120 150 170 240 300 180 460 * 200 540 * 340 KBXY MBYNN 110 150 170 MZY MBYNN 120 MAXY MBYNN 180 240 280 360 440 500 520 540 EUWL EWLD * Available on SPN-base MZY MBYNN MXY MBYNN 40 50 60 70 80 90 100 120 140 160 180 200 Air conditioning – Refreshes your life EWAP 110 ~ 540 MBYNN (EUWA - MZY) EWAP 110-160 MBYNN EWAP 200-340 MBYNN EWAP 400-540 MBYNN Product Features Useful Options Stepless Single Screw Compressor pCO² Digital Controller PE - condenser coils Brazed plate heat exchanger Built with high quality materials Modular, compact design, small service area Many safety devices Heat Recovery Inverter Fans High Pressure Fans Low Noise Operation Dual Pressure Relief Valve Suction Stop Valve Main Isolator Switch A-meter & V-meter Condenser Protection Grills Filter + Flow Switch + Water Sensor Air conditioning – Refreshes your life EWAP 110 ~ 540 MBYNN (EUWA - MZY) EWAP 110-160 MBYNN EWAP 200-340 MBYNN EWAP 400-540 MBYNN Product Features Many safety devices Flow Switch Filter + Flow Switch + Water Sensor Filter: protection PHE NOTE: supplied in a box, not mounted Water Sensor: ensures an accurate temp. indication NOTE: water sensor will be factory mounted Semi Full Standard Mounting * * NOTE: Only for EWAP 140-160 MBYNN Air conditioning – Refreshes your life EWAD 120 ~ 340 MBYNN (EUWA - KBXY) EWAD 120-170 MBYNN EWAD 240-340 MBYNN Product Features Useful Options Stepless Single Screw Compressor pCO² Digital Controller PE - condenser coils Shell & Tube heat exchanger Built with high quality materials Modular, compact design, small service area Many safety devices High Pressure Fans Low Noise Operation Suction Stop Valve Dual Pressure Relief Valve Main Isolator Switch A-meter & V-meter Condenser Protection Grills Flow Switch + Water Sensor Air conditioning – Refreshes your life EWAD 120 ~ 340 MBYNN (EUWA - KBXY) EWAD 120-170 MBYNN EWAD 240-340 MBYNN Product Features Many safety devices Flow Switch Flow Switch + Water Sensor Water Sensor: ensures an accurate temp. indication NOTE: water sensor will be pre-mounted Shell & Tube Full Standard Mounting Air conditioning – Refreshes your life EWWD 120 ~ 540 MBYNN (EUW – MAXY) EWLD 120 ~ 540 MBYNN (EUWL – MXY) EWWD 120-280 MBYNN EWWD 360-540 MBYNN Product Features Stepless Single Screw Compressor pCO² Digital Controller Brazed plate heat exchangers (evaporator) Useful Options Shell & Tube heat exchanger (condenser) Built with high quality materials Low Noise Operation Suction Stop Valve Modular, compact design, small service area Dual Pressure Relief Valve Many safety devices Main Isolator Switch A-meter & V-meter Condenser Protection Grills Filter + Flow Switch + Water Sensor Air conditioning – Refreshes your life EWWD 120 ~ 540 MBYNN (EUW – MAXY) EWLD 120 ~ 540 MBYNN (EUWL – MXY) EWWD 120-280 MBYNN EWWD 360-540 MBYNN Product Features Many safety devices Flow Switch Filter + Flow Switch + Water Sensor (one set per brazed plate heat exchanger) Filter: protection PHE NOTE: supplied in a box, not mounted Water Sensor: ensures an accurate temp. indication NOTE: water sensor will be pre-mounted Semi Not factory mounted Air conditioning – Refreshes your life ERAP 110 ~ 170 MBYNN (ER - MZY) Product Features Useful Options Stepless Single Screw Compressor pCO² Digital Controller PE - condenser coils Built with high quality materials Modular, compact design, small service area Many safety devices High Pressure Fans Inverter Fans Low Noise Operation Suction Stop Valve Dual Pressure Relief Valve Main Isolator Switch A-meter & V-meter Condenser Protection Grills Air conditioning – Refreshes your life Applied Systems Single Screw STEPLESS CAPACITY CONTROL Thank you for your attention! Chillers