Control Systems for Robots
Prof. Robert Marmelstein
CPSC 527 – Robotics
Spring 2010
Introduction to Robot Control



We want robots to do things that might otherwise be
done by intelligent, physical beings
Biological nervous systems are often thought of as
control systems for living organisms
To control a robot in this manner, we need to:






Define the state of the robot
Sense the state of the robot
Compare the state of the robot to a desired state
Decide what actions need to be taken to achieve the desired
state and issue the associated commands
Translate those command into physical action
Measure the effect of those physical actions
Robot State Description

Physical States:







Position
Orientation (pose)
Velocity
Acceleration
Sensor states
Actuator States
Internal States:



Plans
Tasks
Behaviors
Assumed vs. Actual
Control Engineering



Control engineering is the application of
mathematical techniques to the design of algorithms
and devices to control processes or pieces of
machinery.
It almost always requires a model of the entity that is
being controlled
If a system can be modeled by a set of linear
differential equations there are well understood
techniques for getting exact analytical solutions, and
so designing controllers so that the output of the
system is the required one
Example: Forced Spring

A forced spring can be modeled by a linear differential equation
k
m
b
x
2
F (t )  m
d x
dt
2
b
dx
dt
 kx
Real-World Systems




Unfortunately, most real-world
systems are non-linear in nature
Example: Pendulum
In these cases, the nonlinear system is
often approximated by a linear system
For the Pendulum, assume sin() ≈ ,
which yields:
Control System Components





Target Value – The desired operating point of the overall
system, which is speed.
Measured Value – The actual operating point of the system. It
is affected by external factors such as hills, and internal factors
such as the amount of fuel delivered to the engine.
Difference Value – This is the difference between the target
value and the measured value. Translates into feedback.
Control Input – This is the main adjusting point of the control
system. The amount of fuel delivered to the engine is the
primary control input to the cruise control
Control Algorithm – Determines how to best regulate the control
input to make the difference value as close to zero as
possible. It does this by periodically looking at the difference
value and adjusting the control input
Feedback Defined



Feedback: continuous monitoring of the sensors and reacting
to their changes.

Feedback control = self-regulation

Two kinds of feedback: positive and negative
Negative feedback acts to regulate the state/output of the
system

e.g., if too high, turn down, if too low, turn up

thermostats, toilets, bodies, robots...
Positive feedback acts to amplify the state/output of the
system

e.g., the more there is, the more is added

lynch mobs, stock market, ant trails...

Often results in system instability
Open Loop Controller





The Open Loop Controller (OLC) is the simplest kind
The controller sends an input signal to the plant
It does not compensate for disturbances that occur after the
control stage
Actual effects are assumed – not measured
No feedback to match actual to intended
Open Loop Controller (cont.)

The OLC is commonly used for behavior-based
systems




If a trigger condition is met , then the behavior is activated
Behavior is performed until the condition is no longer met
If the condition is not met, the (assumedly) some other
behavior is activated
You would likely use an OLC if you have no way of
measuring your operating point (e.g., the value you
are trying to control)
Problem with Open Loop Controllers


The effectiveness of OLCs are very context
dependent
The amount of force that is applied has different
effects dependent on the surface type
Closed Loop Controller


In Closed-loop control, the output is sensed and compared with
the reference. The resulting error signal is fed back to the
controller [feedback].
Components:



Reference – Desired State
Controller – Issues Commands
Plant – Actuator
Closed Loop Controller (cont.)


