Presentazione di PowerPoint

Download Report

Transcript Presentazione di PowerPoint

PowerScale
10-50kVA
Ed. 02.02.2011
Maximize your availability
www.newavenergy.com
Contents
• Range
• Features and Performance
• Mechanical Construction
• Battery Configuration
• External Batteries – Battery Cabinet
• Connectivity
• Options and accessories
www.newaveups.com
02.02.2011
2
Range
Technology : On-Line, transformer less
Power range : 10 ,15, 20, 25,30 ,40,50 kVA (3ph/3ph)
Rated at PF : cosphi 0.9
Type A
Type B
10kVA
10kVA
15kVA
15kVA
20kVA
20kVA
25kVA
Type C
25kVA
30kVA
40kVA
50kVA
345 x 720 x 710
345 x 1045 x 710
440 x 1400 x 910
60-62-64kg
88-90-92-94kg
135-145-150-155kg
www.newaveups.com
02.02.2011
3
Features and performance
• Generalities
• LCD Display
• Input PFC
• Input THDI
• Efficiency
• Active Power vs cosphi
www.newaveups.com
02.02.2011
4
Features and performance
 True on-line double conversion (VFI)
Generalities
 Power Factor 0.9
 High efficiency (up to 95.5%)
 Input PFC: 0.99 @ 100% load
 Input THDi < 3 %
 Parallelable up to 20 units
Cab C
Cab B
Cab A
 Electronic and manual bypass
 Manual/Automatic Battery test
 Fan speed temperature regulated
 Easy to install, service and manoeuvre
 Flexible battery autonomy space within
3 different cabinets size (A,B,C)
 Single or Dual input feed
 RS 232 + 4 potential free input contacts
 SNMP card slot / Pot. Free Output card slot
 Multi language LCD display E/S/D/F/P
 Wide Input voltage windows
<@100% load(-23% / +15%)
<@80% load (-30% / +15%)
<@60% load (-40% / +15%)
www.newaveups.com
02.02.2011
5
Features and performance
LCD Display
LCD Display
LINE 2
LINE 1
ON / OFF
BY PASS
INV
BATTERY
RESET
ENTER
ON / OFF
ALARM
Most important info available at first glance
www.newaveups.com
02.02.2011
6
Features and performance
Input PFC
Advanced Booster PFC circuit to provide
near-unity Input PF even with partial loads.
1
0.96
Input PF (%)
0.9
0.985
0.99
0.99
0.8
0.7
0.6
Benefits:
• No phase compensation filter
required
• Respect power grid
regulations
• Energy savings
Reduced TCO
0.5
25%
50%
75%
100%
Load
(%)
www.newaveups.com
02.02.2011
7
Features and performance
THDi
Input THD versus load
Advanced Booster PFC circuit to provide
Flat THDi Curve even with partial loads.
Benefits:
• No gen-set oversizing
• Small cable/fuses/breakers
size
• No extra heating of
transformers
 Unique electrical performance
 Reduced TCO
www.newaveups.com
02.02.2011
8
Features and performance
Efficiency
Flat Efficiency Graph
Results in low losses at PARTIAL and FULL load
Redundant UPS Systems operating typically at 25-75%
of the rated load.
