MetOne 7000 Overview

Download Report

Transcript MetOne 7000 Overview

MET ONE 7000 Series
Remote Airborne Particle Counters
Customer Name
Date
Presenter
Presenter Title
MET ONE 7000 Series
Copyright 2008 Hach Ultra Analytics – Page 2
Agenda
• MET ONE 7000 Series Overview
• Features and Benefits
• Part Numbers
Copyright 2008 Hach Ultra Analytics – Page 3
Introduction to the MET ONE 7000 Series
The MET ONE 7000 Series remote airborne particle counters, designed for ISO
21501 compliance, offers accurate, reliable, consistent and repeatable
continuous particle monitoring. With a sensitivity range of 0.3 to 10 µm, the MET
ONE 7000 Series is designed to meet the specific needs of cleanroom
operations within the aseptic or sterile manufacturing facilities in the Life
Science industry.
1.
Designed for ISO 21501 compliance, ensures
confidence in data accuracy, reliability and
repeatability.
2.
Flexible communication options and easy
installation features allow easy integration of the
remote counter with any FMS system.
3.
The counter offers the most advanced instrument
status and user notification indication feature
available in the industry, saving troubleshooting
and downtime related costs work.
Copyright 2008 Hach Ultra Analytics – Page 4
Introduction to MET ONE 7000 Series
• ISO 21501 compliant design
• Multiple I/O option
Multi-color status
indicator LED
• Built-in enhanced instrument status and user
notification indicator
• Long Life Laser™
• VHP tolerant flow path and optics
Optional remote indicator
light port
• Wall plate, umbilical cords and tubes with
quick connect fittings for ease of installation
and removal
• Up to 1000 sampling data storage
•
0.3 µm sensitivity, 0.1 or 1.0 cfm flow rate
• Built-in flow sensor option
• Remote status indicator light option Standard
2 channel, optional 4 channel
• Sealed enclosure with sealed connectors
• RH-Temp probe option
• Free set-up utility program
Copyright 2008 Hach Ultra Analytics – Page 5
Optional Relative HumidityTemperature
probe connection
Service port for instrument set-up
Also can be used for optional
remote display unit
(future enhancement)
First Counter Designed With ISO 21501
Compliant Capabilities
ISO 21501 is a new calibration standard replacing
ASTM F328 and other similar existing standards
• Accuracy in counting specific particle size
•
Significantly improved measurement repeatability
from counter to counter
•
Reliability in accurate identification of particle sizes of
interest that affect product quality and yield
Copyright 2008 Hach Ultra Analytics – Page 6
Flexible Communication Options
Save FMS integration costs,
repair and inventory related
costs with multiple
communications
• Serial I/O (RS-485 with Modbus
RTU or FX protocol)
• Ethernet
• Analog
• Wireless
RJ 45 sealed connector
for Ethernet, RS485 serial or
Analog I/O
Makes integration to any FMS easier
Copyright 2008 Hach Ultra Analytics – Page 7
Ease of Installation Features
• Easy installation with AC or DC input power options
– 100~230 VAC 50/60 Hz house power
– 24 VDC local power network
• Reduces re-installation time during routine
calibration and maintenance with DIP switch feature
for serial units
• Quick-connect type sealed vacuum connection
Quick connect type
vacuum connector
For ease of installation
AC or DC input power
option
Makes installation easier
DIP switch for setting
address of
RS485 serial I/O instrument
Makes installation and removal easier
Copyright 2008 Hach Ultra Analytics – Page 8
Ease of Installation Features
• Wall plate for terminating end-user cables
and tubing, reduces disruption to
connectivity during routine calibration
Wall Plate - Front
Makes installation and
removal of counter easier
• Umbilical with quick connect sealed
connectors protect counter from wash
down and make reinstallation easy
• Quick-connect type sealed vacuum
connection makes reinstallation during
routine calibration easy
User terminates wiring,
tubing at the rear end of
the wall plate
Makes installation easier
Copyright 2008 Hach Ultra Analytics – Page 9
Umbilical cords and
tubing supplied to
connect the counter
with wall plate
For ease of installation and
subsequent removal for routine
calibration and maintenance.
Ensure sealed connections
Installation Features - Standard Accessories
• Reduces initial installation time
• Minimizes removal and re-installation time during routine calibration and
maintenance