[Negative] Feedback keeps the operation of the system smooth and
stable
Closed Loop Controller issues:




How quickly will the system respond to error?
How long will it take the system to reach equilibrium?
What, if any, residual error will remain?
Under what conditions will the system become unstable?
Example of a Closed Loop Controller
Desired
Position
+
Error
-
Computation
(Brain)
Actuator Control
(Auto Pedals)
Velocity
(Engine Power)
Sensing
(Eyes)
Velocity
Input
Time
Velocity decreases as the
car gets closer to the
desired position
Velocity
Output
Actual
Position
Bang-Bang Controller (BBC)




The simplest type of closed-loop controller is the
Bang-Bang controller. It typically consists of two
states and a target value
The BBC typically monitors one item (quantity) of
interest—its job is to keep that quantity at a certain
target value
temp > target
If the quantity is too high or
low (vs. the target) the BBC
compensates to change it
OFF
ON
The system continually
transitions between states,
often abruptly
temp < target
Taking the Edge off Bang-Bang Control
with Hysteresis



Hysteresis provides a sort of "guard
band" around the desired set point of
the system.
In other words, when the temperature goes above (or
below) the desired control point, there is a margin
which needs to be exceeded before compensation is
applied
The result a lag which causes the system to run much
smoother, avoiding the jerkiness of a purely BangBang controller
Leveraging Hysteresis
Single Threshold System
(no hysteresis)
Use of temperature dead zone
to induce hysteresis
Closed Loop Controller Issues
JLJ Text – Fig 2.5
Low Gain – Sluggish
High Gain – Unstable
Proportional Integral Derivative (PID)
Controller




Closed loop controllers that only use
proportional control can easily become
unstable if the gain is too high or sluggish
if the gain is set too low
PID controllers help solve this problem
It use the measured error compute an
input to the Plant based on three distinct
controls: Proportional, Integral and
Derivative (see right)
Proportional control – Computed based on the actual error (times
a gain factor). Thus, The larger the error, the bigger correction
the control will make



Serves to control response time to error
For high gains or large errors, tends to overshoot and oscillate the
desired output
There is typically a steady state error that cannot be corrected
Proportional Integral Derivative (PID)
Controller

Integral control – Reduces steadystate error by adding (integrating) the
actual errors over time.
Once the error reaches a predetermined
threshold, the controller will compensates
 Too little can result in undershoot; too
much can result in overshoot
Derivative (D) control – Computed based of difference between
current and previous error. Thus, the output of this control is
proportional to the change in error





Prevents oscillations due to overshoot
Reduced settling time by giving a better dynamical response
Generally, this control has a positive effect
PID Controller (cont.)

The tunable factors are:





Kp – Proportional Gain factor
KI – Integral Gain Factor
KD – Differential Gain Factor
These factors are cross-coupled, so the performance of the
system cannot be optimized by tuning each factor
independently
Some systems can be engineered without all three PID
components




The P components is always required, but P controllers alone can
result in instability
PI is not accurate but converges quickly
PD converges relatively quickly reducing oscillations as it
approaches the goal.
PID accurately maintains a position, but isn’t very fast.
Helpful PID Terms

Gain(s) --The parameter(s) that determine the magnitude of the
system’s response.




Proportional Gain – When the value of the gain is proportional
to the error.
Damping – The process of systematically decreasing a system’s
fluctuations



Gain values determine whether or not the system stabilizes or
fluctuates.
Finding effective gains is a trial and error process, requiring testing
and recalibration.
A system is damped if it does not oscillate out of control.
Generally, the gains have to be adjusted for a system to be
damped
Steady State Error – The amount of error that remains after the
system has reached equilibrium
PID Controller (cont.)
• KP – Proportional Gain
• KI – Integral Gain
• KD – Derivative Gain
PID Controller Response Curve
Controlled
variable
Overshoot
Steady state error
%
Reference
Transient State
Settling time
Steady State
Time
PID Response Curve (cont.)