 Energy Savings
 Reduced TCO
www.newaveups.com
02.02.2011
9
Mechanical Construction
Overview: Cabinet A
LCD
Display
Air
inlets
• SNMP Card
• Pot.free output
contacts
(optional)
• RS232
• Pot.free
Input
contacts
• Multidrop
Parallel kit
By-pass fuse
Battery fuse
Rectifier fuse
Castors
Manual
By-pass
UPS
disconnect
I/O
connection
www.newaveups.com
02.02.2011
10
Mechanical Construction
Overview: Cabinet A
Display
Board
CPU
board
• Rectifier
• Booster
• Battery
charger
•Inverter
Battery
bank
www.newaveups.com
02.02.2011
11
Mechanical Construction
Overview: Cabinet B
LCD
Display
• SNMPCard
• Pot.free output contacts
(optional)
• RS232
• Pot.free
Input
contacts
• Multidrop
Parallel Kit
Air
inlets
Battery fuse
By-pass fuse
Rectifier fuse
Manual
By-pass
Castors
UPS
disconnect
I/O
connection
www.newaveups.com
02.02.2011
12
Mechanical Construciton
Overview: Cabinet B
Display
Board
CPU
board
• Rectifier
• Booster
• Battery
charger
•Inverter
Battery
bank
www.newaveups.com
02.02.2011
13
Mechanical Construciton
Overview: Cabinet C
LCD
Display
Removeable
Front Panel
No Access from
Rear Side
Air
inlets
Castors
www.newaveups.com
02.02.2011
14
Mechanical Construciton
Overview: Cabinet C
RS 232
Pot.free
Input
Contacts
Multidrop
Parall. Kit
• SNMP
• Card and
Pot. Free
output
contacts
(optional)
Rectifier
fuse
By-pass fuse
Battery fuse
Manual
By-pass
UPS
disconnect
I/O
connection
www.newaveups.com
02.02.2011
15
Battery Configuration
Battery shelves, trays and links
Type A
Type B
Type C
Power Range
kVA/kW
10/9
15/13.5
20/18
10/9
15/13.5
20/18
25/22.5
25/22.5
30/27
40/36
50/45
Maximum
Battery Capacity
1 x 48 x 7/9Ah
2 x 48 x 7/9Ah
3 x 48 x 7/9Ah
1 x 48 x 28Ah
Battery shelves
and trays
Included
Included
Optional:
Battery links
Optional:
Optional:
Optional:
1 x 48 x 7/9Ah 04-0136
1 x 48 x 7/9Ah 04-0136
2 x 48 x 7/9Ah 04-0150
2 x 48 x 7/9Ah 04-1473
3 x 48 x 7/9Ah 04-1472
1 x 48 x 28Ah 04-1474
2 x 48 x 7/9Ah 04-1475
3 x 48 x 7/9Ah 04-1476
1 x 48 x 28Ah 04-1477
www.newaveups.com
02.02.2011
16
Battery Configuration
Battery shelves & trays
Cabinet C (25, 30,40,50kVA)
Standard Cabinet C
2 Shelves are delivered with
the empty cabinet
Additional Shelves and Trays
are OPTIONAL.
Possible configurations:
• 2 x 48 x 7/9Ah
• 3 x 48 x 7/9Ah
• 1 x 48 x 28Ah
Shelves
(Standard)
www.newaveups.com
02.02.2011
17
Battery Configuration
Battery shelves & trays
Cabinet C (25, 30,40,50kVA)
OPTION 04-1475:
Battery shelves and trays for
2 x 48 x 7/9Ah
Kit consisting of:
2 x shelves
16 x trays
(6 x 7/9Ah batt / tray)
www.newaveups.com
02.02.2011
18
Battery Configuration
Battery shelves & trays
Cabinet C (25, 30,40,50kVA)
OPTION 04-1476:
Battery shelves and trays for
3 x 48 x 7/9Ah
Kit consisting of:
4 x shelves
24 x trays
(6 x 7/9Ah batt / tray)
www.newaveups.com
02.02.2011
19
Battery Configuration
Battery shelves & trays
Cabinet C (25, 30,40,50kVA)
OPTION 04-1477:
Battery shelves and trays for
1 x 48 x 28Ah
Kit consisting of:
2 x shelves
16 x trays
(3 x 28Ah batt / tray)
www.newaveups.com
02.02.2011
20
Battery Configuration
Caracteristics (1)
Source:
PowerScale Product Specifications
Doc: 04-1206_S10_NW_TDSPS_10-50kVA_GB_101021 (2)
www.newaveups.com
02.02.2011
21
Battery Configuration
Caracteristics (2)
www.newaveups.com
02.02.2011
22
Battery Configuration
How to order INTEGRATED Batteries from Newave
Type of Batteries offered by Newave SA
7Ah: Panasonic (normal life)
9Ah: YUASA (normal life)
28Ah: Panasonic (long life 10Y)
Principles:
1.
