PowerPoint 프레젠테이션

Download Report

Transcript PowerPoint 프레젠테이션

ORTEC®
ORTEC®
Safeguards/NDA
Specialized Instruments a
nd Software Solutions
ORTEC®
Safeguards and NDA Produc
ts
•
•
•
•
ISO-CART
ISOTOPIC
M-1-B32
Not exclusively for safeguards or nondestructive assay but also applicable t
o environmental analyses
ORTEC®
ORTEC - ANTECH Alliance
• Expands ORTEC’s range of nuclear s
afeguards and non destructive assay
products to include instruments such
as..
ORTEC®
- ANTECH Alliance
Safeguards and NDA Produc
ts
• U Hold-Up Measuring System HMS-3.
• Multiplicity Neutron Shift Register
AMSR-150.
– LANL design.
– authorized by IAEA.
– INCC and MIC software.
• DISTRIBUTION
AGREEMENT with ANTECH Corp.
ORTEC®
- ANTECH Alliance
ANTECH – Product Range
Transportable
Calorimeters
• Small sample Twin Cell microwatt
Calorimeter
NEW
• Large sample Pu Calorimeter
• Tritium Calorimeter
• Multiple Sample Preheating Units
www.antech-inc.com
ORTEC®
- ANTECH Alliance
ANTECH – Product Range
Neutron Measurements
• Time Correlation Analyser (TCA)
• Advanced Multiplicity Shift Register
(AMSR 150)
• Passive Neutron Packet Counter
• Passive Neutron Drum Monitor
• Combined Passive Neutron/Gamma
isotopic Drum Monitor
• SuperHENC Box and Crate Counter
• Active Well Coincidence Counter
• Fission-Fission Neutron Correlation
System
NEW
NEW
NEW
NEW
NEW
www.antech-inc.com
ORTEC®
- ANTECH Alliance
ANTECH – Product Range
Gamma-Ray Measurements
• Plutonium Isotopic System for Cans
• Plutonium Isotopic System for
Drums
• Segmented Gamma Scanner (SGS)
for Drums and Cans
• Universal Gamma Scanner forNEW
Cans
(TGS)
• Tomographic Gamma Scanner
(TGS) for Drums and Cans
NEW
www.antech-inc.com
ORTEC®
- ANTECH Alliance
ANTECH
Small Sample Calorimeter
• Twin Cell Compensating design
• Single or dual sample operation
• Single sample gives sub
microwatt resolution
• Unique high sensitivity multithermopile design.
• Transportable
• 50mm x100mm sample size
• Range 0-1W
www.antech-inc.com
ORTEC®
- ANTECH Alliance
Small Sample Calorimeter
Sample holders
Heaters
Voltmeter
+
-
Heat sink
Power Source
A
Outer Cylinder
B
Thermopile
ORTEC®
- ANTECH Alliance
ANTECH
Combined Neutron and Gamma Drum Monitor
• Suitable for low and intermediate level
waste.
• Optimised for use with ANTECH TCA
• Neutron coincidence and multiplicity
counting software.
• Neutron detector efficiency 20%.
• ORTEC 25% Coax detector with
DSPec electronics for Gamma
Isotopics.
• Isotopic analysis using LANL
PC/FRAM code.
www.antech-inc.com
ORTEC®
- ANTECH Alliance
Neutron Measurements
AMPTEK Preamplifiers
De Randomising Buffer
Drum
TCA
Detector Tubes
ORTEC®
- ANTECH Alliance
ANTECH
Active Well Coincidence Counter
• Active and Passive Neutron assay system
for measuring U and Up.
• Optimised for use with ANTECH AMSR
150.
• Updated LANL design incorporating derandomising buffer, internal Totals
counters.
• Improved mechanical design.
• High neutron detection efficiency -31%.
www.antech-inc.com
ORTEC®
- ANTECH Alliance
ANTECH
www.antech-inc.com
ORTEC®
- ANTECH Alliance
ANTECH
Universal Gamma Scanner for Cans
•
•
•
•
•
•
Combines TGS and PC/FRAM
isotopic analysis.
Comprehensive spatial gamma-ray
attenuation correction.
One measurement provides total
assay result.
Meets Safeguards, WIPP and QA
requirements of USA DOE.
Determines inventory of U, Pu and
other radio-nuclides.
Measures samples with high Am241 content.
www.antech-inc.com
ORTEC®
- ANTECH Alliance
ANTECH
Tomographic Gamma Scanner for Cans and Drums
• Comprehensive NDA waste assay
instrument incorporating TGS and
PC/FRAM isotopic analysis.
• Measures U, Pu and other radionuclides
• Meets all USA DOE Safeguards, WIPP
and QA requirements.
• Manual or automatic drum loading
• Comprehensive Attenuation and
Lump correction.
• Significantly more accurate than SGS
www.antech-inc.com
ORTEC®
- ANTECH Alliance
ANTECH
www.antech-inc.com
ORTEC®
- ANTECH Alliance
ANTECH
Waste measurement - TGS Advantages
• One instrument provides total Assay result combining TGS measurement of
U, Pu and other radio-nuclides with Pu isotopic ratio analysis using LANL
PC/FRAM code.
• Provides tomographic maps of absorbers and sources in heterogeneous
matrices.
• Determines the inventory of U, Pu, and other radio-nuclides in non
homogeneous samples including pyrochemical salt residues.
• Extends the range of the SGS technique to heterogeneous sample, such as
pyrochemical salt residues containing lumps of Plutonium.
• A single calibration constant can be employed for each radio-nuclide
determined due to the bias reduction inherent in the TGS technique.
• Measures samples with Am-241 content which cannot be measured by
neutron techniques.
• Accuracy and precision sufficient to meet safeguards, shipping and disposal
requirements.
• Suitable for measuring Pu oxide in cans.
• TGS technique indicates when a measurement is not successful, avoiding
large errors.
www.antech-inc.com
ORTEC®
- ANTECH Alliance
ANTECH
Waste measurement – TGS Features
• Gamma-ray based NDA technique for the assay of U, Pu and radionuclides in waste, based on licensed LANL TGS technology.
• Incorporates Tomographic Gamma Scanner (TGS), Segmented Gamma
Scanner (SGS) and Plutonium Isotopic Ratio Measurement capability in
one instrument.
• Automatic gamma-ray energy calibration using the Se-75 transmission
source.
• Transmission corrections are achieved using a Se-75 transmission
source to develop a 3-D spatial map of the attenuation coefficient of
the sample.
• Manual or automatic drum loading.
• Measurement time of typically less than one hour. Increased accuracy
and precision can be achieved by extending measurement time.
• Mobile operator control console which is compatible with both Drum
TGS and UGS for Cans,which can be local or remote from the
instrument.
• Accuracy is typically better than 10% for measurement of cans and 20%
for matrices with average density 2g/cm3. It is better than 10% for metal
scrap matrices.
www.antech-inc.com