Rise Time (Tr) – The time for the plant output y to rise beyond
90% of the desired level for the first time
Overshoot – How much the peak level is higher than the steady
state, normalized against the steady state




The time required for the output to reach its maximum level is called
the Peak Time (Tp)
Settling Time (Ts) – The time it takes for the system to converge
to its steady state
Transient State – The period from the detection of error until its
approximate correction, resulting in the steady state
Steady-state Error – The difference between the steady-state
output and the desired output.
Effect of Increasing PID Factors
KP
KI
NT: No trend
KD
Control Performance – Proportional
Control
Source: CUNY – Dr. Jizhong Xiao
KP = 20
KP = 200
KP = 50
KP = 500
Control Performance – Integral Control
(KP = 100)
KI = 50
Source: CUNY – Dr. Jizhong Xiao
KI = 200
Control Performance – Derivative Control
(KP = 100, KI =200)
Source: CUNY – Dr. Jizhong Xiao
KD = 2
KD = 5
KD = 10
KD = 20
Optimizing Performance

PID Tuning – By Hand





PID tuning – By Design


Boost Kp until it oscillates
Boost KD to stop oscillation, back off Kp by 10%
Dial in KI to Hold position or velocity smooth
Trial and error
Zeigler-Nichols Method (next slide)
Other:


Work to minimize environmental interference and sensor
error (two are typically coupled)
Smart design helps too
Zeigler-Nichols Tuning Rule for PID
Controllers
Yields ~25%
overshoot and good
settling time
Why Care about the PID Controller?



Because PID Controllers are everywhere!
Due to its simplicity and excellent if not optimal performance in
many applications, PID controllers are used in more than 95%
of closed-loop industrial processes.
It can be tuned by operators without extensive background in
Controls, unlike many other modern controllers that are much
more complex but often provide only marginal improvement.


In fact, most PID controllers are tuned on-site.
The lengthy calculations for an initial guess of PID parameters
can often be circumvented if we know a few useful tuning rules.
This is especially useful when the system is unknown
Non-Linear Control





Linear controllers are generally valid only over small
operational ranges.
Hard non-linearity cannot even be approximated by
linear systems.
Model uncertainties can sometime be tolerated by the
addition of non-linear terms.
Non-linear systems often have multiple equilibrium
points, plus periodic, or chaotic attractors.
In these systems, small disturbances (even noise)
can induce radically different behaviors.
Control System Non-Linearity Issues

Saturation – Occurs when the
input signal to a certain device
exceeds the ability of the device
to process it



For output, saturation means that the required
compensation can no longer be applied to the control
system


Input – sensors
Output – motors
In general, it is good practice to limit the signal to the
saturation value in software
When an input reaches the saturation point, it no longer
provides a reliable estimate of the real world
Non-Linearity Issues (cont.)


Dead Zone – Because the sensitivity
of actuators is limited, not every
non-zero input will result in action.
The Dead Zone is the +/- region
above a zero (0) input that will result
in no actuator movement.
Backlash – Term describing actuator
hesitation and overshoot caused by
small gaps between motor gears

Can result in small, but unnecessary,
oscillations of the actuator position
Self-Balancing Robot Lab


Problem – Create a PID controller that will keep an
NXT robot balanced on two wheels
Use a light sensor to determine balance:




Light diminishes as it tilts backward
Light gets stronger as it tilts forward
Collect reference value when the robot is perfectly balanced
PID controller will use the light sensor data to
compute the compensation for the motors (plant)


Move backward if tilting back
Move forward if tilting forward
Self-Balancing Robot (Pics)
Light Sensor
[Simplified] PID Controller Algorithm
// Get Balance Reading for Light Sensor
midVal = Sensor_Read(LS_Port);
// Now Compute Power (PID) Value for Balancing Robot
while (true) {
lightVal = Sensor_Read(LS_Port);
error = lightVal – midVal;
diffErr = error – prevError;
intErr = intErr + error;
pVal = kp * error;
iVal = (ki*intErr)*dampFactor;
dVal = kd*diffErr;
prevErr = error;
power = (pVal+iVal+dVal)*scale;
MotorFWD(motorPorts, power);
}
Other Material



PID Controller for Dead Reckoning
CMU PID Tutorial
DePaul Self-Balancing Robots – Trials and
Tribulations