Subsidiaries and Partners calculate
the exact number of battery per
string that the application requests
and order number of blocks
accordingly (minimal number acc to
Product Specifications)
2.
Newave delivers the UPS with
integrated batteries mounted
and tested, as requested
3.
Battery blocks in PowerScale
price list include shelves,
trays and battery links (items
04-1203; 04-1204; 04-1472; 041473; 04-1474)
PO-Form detail
Set Battery Autonomy:
mins.
Number of Battery Strings:
Number of Battery Blocks:
(per string)
Ah:
www.newaveups.com
02.02.2011
23
Battery Configuration
Autonomy Table 10kVA
Powerscale 10kVA, 9kW
Autonomy (min)
6
8
10
12
15
18
20
22
25
30
35
40
60
Min. Nr of Batt Cab A
Min. Nr of Batt Cab B
Load Power
6kW
8kW
9kW
7Ah batt 9Ah batt 7Ah batt 9Ah batt 7Ah batt 9Ah batt
1 x 24
1 x 20
1 x 32
1 x 22
1 x 34
1 x 24
1 x 28
1 x 22
1 x 38
1 x 26
1 x 42
1 x 28
1 x 32
1 x 24
1 x 46
1 x 32
1 x 48
1 x 34
1 x 40
1 x 28
2 x 26
1 x 36
2 x 30
1 x 40
1 x 48
1 x 32
2 x 32
1 x 42
2 x 36
1 x 48
2 x 28
1 x 38
2 x 36
1 x 48
2 x 40
2 x 28
2 x 30
1 x 40
2 x 40
2 x 28
2 x 44
2 x 30
2 x 32
1 x 44
2 x 42
2 x 30
2 x 48
2 x 32
2 x 36
1 x 48
2 x 48
2 x 32
n.a.
2 x 36
2 x 40
2 x 28
n.a.
2 x 38
n.a.
2 x 42
2 x 46
2 x 32
n.a.
2 x 42
n.a.
2 x 48
n.a.
2 x 36
n.a.
2 x 48
n.a.
n.a.
n.a.
2 x 48
n.a.
n.a.
n.a.
n.a.
16 blocks
20 blocks
24 blocks
16 blocks
20 blocks
24 blocks
Cabinet A: max 1 x 48 x 7/9Ah batteries
Cabinet B: max 2 x 48 x 7/9Ah batteries
Note: Backup times are approximate and may vary with battery type, configuration, battery age, temperature etc.
www.newaveups.com
02.02.2011
24
Battery Configuration
Autonomy Table 15kVA
Powerscale 15kVA, 13.5kW
Autonomy (min)
6
8
10
12
15
18
20
25
30
35
40
60
Min. Nr of Batt Cab A
Min. Nr of Batt Cab B
10kW
7Ah batt 9Ah batt
1 x 40
1 x 28
1 x 48
1 x 34
2 x 28
1 x 40
2 x 34
1 x 48
2 x 40
2 x 28
2 x 46
2 x 32
2 x 48
2 x 36
n.a.
2 x 40
n.a.
2 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
24 blocks
24 blocks
Load Power
12kW
7Ah batt 9Ah batt
1 x 48
1 x 32
2 x 28
1 x 40
2 x 34
1 x 48
2 x 40
2 x 28
2 x 48
2 x 32
n.a.
2 x 38
n.a.
2 x 40
n.a.
2 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
30 blocks
30 blocks
13.5kW
7Ah batt 9Ah batt
1 x 34
2 x 34
1 x 42
2 x 40
1 x 48
2 x 48
n.a.
2 x 34
n.a.
2 x 42
n.a.