• Provides wash-down tolerance with sealed umbilical and tubing
Copyright 2008 Hach Ultra Analytics – Page 10
Item
Number
Description
1
MET ONE 7000 Counter
2
Mounting Plate
3, 4
Isokinetic Probe (0.1 or 1.0 cfm)
5
Wall Plate
6
Communication Cable with
Sealed RJ-45 Connectors
7
Power Cable AC or DC
8
Vacuum Tubing with Sealed
Quick Connectors
Enhanced Instrument Diagnostics
• Enhanced instrument status indication
reduce troubleshooting time and downtime
• Instrument can be diagnosed for flow,
sensor, communication failures, and
count alarm or count alert through
built-in or external light indicator
Steady Green = Normal (set by software or internal)
Flashing Red = Count Alarm (set by software or internal)
Flashing Yellow = Count Alert (set by software only)
One short flash, one long flash Blue = Flow Fail (set by software or internal)
Solid Blue = Sensor Fail (set by software or internal)
Flashing Blue (2 Hz) = Communication Failure
(internally set based on communication timeout)
Copyright 2008 Hach Ultra Analytics – Page 11
Built in or optional remote
multi-color status
indicator LED
MET ONE 7000 Series Setup Utility Program
• Reduce set-up time with the MET ONE 7000 Series
setup utility program
– Local Setup
– LAN Setup
– Data Display
• Reduce troubleshooting time
– Run MET ONE 7000 Series remote counters without
FMS software for troubleshooting
– Obtain instrument information such as model, serial
number and built in flow sensor
Copyright 2008 Hach Ultra Analytics – Page 12
Local Setup Screen Capture
Copyright 2008 Hach Ultra Analytics – Page 13
LAN Setup Screen Capture
Copyright 2008 Hach Ultra Analytics – Page 14
Data Display Screen Capture
Copyright 2008 Hach Ultra Analytics – Page 15
MET ONE 7000 Feature Summary
Features
Benefits
Designed for ISO 21501 calibration capability
Counter calibrated per ISO 21501 requirements measures particles
accurately, reliably and consistently
Flexible communication options
Easy to integrate with any FMS system due to flexible
communication features such as Serial Modbus, Ethernet Analog
and Wireless, and optional OPC server feature
Enhanced instrument status and user notification
indicator
Additional status indications provide faster troubleshooting and
reduces downtime
Long Life Laser
Average ~10 years – reduces cost of ownership
Ease of installation, removal and interchangeability
Shorter installation time and flexibility for removal and replacement
of counters for routine calibration work
Sealed enclosure and sealed connectors
Provides better sealing for use in wash-down areas
Flow Path and optics are VHP tolerant
Counter will not be damaged by accidental inclusion of VHP in the
sensor flow path during disinfecting process
Increased data storage
No loss of data during accidental communication or computer
problem
Hach Ultra MET ONE Brand
Quality, performance and service
Copyright 2008 Hach Ultra Analytics – Page 16
MET ONE 7000 Series Monetization
•
Reliability in accurate identification of particles due to ISO
21501 compliant design that improves product quality and
yield
•
Reduced troubleshooting time (labor), and less downtime
•
Standardized sensor irrespective of communication systems
saving integration cost, repair time, downtime and inventory
related costs
•
Reduced replacement parts cost and lower overall cost of
ownership
•
Reduced removal and re-installation cost during routine
calibration/maintenance work
•
Reduced risk of data loss due to communication disruption
Please use the monetization tab in the value selling document
Copyright 2008 Hach Ultra Analytics – Page 17
MET ONE 7000 Series Part Numbers
How to Order
20887_ 5 - N _ - _ _ -_
0 = DC Type cable
B = Type B Power Cord
D= Type D Power Cord
E= Type E Power Cord
G= Type G Power Cord
J= Type J Power Cord
D = 24 VDC Input Power
A = 100~230 VAC 50/60 HZ Input Power
A = Analog 4~20 mA
E = Ethernet
S = Serial RS485
F = with flow measurement
N = without flow measurement
N = No Built-in Pump
5 = 0.5µm Minimum sensitivity
0 = 0.1 cfm
1 = 1.0 cfm
208871 5 - NF - ED - 0 (Example)
208871 5 - NF - SA - B (Example)
Copyright 2008 Hach Ultra Analytics – Page 18
Standard Shipment Includes
Copyright 2008 Hach Ultra Analytics – Page 19
Item
Number
Description
1
MET ONE 7000 Counter
2
Mounting Plate
3, 4
Isokinetic Probe (0.1 or 1.0 cfm)
5
Wall Plate
6
Communication Cable with
Sealed RJ-45 Connectors
7
Power Cable AC or DC
8
Vacuum Tubing with Sealed
Quick Connectors
MET ONE 7000 Series