2 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
34 blocks
34 blocks
Cabinet A: max 1 x 48 x 7/9Ah batteries
Cabinet B: max 2 x 48 x 7/9Ah batteries
Note: Backup times are approximate and may vary with battery type, configuration, battery age, temperature etc.
www.newaveups.com
02.02.2011
25
Battery Configuration
Autonomy Table 20kVA
Powerscale 20kVA, 18kW
Autonomy (min)
4
6
7
8
10
11
12
15
17
18
20
25
30
35
Min. Nr of Batt Cab A
Min. Nr of Batt Cab B
12kW
7Ah batt 9Ah batt
1 x 48
1 x 32
2 x 28
2 x 34
1 x 40
1 x 48
2 x 40
2 x 28
2 x 48
2 x 32
n.a.
n.a.
2 x 38
n.a.
2 x 40
n.a.
2 x 48
n.a.
n.a.
n.a.
n.a.
30 blocks
24 blocks
Load Power
16kW
7Ah batt 9Ah batt
1 x 48
2 x 32
1 x 44
1 x 48
2 x 38
2 x 46
2 x 32
2 x 48
n.a.
2 x 36
n.a.
2 x 42
n.a.
2 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
40 blocks
32 blocks
18kW
7Ah batt 9Ah batt
2 x 36
1 x 46
2 x 38
2 x 42
2 x 48
2 x 36
n.a.
2 x 38
n.a.
2 x 40
n.a.
2 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
46 blocks
36 blocks
Cabinet A: max 1 x 48 x 7/9Ah batteries
Cabinet B: max 2 x 48 x 7/9Ah batteries
Note: Backup times are approximate and may vary with battery type, configuration, battery age, temperature etc.
www.newaveups.com
02.02.2011
26
Battery Configuration
Autonomy Table 25kVA
Powerscale 25kVA, 22.5kW
Autonomy (min)
6
8
10
12
13
15
18
20
22
24
25
27
28
29
31
32
Min. Nr of Batt Cab B
Min. Nr of Batt Cab C
Load Power
16kW
20kW
7Ah batt 9Ah batt 28Ah batt 7Ah batt 9Ah batt 28Ah batt
2 x 32
1 x 44
2 x 40
2 x 40**
2 x 38
1 x 48
2 x 48
2 x 40**
2 x 46
2 x 32
3 x 40**
2 x 40
2 x 48
2 x 36
3 x 44
2 x 44
3 x 48
2 x 48
3 x 42
2 x 44
n.a.
3 x 40**
3 x 48
2 x 48
1 x 34
n.a.
3 x 42
1 x 40
n.a.
3 x 36
n.a.
3 x 46
n.a.
3 x 38
1 x 40
n.a.
3 x 48
1 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
3 x 42
1 x 44
n.a.
n.a.
n.a.
n.a.
3 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
1 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
32 blocks
40 blocks
32 blocks
40 blocks
7Ah batt
2 x 46
2 x 48
3 x 46
3 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
22.5kW
9Ah batt 28Ah batt
2 x 46
2 x 48
3 x 46
3 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
46 blocks
46 blocks
1 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
Cabinet B: max 2 x 48 x 7/9Ah batteries
Cabinet C: max 3 x 48 x 7/9Ah batteries
Note: Backup times are approximate and may vary with battery type, configuration, battery age, temperature etc.
www.newaveups.com
02.02.2011
27
Battery Configuration
Autonomy Table 30kVA
Powerscale 30kVA, 27kW
Autonomy (min)
6
7
8
10
12
13
15
18
20
22
24
25
27
28
29
31
32
Min. Nr of Batt Cab C
7Ah batt
2 x 40
Load Power
20kW
24kW
9Ah batt 28Ah batt 7Ah batt 9Ah batt 28Ah batt
2 x 48
7Ah batt
3 x 36
2 x 48
3 x 44
3 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
27kW
9Ah batt 28Ah batt
3 x 28
2 x 40
2 x 44
2 x 48
3 x 42
3 x 46
3 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
20 blocks
2 x 48
1 x 40
1 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
3 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
3 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
24 blocks
1 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
3 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
3 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
28 blocks
1 x 28
1 x 30
1 x 36
1 x 42
1 x 44
1 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
Cabinet C: max 3 x 48 x 7/9Ah batteries
www.newaveups.com
02.02.2011
28
Battery Configuration
Autonomy Table 40kVA
Powerscale 40kVA, 36kW
Autonomy (min)
6
7
8
9
10
12
13
15
16
18
20
Min. Nr of Batt Cab C
Load Power
25kW
32kW
7Ah batt 9Ah batt 28Ah batt 7Ah batt 9Ah batt 28Ah batt
2 x 48
2 x 32
2 x 48
1 x 26
3 x 48
1 x 32
3 x 40
2 x 40
n.a.
1 x 34
n.a.
3 x 48
2 x 48
1 x 34
n.a.
1 x 40
n.a.
3 x 38
n.a.
3 x 48
1 x 48
n.a.
3 x 40
1 x 40
n.a.
n.a.
n.a.
n.a.
3 x 44
n.a.
n.a.
n.a.
n.a.
3 x 48
1 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
26 blocks
32 blocks
36kW
7Ah batt
3 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
9Ah batt 28Ah batt
2 x 48
3 x 36
1 x 36
1 x 42
3 x 46
1 x 44
3 x 48
1 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
36 blocks
Cabinet C: max 3 x 48 x 7/9Ah batteries
www.newaveups.com
02.02.2011
29
Battery Configuration
Autonomy Table 50kVA
Powerscale 50kVA, 40kW
Autonomy (min)
6
7
8
9
10
12
13
15
16
18
20
Min. Nr of Batt Cab C
Load Power
35kW
40kW
7Ah batt 9Ah batt 28Ah batt 7Ah batt 9Ah batt 28Ah batt
3 x 48
2 x 48
1 x 34
n.a.
n.a.
n.a.
3 x 40
1 x 40
n.a.
3 x 40
1 x 40
n.a.
3 x 44
n.a.
n.a.
3 x 48
1 x 48
n.a.
3 x 44
1 x 48
n.a.
n.a.
n.a.
n.a.
3 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
34 blocks
40 blocks
45kW
7Ah batt
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
9Ah batt 28Ah batt
3 x 46
3 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
44 blocks
1 x 44
1 x 48
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
Cabinet C: max 3 x 48 x 7/9Ah batteries
www.newaveups.com
02.02.2011
30
External Batteries – Battery Cabinet
Battery Cabinet
In case of external battery requirment, an external battery
cabinet will be made available in March 2011.
More information will be available early 2011
www.newaveups.com
02.02.2011
31
Connectivity
Standard - included
Optional
• RS232 on Sub-D9 port
A. SNMP/USHA Card (Slot)
• Input Dry Contacts:
1.
2.
3.
4.
5.
Remote shut down
Generator ON
Programable Input: Customer IN1
Temp Sensor for Battery
12VDC Source
• RJ 45 for Multidrop
B. Optional Card
(Dry contact and USB port: Item nr 00-9737)
• Output Dry Contacts:
1.Common Alarm
2.Load on Bypass
3.Battery low
4.Load on Inverster
5.Mains Failure
• USB port
www.newaveups.com
02.02.2011
32
Options and Accessories
Available in price list
 SNMP slot card (web enabled)
 Shutdown software
 Potential free output contact slot card, including USB port
 Parallel kit (one additionnel PCB + one parallel adapter)
 Parallel cables of different lenghts
 Back feed protection
 Temperature probe
On special request
 Emergency Shut Down
 I/O Transformer for galvanic isolation or voltage
adaptation, special I/O configuration
www.newaveups.com
02.02.2011
33
Sales Availability
Ex Works Availability
 10kVA
Cabinet
 15kVA
Cabinet
 20kVA
Cabinet
 25kVA
Cabinet


25kVA
30,40,50kVA

Battery Cabinet
A and B
A and B
A and B
B
Cabinet C
Cabinet C
January 2011
March 2011
Documentation
1.
2.
3.
4.
5.
6.
Sales Presentation
Product Flyer
Technical Specifications
Price List
PO-Form
User Manual (at delivery)
www.newaveups.com
02.02.2011
34
www.newaveups.com
02.02.2011
35